Intermittent Flow Control Schemes for Heat Stress Mitigation in Lactating Sows on a Floor Cooling Pad

The Purdue hog cooling pad has previously been demonstrated to mitigate heat stress in lactating sows by conductively transferring heat from a sow to cool water running through an integral heat exchanger. Coolant effectiveness, which describes how much heat is removed per volume of water flushed through the cooling pad, is used to compare the operation under varying conditions. Past studies have indicated that the intermittent flow of cooling water achieves a greater coolant effectiveness than continuous flow operational schemes. An electronic control system was implemented with the current cooling pad design to allow for the automated control of a solenoid valve to create the intermittent flow conditions. All testing was performed using 18 ± 1 °C inlet water. Potential control schemes were categorized into two groups, temporal and temperature threshold. The temporal schemes opened the solenoid for 30 s, enough time to flush the entire contents of the cooling coils, before closing for 3, 6, or 9 min. The temperature threshold control schemes utilized feedback from thermal probes embedded beneath the surface of the cooling pad to open the solenoid for 30 s, when a maximum surface temperature was detected. Trigger temperatures of 28.0, 29.5, or 31.0 °C were used. The temperature threshold control schemes achieved greater heat transfer rates (348, 383, 268 W) compared to the temporal control schemes (324, 128, 84 W). The cooling effectiveness for all control schemes ranged from 46.6 to 64.7 kJ/L. The tested intermittent flow control schemes in this study achieved greater cooling effectiveness than continuous flow systems from previous studies (time: 51 kJ/L; temperature: 61 kJ/L; steady: 5.8 kJ/L), although the temporal control schemes exhibited lower heat transfer rates (time: 180 W; temperature: 330 W; steady: 305 W).

Authors

Institutions

Publication Details

Journal
AgriEngineering
Published
2024-10-28
DOI
https://doi.org/10.3390/agriengineering6040226
Primary Topic
Effects of Environmental Stressors on Livestock
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intermittent Flow Control Schemes for Heat Stress Mitigation in Lactating Sows on a Floor Cooling Pad

Allan Paul Schinckel, Tyler C Field, Robert Merton Stwalley III
AgriEngineering
Effects of Environmental Stressors on Livestock
article

Intermittent Flow Control Schemes for Heat Stress Mitigation in Lactating Sows on a Floor Cooling Pad

Allan Paul Schinckel, Tyler C Field, Robert Merton Stwalley III
article en

Abstract

The Purdue hog cooling pad has previously been demonstrated to mitigate heat stress in lactating sows by conductively transferring heat from a sow to cool water running through an integral heat exchanger. Coolant effectiveness, which describes how much heat is removed per volume of water flushed through the cooling pad, is used to compare the operation under varying conditions. Past studies have indicated that the intermittent flow of cooling water achieves a greater coolant effectiveness than continuous flow operational schemes. An electronic control system was implemented with the current cooling pad design to allow for the automated control of a solenoid valve to create the intermittent flow conditions. All testing was performed using 18 ± 1 °C inlet water. Potential control schemes were categorized into two groups, temporal and temperature threshold. The temporal schemes opened the solenoid for 30 s, enough time to flush the entire contents of the cooling coils, before closing for 3, 6, or 9 min. The temperature threshold control schemes utilized feedback from thermal probes embedded beneath the surface of the cooling pad to open the solenoid for 30 s, when a maximum surface temperature was detected. Trigger temperatures of 28.0, 29.5, or 31.0 °C were used. The temperature threshold control schemes achieved greater heat transfer rates (348, 383, 268 W) compared to the temporal control schemes (324, 128, 84 W). The cooling effectiveness for all control schemes ranged from 46.6 to 64.7 kJ/L. The tested intermittent flow control schemes in this study achieved greater cooling effectiveness than continuous flow systems from previous studies (time: 51 kJ/L; temperature: 61 kJ/L; steady: 5.8 kJ/L), although the temporal control schemes exhibited lower heat transfer rates (time: 180 W; temperature: 330 W; steady: 305 W).

AgriEngineeringVol. 6(4)
Purdue University West Lafayette (US), South University (US)
U.S. Department of Agriculture, Purdue University
Clean water and sanitation
Openalex Percentile: Top 79%
Effects of Environmental Stressors on Livestock
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.