Innovation in Dialysis: Air Trap Level Management

Background: Millions with end-stage kidney disease rely on hemodialysis, making the safety of dialysis devices crucial. Air traps in these devices prevent air embolism by removing air bubbles. However, traditional air traps often fail to remove all air, detect microbubbles, or operate autonomously thus increasing the risk for care disruptions and complications. Methods: The Moda-flx Hemodialysis System™ uses a dual mechanism to manage air infusion. The primary system includes an air trap/drip chamber with a level control system. Additionally, a venous air sensor detects air downstream of the air trap. This design ensures introduced air is vented or detected before reaching the patient. Testing scenarios use Dialin to simulate air bubbles in various operational modes. System performance and fault conditions are evaluated at low, moderate, and high rates of continuous air infusion. See Figure 1. Results: At low air infusion rates, the system vents excess air, preventing air from entering the venous line. At moderate rates, if the blood level in the air trap doesn’t recover quickly, the system triggers an alarm, stops the blood pump, and clamps the venous line. At high rates, rapid blood level drops prevent quick venting, allowing air into the venous line. The system triggers an alarm, stops the blood pump, clamps the venous line, and activates dialysate bypass. Comprehensive testing confirms Moda-flx effectively manages air infusion at all rates. Conclusion: The Moda-flx Hemodialysis System™ introduces an innovative approach to air trap management, significantly enhancing patient safety in dialysis treatments. The primary air trap level control system maintains optimal blood levels within the air trap and is complemented by a secondary venous air bubble detection system, ensuring comprehensive risk mitigation. This dual mechanism represents advancements in dialysis device design, ensuring reliable protection in all conditions. Funding: Commercial Support - Diality

Authors

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2024-10-01
DOI
https://doi.org/10.1681/asn.202430jnf1be
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovation in Dialysis: Air Trap Level Management

Enrique Hernández, B Vitas, Susan M. Wall, Osman Khawar et al.
Journal of the American Society of Nephrology
Dialysis and Renal Disease Management
article

Innovation in Dialysis: Air Trap Level Management

Enrique Hernández, B Vitas, Susan M. Wall, Osman Khawar, Nicholas Hyun, Clayton Poppe
article en

Abstract

Background: Millions with end-stage kidney disease rely on hemodialysis, making the safety of dialysis devices crucial. Air traps in these devices prevent air embolism by removing air bubbles. However, traditional air traps often fail to remove all air, detect microbubbles, or operate autonomously thus increasing the risk for care disruptions and complications. Methods: The Moda-flx Hemodialysis System™ uses a dual mechanism to manage air infusion. The primary system includes an air trap/drip chamber with a level control system. Additionally, a venous air sensor detects air downstream of the air trap. This design ensures introduced air is vented or detected before reaching the patient. Testing scenarios use Dialin to simulate air bubbles in various operational modes. System performance and fault conditions are evaluated at low, moderate, and high rates of continuous air infusion. See Figure 1. Results: At low air infusion rates, the system vents excess air, preventing air from entering the venous line. At moderate rates, if the blood level in the air trap doesn’t recover quickly, the system triggers an alarm, stops the blood pump, and clamps the venous line. At high rates, rapid blood level drops prevent quick venting, allowing air into the venous line. The system triggers an alarm, stops the blood pump, clamps the venous line, and activates dialysate bypass. Comprehensive testing confirms Moda-flx effectively manages air infusion at all rates. Conclusion: The Moda-flx Hemodialysis System™ introduces an innovative approach to air trap management, significantly enhancing patient safety in dialysis treatments. The primary air trap level control system maintains optimal blood levels within the air trap and is complemented by a secondary venous air bubble detection system, ensuring comprehensive risk mitigation. This dual mechanism represents advancements in dialysis device design, ensuring reliable protection in all conditions. Funding: Commercial Support - Diality

Journal of the American Society of NephrologyVol. 35(10S)
Industry, innovation and infrastructure
Openalex Percentile: Top 74%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Innovation in Dialysis: Air Trap Level Management — Enrique Hernández, B Vitas, et al. · Journal of the American Society of Nephrology (2024) | TGRS Research Map | TGRS