Smoke control and temperature distribution of tunnel fires under longitudinal ventilation combined with shaft exhaust

Longitudinal segmental smoke exhaust is often used for fire tunnels longer than 5 km. With the combined effect of longitudinal ventilation in the main tunnel and fan suction in the exhaust shaft, the smoke exhaust path is different from that of a traditional single-tube tunnel. Findings reported in the literature is insufficient to support the rapid development of extra-long road tunnels. In this paper, a numerical model was established by FDS (Fire Dynamics Simulator), and a 1:15 model test platform was built for verification. The effects of different longitudinal velocities, exhaust velocities, bifurcation angles, and exhaust shaft slopes on tunnel fires were analyzed for the longitudinal ventilation combined with shaft exhaust smoke evacuation mode (LVSE). The results show that when the exhaust velocity is greater than 4.5 m/s, increasing the exhaust velocity has a limited effect on reducing the smoke length downstream of the exhaust shaft. The bifurcation angle has a significant effect on the velocity distribution in the ventilation shaft and the main tunnel. When the bifurcation angle is less than 45°, the airflow in the main tunnel is more likely to enter the exhaust shaft, and the velocity in the exhaust shaft is more than 5 m/s. It is more favorable to reduce the smoke length when the slope of the exhaust shaft is not less than 7 %. The high-temperature flue gas collects and forms a vortex near the vent under the LVSE mode, which makes the temperature decay rate slower than that when only longitudinal ventilation is used. The temperature decay model for the LVSE mode is obtained. This study is intended to provide a reference basis for the fire safety design of extra-long road tunnels under the LVSE mode.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2024-10-28
DOI
https://doi.org/10.1016/j.csite.2024.105365
Citations
9
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
3.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smoke control and temperature distribution of tunnel fires under longitudinal ventilation combined with shaft exhaust

Liangliang Tao, Yumin Wen, Yanhua Zeng, Xinyue Zhang et al.
9 citations
Case Studies in Thermal Engineering
Fire dynamics and safety research
3.28
article

Smoke control and temperature distribution of tunnel fires under longitudinal ventilation combined with shaft exhaust

Liangliang Tao, Yumin Wen, Yanhua Zeng, Xinyue Zhang, Weiling Ma
article en
9 citations

Abstract

Longitudinal segmental smoke exhaust is often used for fire tunnels longer than 5 km. With the combined effect of longitudinal ventilation in the main tunnel and fan suction in the exhaust shaft, the smoke exhaust path is different from that of a traditional single-tube tunnel. Findings reported in the literature is insufficient to support the rapid development of extra-long road tunnels. In this paper, a numerical model was established by FDS (Fire Dynamics Simulator), and a 1:15 model test platform was built for verification. The effects of different longitudinal velocities, exhaust velocities, bifurcation angles, and exhaust shaft slopes on tunnel fires were analyzed for the longitudinal ventilation combined with shaft exhaust smoke evacuation mode (LVSE). The results show that when the exhaust velocity is greater than 4.5 m/s, increasing the exhaust velocity has a limited effect on reducing the smoke length downstream of the exhaust shaft. The bifurcation angle has a significant effect on the velocity distribution in the ventilation shaft and the main tunnel. When the bifurcation angle is less than 45°, the airflow in the main tunnel is more likely to enter the exhaust shaft, and the velocity in the exhaust shaft is more than 5 m/s. It is more favorable to reduce the smoke length when the slope of the exhaust shaft is not less than 7 %. The high-temperature flue gas collects and forms a vortex near the vent under the LVSE mode, which makes the temperature decay rate slower than that when only longitudinal ventilation is used. The temperature decay model for the LVSE mode is obtained. This study is intended to provide a reference basis for the fire safety design of extra-long road tunnels under the LVSE mode.

Case Studies in Thermal EngineeringVol. 65
Southwest Jiaotong University (CN)
Openalex Percentile: Top 8%
Fire dynamics and safety research
3.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.