High Accuracy Measurement of Salinity and Temperature Based on Tilted Grating Concatenated Sagnac Interferometer and ResNet Network

The measurement of salinity and temperature is vital for ocean observation. However, due to the cross-sensitivity phenomenon of fiber sensors, traditional fiber-based demodulation algorithms are difficult to measure the dual-parameter accurately and simultaneously. In this research, a cascaded structure of a tilted fiber Bragg grating (TFBG) and a Sagnac interferometer (SI) is employed to monitor salinity and temperature simultaneously. The transfer learning-based ResNet networks (TFRes) is proposed to demodulate two variables at the same time. A total of 1680 spectral samples were collected for training and testing when the sensor was immersed in sodium chloride solution with different salinities ranging from 0% to 25% with 5% intervals and temperatures ranging from 20 °C to 32 °C with 3 °C intervals. The SI exhibits a temperature sensitivity of −1.458 nm/°C, accompanied by a mean absolute error (MAE) of 0.28 °C. The sensitivity of the TFBG core mode to temperature is 0.009 nm/°C, and the sensitivity of one of the cladding modes to salinity is 0.004 nm/%. After training through the TFRes, we successfully achieved precise demodulation of salinity and temperature variations by analyzing the composite reflection spectra of SI and TFBG. The MAE amounted to 0.07304 °C for temperature and 0.07285% for salinity, outperforming traditional analyzer demodulation methods by a factor of four. The monitoring experiment of dual parameter simultaneous changes is conducted, with a temperature error of 0.18 °C and a salinity error of 0.1%. The designed sensing system is poised to play a significant role in marine physical quantity monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-28
DOI
https://doi.org/10.1109/jsen.2024.3484590
Citations
7
Primary Topic
Water Quality Monitoring Technologies
Type
article
Field-Weighted Citation Impact
1.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High Accuracy Measurement of Salinity and Temperature Based on Tilted Grating Concatenated Sagnac Interferometer and ResNet Network

Yuhui Liu, Renan Xu, Xuming Zhang, Weihao Lin et al.
7 citations
IEEE Sensors Journal
Water Quality Monitoring Technologies
1.41
article

High Accuracy Measurement of Salinity and Temperature Based on Tilted Grating Concatenated Sagnac Interferometer and ResNet Network

Yuhui Liu, Renan Xu, Xuming Zhang, Weihao Lin, Liyang Shao, Perry Ping Shum, Yibin Liu, Xingsheng Yang
article en
7 citations

Abstract

The measurement of salinity and temperature is vital for ocean observation. However, due to the cross-sensitivity phenomenon of fiber sensors, traditional fiber-based demodulation algorithms are difficult to measure the dual-parameter accurately and simultaneously. In this research, a cascaded structure of a tilted fiber Bragg grating (TFBG) and a Sagnac interferometer (SI) is employed to monitor salinity and temperature simultaneously. The transfer learning-based ResNet networks (TFRes) is proposed to demodulate two variables at the same time. A total of 1680 spectral samples were collected for training and testing when the sensor was immersed in sodium chloride solution with different salinities ranging from 0% to 25% with 5% intervals and temperatures ranging from 20 °C to 32 °C with 3 °C intervals. The SI exhibits a temperature sensitivity of −1.458 nm/°C, accompanied by a mean absolute error (MAE) of 0.28 °C. The sensitivity of the TFBG core mode to temperature is 0.009 nm/°C, and the sensitivity of one of the cladding modes to salinity is 0.004 nm/%. After training through the TFRes, we successfully achieved precise demodulation of salinity and temperature variations by analyzing the composite reflection spectra of SI and TFBG. The MAE amounted to 0.07304 °C for temperature and 0.07285% for salinity, outperforming traditional analyzer demodulation methods by a factor of four. The monitoring experiment of dual parameter simultaneous changes is conducted, with a temperature error of 0.18 °C and a salinity error of 0.1%. The designed sensing system is poised to play a significant role in marine physical quantity monitoring.

IEEE Sensors JournalVol. 24(24)
Hong Kong Polytechnic University (HK), Southern University of Science and Technology (CN), Wuhan University (CN), Fujian Institute of Education (CN), Xiamen University of Technology (CN)
Science, Technology and Innovation Commission of Shenzhen Municipality
Openalex Percentile: Top 20%
Water Quality Monitoring Technologies
1.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.