Five-year outcomes with self-expanding versus balloon-expandable transcatheter aortic valve replacement in patients with left ventricular systolic dysfunction

Abstract Background The importance of transcatheter heart valve (THV) design on clinical outcome in patients with aortic stenosis (AS) and left ventricular (LV) systolic dysfunction remains unknown. Objectives We aimed to compare 5-year outcomes of patients with severe AS and reduced LV ejection fraction (LVEF), undergoing transcatheter aortic valve replacement (TAVR) with balloon-expandable vs. self-expanding THVs. Methods In an institutional TAVR registry, patients with LVEF <50% who underwent TAVR with either balloon-expandable or self-expanding THVs were included. A 1:1 propensity-score matching was performed to account for baseline differences between groups. Results A total of 759 patients were included between August 2007 and December 2022, and propensity-score matching resulted in 134 pairs. Technical success was achieved in over 85% of patients, and was similar in both groups. Self-expanding THVs were associated with a lower mean transvalvular gradient (7.1 ± 3.7 mmHg vs. 9.9 ± 4.3 mmHg; P <0.001) and a higher incidence of ³mild-to-moderate paravalvular regurgitation (36.3% vs. 11.3%; P <0.001) compared to balloon-expandable THVs. At 5 years, patients treated with a self-expanding THV had higher all-cause mortality than those with a balloon-expandable THV (67.8% vs. 55.8%, Adjusted Hazard Ratio: 1.44; 95% CI: 1.02-2.03; P = 0.037). There were no significant differences in other clinical outcomes up to 5 years between groups. Conclusions In the setting of LV systolic dysfunction, patients treated with a self-expanding THV had higher risk of 5-year mortality compared to patients treated with a balloon-expandable THV.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1863
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Five-year outcomes with self-expanding versus balloon-expandable transcatheter aortic valve replacement in patients with left ventricular systolic dysfunction

David Reineke, Daijiro Tomii, Daryoush Samim, Thomas Pilgrim et al.
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Five-year outcomes with self-expanding versus balloon-expandable transcatheter aortic valve replacement in patients with left ventricular systolic dysfunction

David Reineke, Daijiro Tomii, Daryoush Samim, Thomas Pilgrim, Jonas Lanz, Annette Maznyczka, Dik Heg, Stephan Windecker, Stefan Stortecky, Taishi Okuno, M Nakase
article en

Abstract

Abstract Background The importance of transcatheter heart valve (THV) design on clinical outcome in patients with aortic stenosis (AS) and left ventricular (LV) systolic dysfunction remains unknown. Objectives We aimed to compare 5-year outcomes of patients with severe AS and reduced LV ejection fraction (LVEF), undergoing transcatheter aortic valve replacement (TAVR) with balloon-expandable vs. self-expanding THVs. Methods In an institutional TAVR registry, patients with LVEF <50% who underwent TAVR with either balloon-expandable or self-expanding THVs were included. A 1:1 propensity-score matching was performed to account for baseline differences between groups. Results A total of 759 patients were included between August 2007 and December 2022, and propensity-score matching resulted in 134 pairs. Technical success was achieved in over 85% of patients, and was similar in both groups. Self-expanding THVs were associated with a lower mean transvalvular gradient (7.1 ± 3.7 mmHg vs. 9.9 ± 4.3 mmHg; P <0.001) and a higher incidence of ³mild-to-moderate paravalvular regurgitation (36.3% vs. 11.3%; P <0.001) compared to balloon-expandable THVs. At 5 years, patients treated with a self-expanding THV had higher all-cause mortality than those with a balloon-expandable THV (67.8% vs. 55.8%, Adjusted Hazard Ratio: 1.44; 95% CI: 1.02-2.03; P = 0.037). There were no significant differences in other clinical outcomes up to 5 years between groups. Conclusions In the setting of LV systolic dysfunction, patients treated with a self-expanding THV had higher risk of 5-year mortality compared to patients treated with a balloon-expandable THV.

European Heart JournalVol. 45(Supplement_1)
University of Bern (CH)
Openalex Percentile: Top 65%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.