Interethnic validation of an artificial intelligence algorithm for prediction of atrial fibrillation using sinus rhythm electrocardiogram

Abstract Background Previous research has demonstrated acceptable diagnostic accuracy of artificial intelligence (AI)-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation for identifying paroxysmal atrial fibrillation (AF). However, interethnic validations of the AI algorithms have not been widely conducted. Purpose We aimed to develop our own AI model for the identification of paroxysmal AF based on SR ECGs in the Korean population and to validate its diagnostic performance in Brazilian citizens. Methods We trained a Transformer-based vision network on 90% of a dataset comprising 808,194 ECGs from 121,282 patients at Seoul National University Bundang Hospital (2003-2020). The remaining 10% of the dataset was used for internal validation. The model was trained to compute a risk score for paroxysmal AF or new-onset AF within 2 years. External validation was conducted using non-AF ECGs from the CODE 15% dataset provided by the Telehealth Network of Minas Gerais, Brazil. Results In internal validation, our AI model achieved an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.911 (95% CI: 0.902 - 0.921), with a sensitivity of 78.1% and a specificity of 89.0%. Subgroup analyses showed an AUROC of 0.893 (95% CI: 0.876 - 0.909) for patients in routine health checkups or outpatient settings, and 0.854 for patients with "Normal ECG" interpretations. In external validation with the CODE 15% dataset, the AI model exhibited an AUROC of 0.884 (95% CI: 0.869-0.900), which increased to 0.906 (95% CI: 0.893-0.919) when adjusted for age and sex (Figure 1). In the subset of patients with "Normal ECG" interpretations, the AUROC was 0.826 (95% CI: 0.769-0.883), increasing to 0.861 (95% CI: 0.814-0.908) after applying the same adjustments. Conclusions Our AI-powered SR ECG interpretation model demonstrated excellent diagnostic performance in predicting paroxysmal AF, with valid performance in the Brazilian population as well. This suggests that the model has potential for broad application across different ethnic groups.Figure 1

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.3432
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interethnic validation of an artificial intelligence algorithm for prediction of atrial fibrillation using sinus rhythm electrocardiogram

Jae‐Weon Kim, Il‐Young Oh, Jung‐Yeon Choi, J H Lee et al.
European Heart Journal
ECG Monitoring and Analysis
article

Interethnic validation of an artificial intelligence algorithm for prediction of atrial fibrillation using sinus rhythm electrocardiogram

Jae‐Weon Kim, Il‐Young Oh, Jung‐Yeon Choi, J H Lee, Y Cho
article en

Abstract

Abstract Background Previous research has demonstrated acceptable diagnostic accuracy of artificial intelligence (AI)-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation for identifying paroxysmal atrial fibrillation (AF). However, interethnic validations of the AI algorithms have not been widely conducted. Purpose We aimed to develop our own AI model for the identification of paroxysmal AF based on SR ECGs in the Korean population and to validate its diagnostic performance in Brazilian citizens. Methods We trained a Transformer-based vision network on 90% of a dataset comprising 808,194 ECGs from 121,282 patients at Seoul National University Bundang Hospital (2003-2020). The remaining 10% of the dataset was used for internal validation. The model was trained to compute a risk score for paroxysmal AF or new-onset AF within 2 years. External validation was conducted using non-AF ECGs from the CODE 15% dataset provided by the Telehealth Network of Minas Gerais, Brazil. Results In internal validation, our AI model achieved an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.911 (95% CI: 0.902 - 0.921), with a sensitivity of 78.1% and a specificity of 89.0%. Subgroup analyses showed an AUROC of 0.893 (95% CI: 0.876 - 0.909) for patients in routine health checkups or outpatient settings, and 0.854 for patients with "Normal ECG" interpretations. In external validation with the CODE 15% dataset, the AI model exhibited an AUROC of 0.884 (95% CI: 0.869-0.900), which increased to 0.906 (95% CI: 0.893-0.919) when adjusted for age and sex (Figure 1). In the subset of patients with "Normal ECG" interpretations, the AUROC was 0.826 (95% CI: 0.769-0.883), increasing to 0.861 (95% CI: 0.814-0.908) after applying the same adjustments. Conclusions Our AI-powered SR ECG interpretation model demonstrated excellent diagnostic performance in predicting paroxysmal AF, with valid performance in the Brazilian population as well. This suggests that the model has potential for broad application across different ethnic groups.Figure 1

European Heart JournalVol. 45(Supplement_1)
Seoul National University Bundang Hospital (KR)
Openalex Percentile: Top 65%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.