High time resolution quantification of PM2.5 oxidative potential at a Central London roadside supersite

The oxidative potential (OP) of airborne particulate matter (PM) is gaining increasing attention as a health-relevant metric to describe the capacity of PM to promote oxidative stress and cause adverse health effects. To date, most OP studies use filter-based approaches to sample PM and quantify OP, which have relatively poor time resolution (∼24 h) and underestimate the contribution of reactive components to OP due to the time delay between sample collection and analysis. To address this important limitation, we have developed a novel instrument which uses a direct-to-reagent sampling approach, providing robust, continuous, high time resolution (5 min) OP quantification, hence overcoming analytical limitations of filter-based techniques. In this study, we deployed this instrument in the Marylebone Road Air Quality Monitoring Station in London, UK, alongside a broad suite of high time resolution PM<sub>2.5</sub> composition measurements for three months continuous measurement during Summer 2023. High time resolution OP quantification reveals dynamic changes in volume-normalised (OP<sub>v</sub>) and mass normalised (OP<sub>m</sub>) OP evolving over ∼hourly timescales, observed at an average PM<sub>2.5</sub> mass concentration of 7.1 ± 4.2 µg m<sup>-3</sup>, below the WHO interim 4 target of 10 µg m<sup>-3</sup>. In addition, high time resolution data facilitates directional analysis, allowing us to determine the influence of wind speed and wind direction on OP, and the identification of PM<sub>2.5</sub> chemical components and sources which drive dynamic changes in OP; this includes traffic emissions, as well as emissions from the London Underground into the ambient airshed. These results demonstrate the capacity of high time resolution measurements to provide new insights into the temporal evolution of OP, as well as the composition and emission sources which drive OP, developing our understanding of the characteristics of PM<sub>2.5</sub> which may promote adverse health impacts.

Authors

Institutions

Publication Details

Journal
Environment International
Published
2024-10-28
DOI
https://doi.org/10.1016/j.envint.2024.109102
Citations
13
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
4.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High time resolution quantification of PM2.5 oxidative potential at a Central London roadside supersite

Markus Kalberer, Frank J. Kelly, Steven J. Campbell, David C. Green et al.
13 citations
Environment International
Air Quality and Health Impacts
4.09
article

High time resolution quantification of PM2.5 oxidative potential at a Central London roadside supersite

Markus Kalberer, Frank J. Kelly, Steven J. Campbell, David C. Green, Gang Chen, Alexandre Barth, Anja H. Tremper, Max Priestman, David Ek, Shuming Gu
article en
13 citations

Abstract

The oxidative potential (OP) of airborne particulate matter (PM) is gaining increasing attention as a health-relevant metric to describe the capacity of PM to promote oxidative stress and cause adverse health effects. To date, most OP studies use filter-based approaches to sample PM and quantify OP, which have relatively poor time resolution (∼24 h) and underestimate the contribution of reactive components to OP due to the time delay between sample collection and analysis. To address this important limitation, we have developed a novel instrument which uses a direct-to-reagent sampling approach, providing robust, continuous, high time resolution (5 min) OP quantification, hence overcoming analytical limitations of filter-based techniques. In this study, we deployed this instrument in the Marylebone Road Air Quality Monitoring Station in London, UK, alongside a broad suite of high time resolution PM<sub>2.5</sub> composition measurements for three months continuous measurement during Summer 2023. High time resolution OP quantification reveals dynamic changes in volume-normalised (OP<sub>v</sub>) and mass normalised (OP<sub>m</sub>) OP evolving over ∼hourly timescales, observed at an average PM<sub>2.5</sub> mass concentration of 7.1 ± 4.2 µg m<sup>-3</sup>, below the WHO interim 4 target of 10 µg m<sup>-3</sup>. In addition, high time resolution data facilitates directional analysis, allowing us to determine the influence of wind speed and wind direction on OP, and the identification of PM<sub>2.5</sub> chemical components and sources which drive dynamic changes in OP; this includes traffic emissions, as well as emissions from the London Underground into the ambient airshed. These results demonstrate the capacity of high time resolution measurements to provide new insights into the temporal evolution of OP, as well as the composition and emission sources which drive OP, developing our understanding of the characteristics of PM<sub>2.5</sub> which may promote adverse health impacts.

Environment InternationalVol. 193
University of Basel (CH), MRC Centre for Environment and Health, Imperial College London (GB)
Medical Research Council
Openalex Percentile: Top 6%
Air Quality and Health Impacts
4.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.