The correlation between cardiac magnetic resonance imaging and echocardiography in patients with severe ischaemic cardiomyopathy

Abstract Background Left ventricular ejection fraction is the single metric that guides therapeutic decision-making, risk stratification and prognosis in patients with severely impaired systolic function. Although cardiac magnetic resonance imaging (CMR) is the current reference standard for quantification of ventricular volume and function, echocardiography is used more often as it is more widely available and less expensive.(1) Aims To evaluate the correlation between CMR and echocardiography in quantifying left ventricular (LV) volume and function and to determine whether these measurements are associated with clinical outcomes in patients with severe ischemic cardiomyopathy (ICM). Methods Participants recruited to the REVIVED-BCIS2 trial who had undergone baseline CMR or echocardiography were included in this analysis. All scans were analyzed in blinded core laboratories as previously reported.(2,3) All volumes were indexed to body surface area. Spearman correlation, Bland Altman analysis and coverage probability methods were performed to assess the correlation between the two modalities. A Cox proportional hazards model was used to assess the association between imaging metrics and the primary outcome, a composite of all-cause death and aborted sudden death. A sensitivity analysis was conducted a priori, restricted to patients undergoing both scans within 60 days of each other. Results A total of 373 participants with paired imaging data were included: mean age 69±9 years, 87% male, BMI 28±5. A moderate correlation was detected for volume measurements between the modalities (end diastolic volume index (EDVI) r=0.66 end systolic volume index (ESVI) r=0.68), with a weaker correlation for LV ejection fraction (EF) (r=0.41). Bland-Altman plots showed moderate agreement in LVEF measurements (Table 1). The sensitivity analysis included 199 patients, and showed similar results (EDVI r=0.72, ESVI r=0.73 LVEF r=0.43, all p<0.000). Only 7.5% of the paired LVEF measurements were within 5% of each other. 30% of participants were misclassified by echocardiography as having an LVEF>35%. (Figure 1) CMR ESVI was associated with the occurrence of the primary outcome (HR 1.05 per 10ml increment, 95% CI 1.00-1.10) however echo ESVI (HR 1.05 per 10ml increment 95% CI 0.99 – 1.10) and all other imaging metrics were not. Conclusion Left ventricular volumes and ejection fraction on CMR and echocardiography were only modestly correlated in this population with severe ICM. When using the binary EF threshold of 35% that is commonly used to select patients of implantable defibrillator therapy, almost a third of patients at risk would have been missed by echocardiography alone. The additional insights provided by CMR, including scar burden, further support preferential use of this modality in the assessment such patients.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.307
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The correlation between cardiac magnetic resonance imaging and echocardiography in patients with severe ischaemic cardiomyopathy

Holly Morgan, Stamatis Kapetanakis, Amedeo Chiribiri, Divaka Perera et al.
European Heart Journal
Cardiac Imaging and Diagnostics
article

The correlation between cardiac magnetic resonance imaging and echocardiography in patients with severe ischaemic cardiomyopathy

Holly Morgan, Stamatis Kapetanakis, Amedeo Chiribiri, Divaka Perera, Jenny Draper, Roxy Senior, M. J. Ryan, Ebraham Alskaf, Alexandros Papachristidis, Jennifer Mâncio, Tesfamariam Betemariam
article en

Abstract

Abstract Background Left ventricular ejection fraction is the single metric that guides therapeutic decision-making, risk stratification and prognosis in patients with severely impaired systolic function. Although cardiac magnetic resonance imaging (CMR) is the current reference standard for quantification of ventricular volume and function, echocardiography is used more often as it is more widely available and less expensive.(1) Aims To evaluate the correlation between CMR and echocardiography in quantifying left ventricular (LV) volume and function and to determine whether these measurements are associated with clinical outcomes in patients with severe ischemic cardiomyopathy (ICM). Methods Participants recruited to the REVIVED-BCIS2 trial who had undergone baseline CMR or echocardiography were included in this analysis. All scans were analyzed in blinded core laboratories as previously reported.(2,3) All volumes were indexed to body surface area. Spearman correlation, Bland Altman analysis and coverage probability methods were performed to assess the correlation between the two modalities. A Cox proportional hazards model was used to assess the association between imaging metrics and the primary outcome, a composite of all-cause death and aborted sudden death. A sensitivity analysis was conducted a priori, restricted to patients undergoing both scans within 60 days of each other. Results A total of 373 participants with paired imaging data were included: mean age 69±9 years, 87% male, BMI 28±5. A moderate correlation was detected for volume measurements between the modalities (end diastolic volume index (EDVI) r=0.66 end systolic volume index (ESVI) r=0.68), with a weaker correlation for LV ejection fraction (EF) (r=0.41). Bland-Altman plots showed moderate agreement in LVEF measurements (Table 1). The sensitivity analysis included 199 patients, and showed similar results (EDVI r=0.72, ESVI r=0.73 LVEF r=0.43, all p<0.000). Only 7.5% of the paired LVEF measurements were within 5% of each other. 30% of participants were misclassified by echocardiography as having an LVEF>35%. (Figure 1) CMR ESVI was associated with the occurrence of the primary outcome (HR 1.05 per 10ml increment, 95% CI 1.00-1.10) however echo ESVI (HR 1.05 per 10ml increment 95% CI 0.99 – 1.10) and all other imaging metrics were not. Conclusion Left ventricular volumes and ejection fraction on CMR and echocardiography were only modestly correlated in this population with severe ICM. When using the binary EF threshold of 35% that is commonly used to select patients of implantable defibrillator therapy, almost a third of patients at risk would have been missed by echocardiography alone. The additional insights provided by CMR, including scar burden, further support preferential use of this modality in the assessment such patients.

European Heart JournalVol. 45(Supplement_1)
King's College London (GB), Harefield Hospital (GB), St. Thomas Hospital (CA), Addis Ababa University (ET)
Openalex Percentile: Top 68%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.