Microwave Radiometer Calibration Using Low-Noise Amplifier as Calibration Source

We present a novel method for built-in noise and gain calibration of a total power radiometer using a low-noise amplifier (LNA) as the calibration source. A terminated LNA’s biasing is varied to obtain multiple calibration points, with the novel postprocessing method accounting for both radiometer nonlinearity and unknown LNA parameters. This method allows for a built-in radiometer calibration without a calibrated resistive or diode noise source, instead using an internal thermometer measurement as a reference. The method is demonstrated by measuring a thermal load to a 24-GHz water vapor radiometer (WVR), achieving a mean error of 0.43 K over the band of interest under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$45~^{\circ } $ </tex-math></inline-formula>C ambient temperature variation. It is further shown that the calibration data can be used to estimate the radiometer’s gain to within 1.41 dB and noise figure (NF) to within 0.55 dB.

Authors

Institutions

Publication Details

Journal
IEEE Microwave and Wireless Technology Letters
Published
2024-10-28
DOI
https://doi.org/10.1109/lmwt.2024.3474971
Primary Topic
Soil Moisture and Remote Sensing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microwave Radiometer Calibration Using Low-Noise Amplifier as Calibration Source

Reuben Neate, Tinus Stander
IEEE Microwave and Wireless Technology Letters
Soil Moisture and Remote Sensing
article

Microwave Radiometer Calibration Using Low-Noise Amplifier as Calibration Source

Reuben Neate, Tinus Stander
article en

Abstract

We present a novel method for built-in noise and gain calibration of a total power radiometer using a low-noise amplifier (LNA) as the calibration source. A terminated LNA’s biasing is varied to obtain multiple calibration points, with the novel postprocessing method accounting for both radiometer nonlinearity and unknown LNA parameters. This method allows for a built-in radiometer calibration without a calibrated resistive or diode noise source, instead using an internal thermometer measurement as a reference. The method is demonstrated by measuring a thermal load to a 24-GHz water vapor radiometer (WVR), achieving a mean error of 0.43 K over the band of interest under <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$45~^{\circ } $ </tex-math></inline-formula>C ambient temperature variation. It is further shown that the calibration data can be used to estimate the radiometer’s gain to within 1.41 dB and noise figure (NF) to within 0.55 dB.

IEEE Microwave and Wireless Technology LettersVol. 35(1)
University of Pretoria (ZA)
Affordable and clean energy
Openalex Percentile: Top 83%
Soil Moisture and Remote Sensing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.