Evaluating the Effect of Adaptive Reuse in the Energy Performance of Historic Buildings: A Case Study from Türkiye

The building sector accounts for 30% to 40% of total energy consumption, and historic buildings play an important role in this proportion. Historical buildings that do not meet the required comfort conditions for the residents are adaptively reused, with various revisions. Recognizing the energy design of a historical building in its original condition and comparing the current situation can help create future solutions. This study examines the changes that a historic house in a hot climate zone in Türkiye experiences, from its original state up until the current situation. Energy analyses of the pre- and post-restoration situation are carried out, and the effect of adaptive reuse decisions on the energy performance of the building is investigated. A dynamic thermal simulation created with DesignBuilder was used to identify the energy use, carbon emissions, and thermal comfort. TM59 adaptive thermal comfort was used for the pre-restoration and the Fanger model for the post-restoration phase. This building, which was repurposed from a three-block residence, consists of a four-block hotel. Although the preservation of its original value is at the forefront, various structural changes were observed. The analysis demonstrates a higher occurrence of discomfort hours during summer compared to winter, consistent across both phases. Furthermore, energy consumption increased significantly, predominantly for heating, representing a doubling of energy use during the post-restoration phase. This is attributed to the building’s conversion into a hotel and the use of mechanical systems. Future research is required to develop strategies to reduce the energy consumption, carbon emissions, and discomfort hours while maintaining the value of the historic building and its materials.

Authors

Institutions

Publication Details

Journal
Heritage
Published
2024-10-26
DOI
https://doi.org/10.3390/heritage7110285
Citations
2
Primary Topic
Cultural Heritage Management and Preservation
Type
article
Field-Weighted Citation Impact
5.85
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Effect of Adaptive Reuse in the Energy Performance of Historic Buildings: A Case Study from Türkiye

Merve Karabeyeser Bakan, Merve Anaç, Reham Alasmar
2 citations
Heritage
Cultural Heritage Management and Preservation
5.85
article

Evaluating the Effect of Adaptive Reuse in the Energy Performance of Historic Buildings: A Case Study from Türkiye

Merve Karabeyeser Bakan, Merve Anaç, Reham Alasmar
article en
2 citations

Abstract

The building sector accounts for 30% to 40% of total energy consumption, and historic buildings play an important role in this proportion. Historical buildings that do not meet the required comfort conditions for the residents are adaptively reused, with various revisions. Recognizing the energy design of a historical building in its original condition and comparing the current situation can help create future solutions. This study examines the changes that a historic house in a hot climate zone in Türkiye experiences, from its original state up until the current situation. Energy analyses of the pre- and post-restoration situation are carried out, and the effect of adaptive reuse decisions on the energy performance of the building is investigated. A dynamic thermal simulation created with DesignBuilder was used to identify the energy use, carbon emissions, and thermal comfort. TM59 adaptive thermal comfort was used for the pre-restoration and the Fanger model for the post-restoration phase. This building, which was repurposed from a three-block residence, consists of a four-block hotel. Although the preservation of its original value is at the forefront, various structural changes were observed. The analysis demonstrates a higher occurrence of discomfort hours during summer compared to winter, consistent across both phases. Furthermore, energy consumption increased significantly, predominantly for heating, representing a doubling of energy use during the post-restoration phase. This is attributed to the building’s conversion into a hotel and the use of mechanical systems. Future research is required to develop strategies to reduce the energy consumption, carbon emissions, and discomfort hours while maintaining the value of the historic building and its materials.

HeritageVol. 7(11)
English Heritage (GB), Hasan Kalyoncu University (TR), University College London (GB)
Affordable and clean energy
Openalex Percentile: Top 4%
Cultural Heritage Management and Preservation
5.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.