Analysis of the left atrial appendage function by intracardiac echocardiography in patients with atrial fibrillation

Abstract Introduction Intracardiac echocardiography (ICE) is frequently performed during catheter ablation procedures in order to guide the transseptal puncture and has been recently used to evaluate the morphology of the LAA. Purpose The objective of this study was to evaluate the feasibility of using an ICE catheter placed in the coronary sinus (CS) to delineate the LAA function during catheter ablation for atrial fibrillation. Methods We included 21 consecutive patients (age 62±9 years, 5 women, 6 paroxysmal AF) who underwent catheter ablation for AF. An 8-Fr phased-array ICE catheter was used to obtain images of the LAA, while in sinus rhythm. The LAA was visualized with the ICE probe placed sequentially in the left atrium (LA, Figure A), with the ultrasound section plane parallel to the long axis of the left ventricle (LV), and in the CS, with the ultrasound section plane perpendicular to the LV long axis (Figure B). LAA emptying flow velocity, and LAA fractional area change (FAC) were used to evaluate LAA function. There were no procedural complications. Results ICE imaging was possible in all cases. The LAA peak flow velocity was similar when the ICE catheter was placed in the LA and in the CS (64±7 cm/s and 62±5cm/s respectively, P=NS). The LAA FAC was significantly lower when the ICE catheter was placed in the CS when compared to an LA location (14±6% vs 36±14%; P<0.001). The LAA FAC measured from the LA correlated with the mitral annular plane systolic excursion while the LAA FAC measured from the CS did not. Thus, LAA contraction in a plane perpendicular to the LV long axis is independent of the LV longitudinal contraction. These results suggest that in our patient group most of the LAA contraction was due to the longitudinal movement of the LV base during systole and diastole. Conclusions Imaging of LAA using an ICE probe positioned in the LA and CS was feasible in all cases. The LV longitudinal contraction appears to impact the LAA function.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.798
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the left atrial appendage function by intracardiac echocardiography in patients with atrial fibrillation

Giorgia Coșeriu, Dan Corneliu Blendea, Moussa Mansour, Mădălina Patricia Moldovan et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

Analysis of the left atrial appendage function by intracardiac echocardiography in patients with atrial fibrillation

Giorgia Coșeriu, Dan Corneliu Blendea, Moussa Mansour, Mădălina Patricia Moldovan, C A Eotvos, Teodora Avram, Roxana-Daiana Lazar, A Burde, P Tentea, Adriana Sarb, Sorin Pop, Iulia-Georgiana Zehan, Lucian Constantin MOCAN
article en

Abstract

Abstract Introduction Intracardiac echocardiography (ICE) is frequently performed during catheter ablation procedures in order to guide the transseptal puncture and has been recently used to evaluate the morphology of the LAA. Purpose The objective of this study was to evaluate the feasibility of using an ICE catheter placed in the coronary sinus (CS) to delineate the LAA function during catheter ablation for atrial fibrillation. Methods We included 21 consecutive patients (age 62±9 years, 5 women, 6 paroxysmal AF) who underwent catheter ablation for AF. An 8-Fr phased-array ICE catheter was used to obtain images of the LAA, while in sinus rhythm. The LAA was visualized with the ICE probe placed sequentially in the left atrium (LA, Figure A), with the ultrasound section plane parallel to the long axis of the left ventricle (LV), and in the CS, with the ultrasound section plane perpendicular to the LV long axis (Figure B). LAA emptying flow velocity, and LAA fractional area change (FAC) were used to evaluate LAA function. There were no procedural complications. Results ICE imaging was possible in all cases. The LAA peak flow velocity was similar when the ICE catheter was placed in the LA and in the CS (64±7 cm/s and 62±5cm/s respectively, P=NS). The LAA FAC was significantly lower when the ICE catheter was placed in the CS when compared to an LA location (14±6% vs 36±14%; P<0.001). The LAA FAC measured from the LA correlated with the mitral annular plane systolic excursion while the LAA FAC measured from the CS did not. Thus, LAA contraction in a plane perpendicular to the LV long axis is independent of the LV longitudinal contraction. These results suggest that in our patient group most of the LAA contraction was due to the longitudinal movement of the LV base during systole and diastole. Conclusions Imaging of LAA using an ICE probe positioned in the LA and CS was feasible in all cases. The LV longitudinal contraction appears to impact the LAA function.

European Heart JournalVol. 45(Supplement_1)
Harvard University (US), University of Agricultural Sciences and Veterinary Medicine of Cluj-Napoca (RO), Massachusetts General Hospital (US)
Openalex Percentile: Top 65%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.