Blood pressure and renal function responses in workers exposed to lead for up to six years

Abstract Background Lead is a widespread environmental toxicant. However, there is currently no consensus whether low-level lead exposure raises blood pressure (BP) or induces kidney dysfunction. Purpose The Study for Promotion of Health in Recycling Lead (SPHERL) assessed the BP and renal function (RF) responses for up to six years in the workers without previous occupational lead exposure. Methods BP was the average of 5 consecutive readings and the estimated glomerular filtration rate was derived from serum creatinine (eGFRcrt) and cystatin C (eGFRcys). Blood lead (BL) was measured by inductively coupled plasma mass spectrometry (detection limit 0.5 mg/dL). The statistical methods included multivariable-adjusted mixed models and interval-censored Cox regression analysis. Results The 234 workers analyzed were on average 28.5 years old and included 91.9% men. The baseline BL concentration was 4.35 µg/dL and increased 3.17-fold over follow-up (median: 2.03 years; range: 0.92-6.45 years). The changes in BP and RF were not significantly correlated with the follow-up-to-baseline BL ratio (p≥0.51 and p≥0.18, respectively). The fully-adjusted changes in systolic/diastolic BP associated with a doubling of BL were -0.25/-0.12 mm Hg (CI: -0.94 to 0.44/-0.66 to 0.42 mm Hg). Accordingly, the incidence of stage-1 or -2 hypertension was not associated with the BL change (p≥0.063). Similarly, the changes in eGFRcrt and eGFRcys associated with a 3-fold BL increment were not significant, amounting to -0.70 mL/min/1.73 m2(CI: -1.70 to 0.30 mL/min/1.73 m2) and -1.06 ml/min/1.73 m2 (-2.16 to 0.03 mL/min/1.73 m2). Conclusion The BP and RF responses to an over 3-fold BL increment were small and not significant confirming the safety of modern lead-handing facilities operating under current safety rules.Figure 1Figure 2

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2948
Primary Topic
Heavy Metal Exposure and Toxicity
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blood pressure and renal function responses in workers exposed to lead for up to six years

Y Yu, De‐Wei An, Jan A. Staessen, Peter Verhamme et al.
European Heart Journal
Heavy Metal Exposure and Toxicity
article

Blood pressure and renal function responses in workers exposed to lead for up to six years

Y Yu, De‐Wei An, Jan A. Staessen, Peter Verhamme, Tim S. Nawrot, Wen‐Yi Yang, A Allegaert
article en

Abstract

Abstract Background Lead is a widespread environmental toxicant. However, there is currently no consensus whether low-level lead exposure raises blood pressure (BP) or induces kidney dysfunction. Purpose The Study for Promotion of Health in Recycling Lead (SPHERL) assessed the BP and renal function (RF) responses for up to six years in the workers without previous occupational lead exposure. Methods BP was the average of 5 consecutive readings and the estimated glomerular filtration rate was derived from serum creatinine (eGFRcrt) and cystatin C (eGFRcys). Blood lead (BL) was measured by inductively coupled plasma mass spectrometry (detection limit 0.5 mg/dL). The statistical methods included multivariable-adjusted mixed models and interval-censored Cox regression analysis. Results The 234 workers analyzed were on average 28.5 years old and included 91.9% men. The baseline BL concentration was 4.35 µg/dL and increased 3.17-fold over follow-up (median: 2.03 years; range: 0.92-6.45 years). The changes in BP and RF were not significantly correlated with the follow-up-to-baseline BL ratio (p≥0.51 and p≥0.18, respectively). The fully-adjusted changes in systolic/diastolic BP associated with a doubling of BL were -0.25/-0.12 mm Hg (CI: -0.94 to 0.44/-0.66 to 0.42 mm Hg). Accordingly, the incidence of stage-1 or -2 hypertension was not associated with the BL change (p≥0.063). Similarly, the changes in eGFRcrt and eGFRcys associated with a 3-fold BL increment were not significant, amounting to -0.70 mL/min/1.73 m2(CI: -1.70 to 0.30 mL/min/1.73 m2) and -1.06 ml/min/1.73 m2 (-2.16 to 0.03 mL/min/1.73 m2). Conclusion The BP and RF responses to an over 3-fold BL increment were small and not significant confirming the safety of modern lead-handing facilities operating under current safety rules.Figure 1Figure 2

European Heart JournalVol. 45(Supplement_1)
Shanghai First People's Hospital (CN), KU Leuven (BE)
Omron Healthcare
Openalex Percentile: Top 74%
Heavy Metal Exposure and Toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.