Image quality of the non-contrast BOOST cardiac magnetic resonance sequence to visualize the pulmonary veins in patients with atrial fibrillation

Abstract Background In patients with atrial fibrillation (AF), imaging examinations have an important role in planning ablation by imaging the pulmonary veins (PV). The PV anatomy is conventionally assessed before ablation using computer tomography (CT) or 3 dimensional (3D) contrast-enhanced cardiac magnetic resonance (CMR) imaging. The new 3-dimensional, free-breathing BOOST (Bright-blood and black-blOOd phase SensiTive inversion recovery) cardiac magnetic resonance (CMR) sequence is suitable for imaging the left atrium without the addition of contrast agent. Purpose The aim of our study was to investigate the BOOST sequence for the imaging of PVs, and the effect of heart rate and rhythm on image quality. Methods Forty-seven patients underwent and BOOST CMR before ablation, 25 of them had also left atrial CT angiography (CTA). The BOOST sequence was performed using T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) techniques. The image quality was analyzed using a subjective Likert scale and quantitatively by determining the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Heart rate and rhythm were assessed by 12-lead ECG. Results MTC-BOOST images were suitable for PVs analysis in all cases, whereas the assessment of PVs on T2prep-BOOST images was inadequate in the majority of cases due to artifacts. CTA showed the same PV anatomy as assessed with BOOST CMR. Based on the operating electrophysiologists’ subjective opinion, the quality of the CTA scans was better compared with BOOST sequence. Still, they found the CMR images appropriate for procedural planning in 43 out of 47 cases (91%). SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. Conclusions MTC-BOOST images are suitable for visualisation of PVs, producing diagnostic image quality in 100% of cases. In the majority of cases, MTC-BOOST images were appropriate for procedural planning before ablation. Image quality is affected by the patients' heart rate and frequency. Figure 1: MTC BOOST bright blood image of the left atrium and the right pulmonary veins (arrows)

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.241
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image quality of the non-contrast BOOST cardiac magnetic resonance sequence to visualize the pulmonary veins in patients with atrial fibrillation

G Orban, Karl Kunze, Claudia Prieto, Hajnalka Vágó et al.
European Heart Journal
Advanced MRI Techniques and Applications
article

Image quality of the non-contrast BOOST cardiac magnetic resonance sequence to visualize the pulmonary veins in patients with atrial fibrillation

G Orban, Karl Kunze, Claudia Prieto, Hajnalka Vágó, Máté G. Kiss, René M. Botnar, L Szabó, F Suhai, Nándor Szegedi, Zsófia Dohy, Z Drobni, Radhouène Neji, László Gellér, C Czimbalmos, B Merkely
article en

Abstract

Abstract Background In patients with atrial fibrillation (AF), imaging examinations have an important role in planning ablation by imaging the pulmonary veins (PV). The PV anatomy is conventionally assessed before ablation using computer tomography (CT) or 3 dimensional (3D) contrast-enhanced cardiac magnetic resonance (CMR) imaging. The new 3-dimensional, free-breathing BOOST (Bright-blood and black-blOOd phase SensiTive inversion recovery) cardiac magnetic resonance (CMR) sequence is suitable for imaging the left atrium without the addition of contrast agent. Purpose The aim of our study was to investigate the BOOST sequence for the imaging of PVs, and the effect of heart rate and rhythm on image quality. Methods Forty-seven patients underwent and BOOST CMR before ablation, 25 of them had also left atrial CT angiography (CTA). The BOOST sequence was performed using T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) techniques. The image quality was analyzed using a subjective Likert scale and quantitatively by determining the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Heart rate and rhythm were assessed by 12-lead ECG. Results MTC-BOOST images were suitable for PVs analysis in all cases, whereas the assessment of PVs on T2prep-BOOST images was inadequate in the majority of cases due to artifacts. CTA showed the same PV anatomy as assessed with BOOST CMR. Based on the operating electrophysiologists’ subjective opinion, the quality of the CTA scans was better compared with BOOST sequence. Still, they found the CMR images appropriate for procedural planning in 43 out of 47 cases (91%). SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. Conclusions MTC-BOOST images are suitable for visualisation of PVs, producing diagnostic image quality in 100% of cases. In the majority of cases, MTC-BOOST images were appropriate for procedural planning before ablation. Image quality is affected by the patients' heart rate and frequency. Figure 1: MTC BOOST bright blood image of the left atrium and the right pulmonary veins (arrows)

European Heart JournalVol. 45(Supplement_1)
Semmelweis University (HU), Siemens (Hungary) (HU), King's College London (GB), Siemens Healthineers (Germany) (DE)
European Commission
Openalex Percentile: Top 68%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.