Initial results of the Hyperion II<sup>D</sup> PET insert for simultaneous PET-MRI applied to atherosclerotic plaque imaging in New-Zealand white rabbits
<i>Objective.</i>In preclinical research,<i>in vivo</i>imaging of mice and rats is more common than any other animal species, since their physiopathology is very well-known and many genetically altered disease models exist. Animal studies based on small rodents are usually performed using dedicated preclinical imaging systems with high spatial resolution. For studies that require animal models such as mini-pigs or New-Zealand White (NZW) rabbits, imaging systems with larger bore sizes are required. In case of hybrid imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI), clinical systems have to be used, as these animal models do not typically fit in preclinical simultaneous PET-MRI scanners.<i>Approach.</i>In this paper, we present initial imaging results obtained with the Hyperion II<sup>D</sup>PET insert which can accommodate NZW rabbits when combined with a large volume MRI RF coil. First, we developed a rabbit-sized image quality phantom of comparable size to a NZW rabbit in order to evaluate the PET imaging performance of the insert under high count rates. For this phantom, radioactive spheres with inner diameters between 3.95 and7.86mm were visible in a warm background with a tracer activity ratio of 4.1 to 1 and with a total<sup>18</sup>F activity in the phantom of58MBq at measurement start. Second, we performed simultaneous PET-MR imaging of atherosclerotic plaques in a rabbit<i>in vivo</i>using a single injection containing<sup>18</sup>F-FDG for detection of inflammatory activity, and Gd-ESMA for visualization of the aortic vessel wall and plaques with MRI.<i>Main results.</i>The fused PET-MR images reveal<sup>18</sup>F-FDG uptake within an active plaques with plaque thicknesses in the sub-millimeter range. Histology showed colocalization of<sup>18</sup>F-FDG uptake with macrophages in the aortic vessel wall lesions.<i>Significance.</i>Our initial results demonstrate that this PET insert is a promising system for simultaneous high-resolution PET-MR atherosclerotic plaque imaging studies in NZW rabbits.
Authors
- Markus Henningsson (ORCID: https://orcid.org/0000-0001-6142-3005)
- René M. Botnar (ORCID: https://orcid.org/0000-0003-2811-2509)
- Begoña Lavín (ORCID: https://orcid.org/0000-0003-4671-1089)
- Paul Marsden (ORCID: https://orcid.org/0000-0001-9892-9640)
- Pierre Gebhardt (ORCID: https://orcid.org/0000-0001-9858-7425)
- Volkmar Schulz (ORCID: https://orcid.org/0000-0003-1341-9356)
- David Schug (ORCID: https://orcid.org/0000-0002-5154-8303)
- Alkystis Phinikaridou
- André Salomon
- Jane E. Mackewn
Institutions
- Linköping University (SE)
- NXP (Netherlands) (NL)
- Universidad Complutense de Madrid (ES)
- St Thomas' Hospital (GB)
- Philips (Finland) (FI)
- Pontificia Universidad Católica de Chile (CL)
- King's College London (GB)
- Bruker (United States) (US)
- Lambeth Hospital (GB)
- Fraunhofer Institute for Production Technology IPT (DE)
- Philips (Netherlands) (NL)
- Fraunhofer Institute for Digital Medicine (DE)
- Eindhoven University of Technology (NL)
- RWTH Aachen University (DE)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2024-10-28
- DOI
- https://doi.org/10.1088/1361-6560/ad8c1f
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Wellcome Trust
- Medical Engineering Centre, King’s College London
- Engineering and Physical Sciences Research Council