Optimizing Permanent Magnet Designs for Improving Control in the Magnetically Controlled Capsule Endoscope

The magnetically controlled capsule endoscopy (MCCE) is a user-friendly device widely used in intestine examinations; however, maintaining its flexible movement through the intestine is still challenging. In this article, three different permanent magnet structures within the MCCE are evaluated. The magnetic forces and torques on the different permanent magnet structures in three dimensions are analyzed through finite element simulations. We experimentally compared the performance of MCCEs with different permanent magnet structures in three aspects: pressure exerted on the intestine under static and dynamic conditions, controllable degrees of freedom and speed of movement. The results showed that the MCCE with a combined permanent magnet structure performed well in shortening the examination time and reducing the pressure on the intestine. These studies provide a reference for the design of permanent magnets.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Magnetics
Published
2024-10-28
DOI
https://doi.org/10.1109/tmag.2024.3486760
Citations
3
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Permanent Magnet Designs for Improving Control in the Magnetically Controlled Capsule Endoscope

Hongbo Sun, Zhifan Teng, Jianhua Liu, Qiuliang Wang et al.
3 citations
IEEE Transactions on Magnetics
Gastrointestinal Bleeding Diagnosis and Treatment
1.39
article

Optimizing Permanent Magnet Designs for Improving Control in the Magnetically Controlled Capsule Endoscope

Hongbo Sun, Zhifan Teng, Jianhua Liu, Qiuliang Wang, Juan Ren
article en
3 citations

Abstract

The magnetically controlled capsule endoscopy (MCCE) is a user-friendly device widely used in intestine examinations; however, maintaining its flexible movement through the intestine is still challenging. In this article, three different permanent magnet structures within the MCCE are evaluated. The magnetic forces and torques on the different permanent magnet structures in three dimensions are analyzed through finite element simulations. We experimentally compared the performance of MCCEs with different permanent magnet structures in three aspects: pressure exerted on the intestine under static and dynamic conditions, controllable degrees of freedom and speed of movement. The results showed that the MCCE with a combined permanent magnet structure performed well in shortening the examination time and reducing the pressure on the intestine. These studies provide a reference for the design of permanent magnets.

IEEE Transactions on MagneticsVol. 60(12)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Institute of Electrical Engineering (CN)
Affordable and clean energy
Openalex Percentile: Top 18%
Gastrointestinal Bleeding Diagnosis and Treatment
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.