Heart Rate Variability in Dialysis Patients: Changes over the Dialysis Session and Evaluation of a Novel Device

Background: Decreased Heart Rate Variability (HRV) is a measure of poor cardiovascular health and inability of the autonomic nervous system to respond to stress. Accumulation of uremic toxins in kidney failure, volume shifts, and clearance of uremic toxins by dialysis, may impact HRV. We sought to evaluate how HRV changes over the course of hemodialysis with gold-standard electrocardiogram (ECG) and a novel fingertip HRV sensor. Methods: Among 22 participants treated with in-center hemodialysis, we evaluated time-domain and frequency-domain HRV metrics with an ECG (Schiller CARDIOVIT AT-10 Plus) and a novel fingertip sensor (EliteHRV CorSense) at five time points during 2 consecutive dialysis sessions. Changes over the session were evaluated by linear mixed models with random effect terms for participant and session. Devices were compared using correlation coefficients, T-tests, and linear regression. Results: There were no significant changes in HRV metrics over the dialysis session (p-value for trend across ECG 0.11, across CorSense 0.58) (Figure). Time-domain HRV metrics were moderately correlated between the two methods (correlation coefficient for SDNN 0.72 and for RMSSD 0.66), while spectral methods were not (Table). Linear models comparing CorSense and EKG readings suggested strong association for time-domain metrics. Conclusion: On average, HRV metrics did not significantly change over the course of hemodialysis sessions, suggesting that clearance of uremic toxins may not immediately impact cardiovascular health. A novel fingertip sensor accurately measured time-domain (but not frequency-domain) HRV metrics versus a gold-standard EKG device, which may provide a convenient way to assess autonomic neuropathy in dialysis patients. Funding: NIDDK Support - NIDDK Support, NIDDK Support

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2024-10-01
DOI
https://doi.org/10.1681/asn.2024vcnqhkdx
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart Rate Variability in Dialysis Patients: Changes over the Dialysis Session and Evaluation of a Novel Device

Leila R. Zelnick, Ian H. de Boer, Benjamin Lidgard, Nathaniel Ashford et al.
Journal of the American Society of Nephrology
Heart Rate Variability and Autonomic Control
article

Heart Rate Variability in Dialysis Patients: Changes over the Dialysis Session and Evaluation of a Novel Device

Leila R. Zelnick, Ian H. de Boer, Benjamin Lidgard, Nathaniel Ashford, Nisha Bansal
article en

Abstract

Background: Decreased Heart Rate Variability (HRV) is a measure of poor cardiovascular health and inability of the autonomic nervous system to respond to stress. Accumulation of uremic toxins in kidney failure, volume shifts, and clearance of uremic toxins by dialysis, may impact HRV. We sought to evaluate how HRV changes over the course of hemodialysis with gold-standard electrocardiogram (ECG) and a novel fingertip HRV sensor. Methods: Among 22 participants treated with in-center hemodialysis, we evaluated time-domain and frequency-domain HRV metrics with an ECG (Schiller CARDIOVIT AT-10 Plus) and a novel fingertip sensor (EliteHRV CorSense) at five time points during 2 consecutive dialysis sessions. Changes over the session were evaluated by linear mixed models with random effect terms for participant and session. Devices were compared using correlation coefficients, T-tests, and linear regression. Results: There were no significant changes in HRV metrics over the dialysis session (p-value for trend across ECG 0.11, across CorSense 0.58) (Figure). Time-domain HRV metrics were moderately correlated between the two methods (correlation coefficient for SDNN 0.72 and for RMSSD 0.66), while spectral methods were not (Table). Linear models comparing CorSense and EKG readings suggested strong association for time-domain metrics. Conclusion: On average, HRV metrics did not significantly change over the course of hemodialysis sessions, suggesting that clearance of uremic toxins may not immediately impact cardiovascular health. A novel fingertip sensor accurately measured time-domain (but not frequency-domain) HRV metrics versus a gold-standard EKG device, which may provide a convenient way to assess autonomic neuropathy in dialysis patients. Funding: NIDDK Support - NIDDK Support, NIDDK Support

Journal of the American Society of NephrologyVol. 35(10S)
University of Washington (US)
Good health and well-being
Openalex Percentile: Top 65%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.