Transformer fault identification based on GWO-optimized Dual-channel M-A method

In order to improve the accuracy of the transformer fault identification using nature-inspired algorithms, an identification method based on the GWO (Grey Wolf Optimizer)-optimized Dual-channel MLP (Multilayer Perceptron)-Attention is proposed. First, a Dual-channel model is constructed by combining the AM (Attention Mechanism) and MLP. Subsequently, the GWO algorithm is used to optimize the number and the nodes of the hidden layer in the Dual-channel MLP-Attention model. Typical transformer faults are simulated using DDRTS (Digital Dynamic Real-Time Simulator) system. Experiments showed that the GWO- optimized method has an accuracy rate of 95.3%-96.7% in identifying the transformer faults. Compared with BP, SVM, MLP, and single-channel M-A models, the proposed method improved the accuracy by14.1%, 9.6%, 9.3%, and 3.3% respectively. This result indicates the rationality and effectiveness of the proposed method in transformer fault identification.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-10-28
DOI
https://doi.org/10.1371/journal.pone.0312474
Citations
1
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer fault identification based on GWO-optimized Dual-channel M-A method

Kai Tao, Caina Jiang, Qing Xue, Vincent Ji et al.
1 citations
PLoS ONE
Power Transformer Diagnostics and Insulation
0.21
article

Transformer fault identification based on GWO-optimized Dual-channel M-A method

Kai Tao, Caina Jiang, Qing Xue, Vincent Ji, Wei Wei, Xi Chen, Yifan Bo
article en
1 citations

Abstract

In order to improve the accuracy of the transformer fault identification using nature-inspired algorithms, an identification method based on the GWO (Grey Wolf Optimizer)-optimized Dual-channel MLP (Multilayer Perceptron)-Attention is proposed. First, a Dual-channel model is constructed by combining the AM (Attention Mechanism) and MLP. Subsequently, the GWO algorithm is used to optimize the number and the nodes of the hidden layer in the Dual-channel MLP-Attention model. Typical transformer faults are simulated using DDRTS (Digital Dynamic Real-Time Simulator) system. Experiments showed that the GWO- optimized method has an accuracy rate of 95.3%-96.7% in identifying the transformer faults. Compared with BP, SVM, MLP, and single-channel M-A models, the proposed method improved the accuracy by14.1%, 9.6%, 9.3%, and 3.3% respectively. This result indicates the rationality and effectiveness of the proposed method in transformer fault identification.

PLoS ONEVol. 19(10)
Nanjing University of Posts and Telecommunications (CN), Shanghai Electric (China) (CN)
Science and Technology Project of State Grid, State Grid Jiangsu Electric Power
Openalex Percentile: Top 47%
Power Transformer Diagnostics and Insulation
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.