Personalized Stem Length Optimization in Hip Replacement: A Microscopic Perspective on Bone—Implant Interaction

Total hip replacement (THR) surgery involves the removal of necrotic tissue and the replacement of the natural joint with an artificial hip joint. The demand for THR is increasing due to population aging and prolonged life expectancies. However, the uniform length and shape of artificial hip joints can cause stress shielding, leading to implant loosening and femoral fractures. These issues arise because these designs fail to account for the unique anatomical and biomechanical characteristics of individual patients. Therefore, this study proposes and validates a method to optimize stem length by considering bone microstructure and daily load. The results demonstrated that the optimal stem length varies with loading conditions and significantly reduces stress in the cortical bone while maintaining an appropriate strain energy in the cancellous bone, thereby preventing bone loss. These findings underscore the importance of patient-specific stem design for improving implant stability and clinical outcomes.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2024-10-27
DOI
https://doi.org/10.3390/bioengineering11111074
Citations
3
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Personalized Stem Length Optimization in Hip Replacement: A Microscopic Perspective on Bone—Implant Interaction

Jung Jin Kim, Sumin Kim, Jun Won Choi
3 citations
Bioengineering
Orthopaedic implants and arthroplasty
1.72
article

Personalized Stem Length Optimization in Hip Replacement: A Microscopic Perspective on Bone—Implant Interaction

Jung Jin Kim, Sumin Kim, Jun Won Choi
article en
3 citations

Abstract

Total hip replacement (THR) surgery involves the removal of necrotic tissue and the replacement of the natural joint with an artificial hip joint. The demand for THR is increasing due to population aging and prolonged life expectancies. However, the uniform length and shape of artificial hip joints can cause stress shielding, leading to implant loosening and femoral fractures. These issues arise because these designs fail to account for the unique anatomical and biomechanical characteristics of individual patients. Therefore, this study proposes and validates a method to optimize stem length by considering bone microstructure and daily load. The results demonstrated that the optimal stem length varies with loading conditions and significantly reduces stress in the cortical bone while maintaining an appropriate strain energy in the cancellous bone, thereby preventing bone loss. These findings underscore the importance of patient-specific stem design for improving implant stability and clinical outcomes.

BioengineeringVol. 11(11)
Keimyung University (KR)
National Research Foundation, National Research Foundation of Korea
Openalex Percentile: Top 15%
Orthopaedic implants and arthroplasty
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.