AI-enabled automated cardiac chambers volumetry in non-contrast ECG-gated cardiac scans vs. non-contrast non-gated lung scans

Abstract Introduction We have developed an AI-enabled automated volume measurement of cardiac chambers (AutoChamber) that works on ECG-gated coronary artery calcium scans and correlates well with contrast enhanced coronary CT angiography scans. We have recently reported that increased left atrial volume measured by AutoChamber is a strong predictor of new onset atrial fibrillation (AF) in asymptomatic individuals of Multi-Ethnic Study of Atherosclerosis (MESA). In this study, we compare the volumetry results in ECG- gated CAC scans with those of non-gated full-chest lung cancer screening scans in the same individuals. Methods We have studied 169 cases of paired ECG-gated cardiac CT scans and non-gated lung scans obtained from Harbor UCLA. Mean±SD for age was 62.1±10.0 years with 52% female participants. All cases were asymptomatic and were scanned for preventive health assessment. AutoChamber was run on all cases by an independent operator who was not involved in data analysis. P value was calculated using a two-tailed test of significance with α=0.05. Results AutoChamber in cardiac scans vs lung scans reported volume (Mean±SD) for left atrium (LA) was 63.8 ± 18.5 vs. 65.5 ± 19.4, left ventricle (LV) 102.8 ± 25.3 vs. 105.5 ± 25.2, right atrium (RA) 81.9 ± 20.5 vs. 85.7 ± 21.9 right ventricle (RV), 140.7 ± 34.2 vs. 134.2 ± 33.7, left ventricle wall (LVW) 113.0 ± 26.6 vs. 109.7 ± 27.0 respectively (P < 0.0001). Strong correlation was shown between cardiac and lung scans for each cardiac chamber: LA (R = 0.92), LV (R = 0.93), RA (R = 0.91), RV (R = 0.92), and left ventricular wall (LVW) R = 0.95. Conclusions AutoChamber volumetry results are similar in ECG-gated cardiac scans vs non-gated full-chest lung scans. This AI-enabled automated tool is promising as it can provide added value to patients undergoing coronary calcium and lung cancer screening scans flagging enlarged cardiac chambers at risk of AF and heart failure.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2765
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-enabled automated cardiac chambers volumetry in non-contrast ECG-gated cardiac scans vs. non-contrast non-gated lung scans

Morteza Naghavi, Cornelia Henschke, David F. Yankelevitz, Anthony P. Reeves et al.
1 citations
European Heart Journal
Advanced X-ray and CT Imaging
0.18
article

AI-enabled automated cardiac chambers volumetry in non-contrast ECG-gated cardiac scans vs. non-contrast non-gated lung scans

Morteza Naghavi, Cornelia Henschke, David F. Yankelevitz, Anthony P. Reeves, Matthew Jay Budoff, Kyle Atlas, Chenyu Zhang
article en
1 citations

Abstract

Abstract Introduction We have developed an AI-enabled automated volume measurement of cardiac chambers (AutoChamber) that works on ECG-gated coronary artery calcium scans and correlates well with contrast enhanced coronary CT angiography scans. We have recently reported that increased left atrial volume measured by AutoChamber is a strong predictor of new onset atrial fibrillation (AF) in asymptomatic individuals of Multi-Ethnic Study of Atherosclerosis (MESA). In this study, we compare the volumetry results in ECG- gated CAC scans with those of non-gated full-chest lung cancer screening scans in the same individuals. Methods We have studied 169 cases of paired ECG-gated cardiac CT scans and non-gated lung scans obtained from Harbor UCLA. Mean±SD for age was 62.1±10.0 years with 52% female participants. All cases were asymptomatic and were scanned for preventive health assessment. AutoChamber was run on all cases by an independent operator who was not involved in data analysis. P value was calculated using a two-tailed test of significance with α=0.05. Results AutoChamber in cardiac scans vs lung scans reported volume (Mean±SD) for left atrium (LA) was 63.8 ± 18.5 vs. 65.5 ± 19.4, left ventricle (LV) 102.8 ± 25.3 vs. 105.5 ± 25.2, right atrium (RA) 81.9 ± 20.5 vs. 85.7 ± 21.9 right ventricle (RV), 140.7 ± 34.2 vs. 134.2 ± 33.7, left ventricle wall (LVW) 113.0 ± 26.6 vs. 109.7 ± 27.0 respectively (P < 0.0001). Strong correlation was shown between cardiac and lung scans for each cardiac chamber: LA (R = 0.92), LV (R = 0.93), RA (R = 0.91), RV (R = 0.92), and left ventricular wall (LVW) R = 0.95. Conclusions AutoChamber volumetry results are similar in ECG-gated cardiac scans vs non-gated full-chest lung scans. This AI-enabled automated tool is promising as it can provide added value to patients undergoing coronary calcium and lung cancer screening scans flagging enlarged cardiac chambers at risk of AF and heart failure.

European Heart JournalVol. 45(Supplement_1)
Cornell University (US), Mount Sinai Hospital (US)
Openalex Percentile: Top 51%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.