Sensitivity of wavelet-based optical flow velocimetry (wOFV) to common experimental error sources

Abstract The influence of several potential error sources and non-ideal experimental effects on the accuracy of a wavelet-based optical flow velocimetry (wOFV) method when applied to tracer particle images is evaluated using data from a series of synthetic flows. Out-of-plane particle displacements, severe image noise, laser sheet thickness reduction, and image intensity non-uniformity are shown to decrease the accuracy of wOFV in a similar manner to correlation-based particle image velocimetry (PIV). For the error sources tested, wOFV displays a similar or slightly increased sensitivity compared to PIV, but the wOFV results are still more accurate than PIV when the magnitude of the non-ideal effects remain within expected experimental bounds. For the majority of test cases, the results are significantly improved by using image pre-processing filters and the magnitude of improvement is consistent between wOFV and PIV. Flow divergence does not appear to have an appreciable effect on the accuracy of wOFV velocity estimation, even though the underlying fluid transport equation on which wOFV is based implicitly assumes that the motion is divergence-free. This is a significant finding for the broader applicability of planar velocimetry measurements using wOFV. Finally, it is noted that the accuracy of wOFV is not reduced notably in regions of the image between tracer particles, as long as the overall seeding density is not too sparse i.e. below 0.02 particles per pixel. This explicitly demonstrates that wOFV (when applied to particle images) yields an accurate whole field measurement, and not only at or adjacent to the discrete particle locations.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2024-10-28
DOI
https://doi.org/10.1088/1361-6501/ad8be8
Citations
5
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitivity of wavelet-based optical flow velocimetry (wOFV) to common experimental error sources

Wayne E. Page, Gauresh Raj Jassal, Bryan Eric Schmidt, Jeffrey A. Sutton
5 citations
Measurement Science and Technology
Flow Measurement and Analysis
1.35
article

Sensitivity of wavelet-based optical flow velocimetry (wOFV) to common experimental error sources

Wayne E. Page, Gauresh Raj Jassal, Bryan Eric Schmidt, Jeffrey A. Sutton
article en
5 citations

Abstract

Abstract The influence of several potential error sources and non-ideal experimental effects on the accuracy of a wavelet-based optical flow velocimetry (wOFV) method when applied to tracer particle images is evaluated using data from a series of synthetic flows. Out-of-plane particle displacements, severe image noise, laser sheet thickness reduction, and image intensity non-uniformity are shown to decrease the accuracy of wOFV in a similar manner to correlation-based particle image velocimetry (PIV). For the error sources tested, wOFV displays a similar or slightly increased sensitivity compared to PIV, but the wOFV results are still more accurate than PIV when the magnitude of the non-ideal effects remain within expected experimental bounds. For the majority of test cases, the results are significantly improved by using image pre-processing filters and the magnitude of improvement is consistent between wOFV and PIV. Flow divergence does not appear to have an appreciable effect on the accuracy of wOFV velocity estimation, even though the underlying fluid transport equation on which wOFV is based implicitly assumes that the motion is divergence-free. This is a significant finding for the broader applicability of planar velocimetry measurements using wOFV. Finally, it is noted that the accuracy of wOFV is not reduced notably in regions of the image between tracer particles, as long as the overall seeding density is not too sparse i.e. below 0.02 particles per pixel. This explicitly demonstrates that wOFV (when applied to particle images) yields an accurate whole field measurement, and not only at or adjacent to the discrete particle locations.

Measurement Science and TechnologyVol. 36(1)
The Ohio State University (US), Case Western Reserve University (US)
Division of Chemical, Bioengineering, Environmental, and Transport Systems, Air Force Office of Scientific Research
Openalex Percentile: Top 22%
Flow Measurement and Analysis
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.