Enhancing Surgical Care: Development of Biocompatible, Superabsorbent Alternatives to Cotton Gauze Using Chia Mucilage and Poly(vinylpyrrolidone)

Cotton gauze bandages have traditionally played a pivotal role in wound care and surgical procedures, absorbing fluids, including blood, and protecting against infection. However, their limited liquid absorption capacity raises concern about potential post-surgery complications if inadvertently retained. In response, resorbable and biocompatible polymers have emerged as a promising alternative to enhance surgical outcomes and mitigate inflammation. This study aims to develop a biocompatible, highly absorbent, and preferably resorbable substitute for cotton gauze, utilizing natural polysaccharides from chia seeds' mucilage alongside the synthetic polymer poly(vinylpyrrolidone) (PVP). Incorporating tranexamic acid, an antifibrinolytic agent, into the PVP solution enhances its efficacy in controlling blood flow. The polymer solution is then processed into nonwoven materials via solution blow spinning. UV-C radiation cross-linking is employed to bolster the nonwovens' performance and durability during liquid absorption and swelling. Results demonstrate that nonwoven samples comprising PVP and chia mucilage, cross-linked for 60 min with UV-C radiation, exhibit exceptional swelling capacity, absorbing approximately 3291% of their dry weight in saline solution. Microfiber analysis indicates alterations in fiber characteristics due to cross-linking duration. Cell viability tests affirm the biocompatibility of the produced materials. With their remarkable fluid absorption properties and potential for resorption, PVP/chia mucilage compositions supplemented with tranexamic acid offer a promising avenue for effectively managing surgical bleeding without adverse effects. Furthermore, these materials can safely remain within the surgical site, eventually undergoing natural resorption by the body owing to their resorbable nature.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2024-10-28
DOI
https://doi.org/10.1021/acsomega.4c08073
Citations
3
Primary Topic
Hemostasis and retained surgical items
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Surgical Care: Development of Biocompatible, Superabsorbent Alternatives to Cotton Gauze Using Chia Mucilage and Poly(vinylpyrrolidone)

Andréa Cristiane Krause Bierhalz, Ana Paula Serafini Immich, Antônio Augusto Ulson de Souza, Paulo Emílio Feuser et al.
3 citations
ACS Omega
Hemostasis and retained surgical items
1.36
article

Enhancing Surgical Care: Development of Biocompatible, Superabsorbent Alternatives to Cotton Gauze Using Chia Mucilage and Poly(vinylpyrrolidone)

Andréa Cristiane Krause Bierhalz, Ana Paula Serafini Immich, Antônio Augusto Ulson de Souza, Paulo Emílio Feuser, Kainan Akio Weege
article en
3 citations

Abstract

Cotton gauze bandages have traditionally played a pivotal role in wound care and surgical procedures, absorbing fluids, including blood, and protecting against infection. However, their limited liquid absorption capacity raises concern about potential post-surgery complications if inadvertently retained. In response, resorbable and biocompatible polymers have emerged as a promising alternative to enhance surgical outcomes and mitigate inflammation. This study aims to develop a biocompatible, highly absorbent, and preferably resorbable substitute for cotton gauze, utilizing natural polysaccharides from chia seeds' mucilage alongside the synthetic polymer poly(vinylpyrrolidone) (PVP). Incorporating tranexamic acid, an antifibrinolytic agent, into the PVP solution enhances its efficacy in controlling blood flow. The polymer solution is then processed into nonwoven materials via solution blow spinning. UV-C radiation cross-linking is employed to bolster the nonwovens' performance and durability during liquid absorption and swelling. Results demonstrate that nonwoven samples comprising PVP and chia mucilage, cross-linked for 60 min with UV-C radiation, exhibit exceptional swelling capacity, absorbing approximately 3291% of their dry weight in saline solution. Microfiber analysis indicates alterations in fiber characteristics due to cross-linking duration. Cell viability tests affirm the biocompatibility of the produced materials. With their remarkable fluid absorption properties and potential for resorption, PVP/chia mucilage compositions supplemented with tranexamic acid offer a promising avenue for effectively managing surgical bleeding without adverse effects. Furthermore, these materials can safely remain within the surgical site, eventually undergoing natural resorption by the body owing to their resorbable nature.

ACS OmegaVol. 9(45)
Universidade Federal de Santa Catarina (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zero hunger
Openalex Percentile: Top 17%
Hemostasis and retained surgical items
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.