No reimbursement policy and implantable loop recorders in the real world setting

Abstract Background Prolonged heart rhythm evaluation is indicated in patients with suspected arrhythmias. Routine electrocardiographic Holter monitoring is often associated with poor adherence and may lead to little to no clinically relevant findings. Implantable loop recorders (ILRs) are small, subcutaneous cardiac devices providing semi-continuous electrocardiographic recording. Despite strong evidence supporting their effectiveness, ILRs are yet to be fully reimbursed by the National Health Fund- the public insurer in Poland. Purpose We aimed to investigate the feasibility, as well as the diagnostic yield of ILRs in a real world setting of a tertiary cardiovascular center. Methods We retrospectively analyzed data of consecutive patients admitted for ILR implantation between March 2013 nad November 2023. Hospitalization and procedural costs were covered by the clinic's statutory and hospital funds and not by the National Health Fund, the public payer. All patients were remotely monitored for device follow-up. Baseline demographic characteristics, as well as data regarding observation period, clinical outcomes and safety were collected. Results Data for 51 ILR implants in 50 patients was assessed. Insertion success rate was 100% on first attempt with no complications. Mean age was 54,43 ±18,56 years old. 52,94% of patients were female. Coronary artery disease was present in 21,57% patients, hypertension in 50,98%, diabetes in 13,73%. The indications for ILR implantation were unexplained syncope (n= 42; 82,35%), palpitations (n= 16; 31,37%), ischemic stroke of unknown origin (n= 6; 11,76%), monitoring of ventricular arrhythmia (n= 2; 3,92%). Mean time between occurrence of first symptoms and ILR implantation was 80,86 ±112,95 months. Mean monitoring period was 1067,62 ±668,89 days. 23 (45,1%) patients had an actionable event detected. Mean time to clinical outcome was 190,34 ±514,85 days. Based on the obtained recordings, in 13 (25,49%) patients a cardiac electronic device was implanted and 6 (11,76%) underwent an electrophysiological procedure. Time to intervention was 435,17 ± 542,9 days and 338,8 ± 273,44 days, respectively. ILR prompted medication modification in 14 (27,45%) patients. Antiarrhythmic drugs were modified in 6 (11,76%) patients. Oral anticoagulation was initiated in 3 (5,88%) patients. Mean time to any pharmacotherapy modification was 654,68 ± 604,32 days. Skin infections occurred in 2 patients, leading to early device removal. Conclusions This is the first study to present a comprehensive evaluation of ILR patients in Poland, along with a substantial observation period. We report a high prevalence of treatable cardiac conditions in patients with previous unsuccessful diagnostic work up. In the light of the upcoming favourable changes in governmental healthcare policy, demonstrating evidence supporting ILR application in everyday clinical practice is crucial for advocating their wider utilization and reimbursement.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.341
Primary Topic
Library Science and Information Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

No reimbursement policy and implantable loop recorders in the real world setting

Marcin Grabowski, Maria Boszko, Marcin Michalak, P P Patryk Pindlowski et al.
European Heart Journal
Library Science and Information Systems
article

No reimbursement policy and implantable loop recorders in the real world setting

Marcin Grabowski, Maria Boszko, Marcin Michalak, P P Patryk Pindlowski, J K R Jakub Kosma Rokici
article en

Abstract

Abstract Background Prolonged heart rhythm evaluation is indicated in patients with suspected arrhythmias. Routine electrocardiographic Holter monitoring is often associated with poor adherence and may lead to little to no clinically relevant findings. Implantable loop recorders (ILRs) are small, subcutaneous cardiac devices providing semi-continuous electrocardiographic recording. Despite strong evidence supporting their effectiveness, ILRs are yet to be fully reimbursed by the National Health Fund- the public insurer in Poland. Purpose We aimed to investigate the feasibility, as well as the diagnostic yield of ILRs in a real world setting of a tertiary cardiovascular center. Methods We retrospectively analyzed data of consecutive patients admitted for ILR implantation between March 2013 nad November 2023. Hospitalization and procedural costs were covered by the clinic's statutory and hospital funds and not by the National Health Fund, the public payer. All patients were remotely monitored for device follow-up. Baseline demographic characteristics, as well as data regarding observation period, clinical outcomes and safety were collected. Results Data for 51 ILR implants in 50 patients was assessed. Insertion success rate was 100% on first attempt with no complications. Mean age was 54,43 ±18,56 years old. 52,94% of patients were female. Coronary artery disease was present in 21,57% patients, hypertension in 50,98%, diabetes in 13,73%. The indications for ILR implantation were unexplained syncope (n= 42; 82,35%), palpitations (n= 16; 31,37%), ischemic stroke of unknown origin (n= 6; 11,76%), monitoring of ventricular arrhythmia (n= 2; 3,92%). Mean time between occurrence of first symptoms and ILR implantation was 80,86 ±112,95 months. Mean monitoring period was 1067,62 ±668,89 days. 23 (45,1%) patients had an actionable event detected. Mean time to clinical outcome was 190,34 ±514,85 days. Based on the obtained recordings, in 13 (25,49%) patients a cardiac electronic device was implanted and 6 (11,76%) underwent an electrophysiological procedure. Time to intervention was 435,17 ± 542,9 days and 338,8 ± 273,44 days, respectively. ILR prompted medication modification in 14 (27,45%) patients. Antiarrhythmic drugs were modified in 6 (11,76%) patients. Oral anticoagulation was initiated in 3 (5,88%) patients. Mean time to any pharmacotherapy modification was 654,68 ± 604,32 days. Skin infections occurred in 2 patients, leading to early device removal. Conclusions This is the first study to present a comprehensive evaluation of ILR patients in Poland, along with a substantial observation period. We report a high prevalence of treatable cardiac conditions in patients with previous unsuccessful diagnostic work up. In the light of the upcoming favourable changes in governmental healthcare policy, demonstrating evidence supporting ILR application in everyday clinical practice is crucial for advocating their wider utilization and reimbursement.

European Heart JournalVol. 45(Supplement_1)
Medical University of Warsaw (PL)
No poverty
Openalex Percentile: Top 71%
Library Science and Information Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.