Hybrid Dialysis Outcomes in Qatar: 3-Year Experience

Background: Hybrid Dialysis is a combined dialysis modality using both Hemodialysis and Peritoneal dialysis. Methods: PD patients with either low solute clearance or inadequate UF despite using the maximum applicable PD regimen were identified. We enrolled twenty-three patients (May 2021-April 2024). All of them were kept on once-weekly HD plus the current PD regimen 6 days per week. We evaluated volume status clinically. Pre-HD urea, potassium, phosphorus, and bicarbonate as indicators of solute clearance, and Albumin level as an indicator of nutritional state. In addition to dialysis catheter-related complications, patient satisfaction and finally checking outcomes. Results: A significant improvement in volume status was associated with a reduction in mean Systolic Blood Pressure (174 ± 32 Vs 135± 15 mmHg, p < 0.0001). All solute clearance indicators showed significant improvement. Reduction in mean urea by 36.7% p-value < 0.001, mean potassium by 23.52% p-value <0.0001, and mean phosphorus reduction of 26.5 % p-value <0.01. The rise in mean bicarbonate was by 15.6 % p-value < 0 .001. Improvement of mean serum albumin p-value <0.05 was observed . Patient satisfaction index was improved. Five patients (21.7%)shifted to Hemodialysis, Five Patients (21.7%), returned to Peritoneal dialysis, three patients (13%) underwent a kidney transplant, two patient leave the country and eight patients (34.8 %) still doing Hybrid dialysis some of them started more than 25 months, average staying was 16 months. Conclusion: Hybrid dialysis is a reasonable dialysis model for patients with frequent volume overload, low solute clearance, or both on PD with significant improvement in volume status, Solute clearance, nutritional status, and patient satisfaction. Hybrid dialysis can be used for more than 24 months. Some patients can return to full PD most of them were started due to volume overload. A larger number of patients and is required to generalize the findings of these observations.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2024-10-01
DOI
https://doi.org/10.1681/asn.2024htqvxtfd
Citations
1
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hybrid Dialysis Outcomes in Qatar: 3-Year Experience

Abdullah Hamad, Liza Chacko, Hanaa H. Ahmed, Mohammed Ezzat Hussain et al.
1 citations
Journal of the American Society of Nephrology
Dialysis and Renal Disease Management
0.34
article

Hybrid Dialysis Outcomes in Qatar: 3-Year Experience

Abdullah Hamad, Liza Chacko, Hanaa H. Ahmed, Mohammed Ezzat Hussain, Mohamad M. Alkadi, Matthew Vergel, Nahid Ibrahim Ali, Ahlam Badawy Ali, Hassan A. Al‐Malki
article en
1 citations

Abstract

Background: Hybrid Dialysis is a combined dialysis modality using both Hemodialysis and Peritoneal dialysis. Methods: PD patients with either low solute clearance or inadequate UF despite using the maximum applicable PD regimen were identified. We enrolled twenty-three patients (May 2021-April 2024). All of them were kept on once-weekly HD plus the current PD regimen 6 days per week. We evaluated volume status clinically. Pre-HD urea, potassium, phosphorus, and bicarbonate as indicators of solute clearance, and Albumin level as an indicator of nutritional state. In addition to dialysis catheter-related complications, patient satisfaction and finally checking outcomes. Results: A significant improvement in volume status was associated with a reduction in mean Systolic Blood Pressure (174 ± 32 Vs 135± 15 mmHg, p < 0.0001). All solute clearance indicators showed significant improvement. Reduction in mean urea by 36.7% p-value < 0.001, mean potassium by 23.52% p-value <0.0001, and mean phosphorus reduction of 26.5 % p-value <0.01. The rise in mean bicarbonate was by 15.6 % p-value < 0 .001. Improvement of mean serum albumin p-value <0.05 was observed . Patient satisfaction index was improved. Five patients (21.7%)shifted to Hemodialysis, Five Patients (21.7%), returned to Peritoneal dialysis, three patients (13%) underwent a kidney transplant, two patient leave the country and eight patients (34.8 %) still doing Hybrid dialysis some of them started more than 25 months, average staying was 16 months. Conclusion: Hybrid dialysis is a reasonable dialysis model for patients with frequent volume overload, low solute clearance, or both on PD with significant improvement in volume status, Solute clearance, nutritional status, and patient satisfaction. Hybrid dialysis can be used for more than 24 months. Some patients can return to full PD most of them were started due to volume overload. A larger number of patients and is required to generalize the findings of these observations.

Journal of the American Society of NephrologyVol. 35(10S)
Hamad Medical Corporation (QA)
Quality Education
Openalex Percentile: Top 34%
Dialysis and Renal Disease Management
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.