Safety and efficacy of ultra-long intermediate-power ablation for outflow tract ventricular arrhythmia arising from the left ventricular summit

Abstract Background Radiofrequency ablation (RFA) has been effective in managing premature ventricular contractions (PVCs). Despite improvement in ablation techniques, recurrence remains high for LV summit PVCs. Epicardial ablation here is often precluded due to fat and proximity to coronaries, thus, aggressive but safe endocardial options are needed. Purpose To evaluate the safety and effectiveness of ultra-long ablation (>240 seconds) duration for refractory LV summit PVCs. Methods Patients with deep intramural LV summit PVCs were identified by lack of PVC elimination or late (>60 s suppression) and recurrence post-lesion under the left aortic sinus of Valsalva. We included patients who received the longest RFA of at least 240 seconds (maximum 15 minutes). RFA power was titrated slowly from 20 to 35W, carefully ensuring that the impedance drop did not exceed 12 ohms. Acute procedure success was defined as clinical PVC suppression for ≥60 minutes after the last lesion. Short-term success was defined as symptom improvement, ejection fraction (EF) recovery, and drop in PVC burden at 3 months. Results Twenty patients (59.5 ± 16.4 years, 55% male) were included. Baseline features are shown in Table 1. All RFA were delivered endocardially. No steam pops were noted. PVC burden was significantly lower at 3-month follow-up (P< 0.01), Figure 1A. Most patients had a normal ejection fraction (EF) at baseline; thus, no significant difference change in EF was observed (Figure 1B). One complication was recorded, which was tamponade likely caused by coronary sinus dissection requiring pericardiocentesis. Acute success was achieved in 95.0% of the cases, and all cases followed at 3 months (18/18) achieved short-term success. Conclusion Ultra-long duration RFA with lesions ≥ 240 seconds at 35W per lesion for LV summit PVCs appeared to be safe and effective in achieving acute and short-term success. The lack of acute suppression should not discourage operators, as there seems to be delayed suppression in some cases. Careful monitoring of biophysics is paramount when attempting this technique.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.686
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety and efficacy of ultra-long intermediate-power ablation for outflow tract ventricular arrhythmia arising from the left ventricular summit

Pragyat Futela, Konstantinos C. Siontis, Gurukripa Narayan Kowlgi, Qiying Dai et al.
European Heart Journal
Cardiac Arrhythmias and Treatments
article

Safety and efficacy of ultra-long intermediate-power ablation for outflow tract ventricular arrhythmia arising from the left ventricular summit

Pragyat Futela, Konstantinos C. Siontis, Gurukripa Narayan Kowlgi, Qiying Dai, Anuja Gupta, Lohit Garg, A J Deshmukh, fatima m ezzedine
article en

Abstract

Abstract Background Radiofrequency ablation (RFA) has been effective in managing premature ventricular contractions (PVCs). Despite improvement in ablation techniques, recurrence remains high for LV summit PVCs. Epicardial ablation here is often precluded due to fat and proximity to coronaries, thus, aggressive but safe endocardial options are needed. Purpose To evaluate the safety and effectiveness of ultra-long ablation (>240 seconds) duration for refractory LV summit PVCs. Methods Patients with deep intramural LV summit PVCs were identified by lack of PVC elimination or late (>60 s suppression) and recurrence post-lesion under the left aortic sinus of Valsalva. We included patients who received the longest RFA of at least 240 seconds (maximum 15 minutes). RFA power was titrated slowly from 20 to 35W, carefully ensuring that the impedance drop did not exceed 12 ohms. Acute procedure success was defined as clinical PVC suppression for ≥60 minutes after the last lesion. Short-term success was defined as symptom improvement, ejection fraction (EF) recovery, and drop in PVC burden at 3 months. Results Twenty patients (59.5 ± 16.4 years, 55% male) were included. Baseline features are shown in Table 1. All RFA were delivered endocardially. No steam pops were noted. PVC burden was significantly lower at 3-month follow-up (P< 0.01), Figure 1A. Most patients had a normal ejection fraction (EF) at baseline; thus, no significant difference change in EF was observed (Figure 1B). One complication was recorded, which was tamponade likely caused by coronary sinus dissection requiring pericardiocentesis. Acute success was achieved in 95.0% of the cases, and all cases followed at 3 months (18/18) achieved short-term success. Conclusion Ultra-long duration RFA with lesions ≥ 240 seconds at 35W per lesion for LV summit PVCs appeared to be safe and effective in achieving acute and short-term success. The lack of acute suppression should not discourage operators, as there seems to be delayed suppression in some cases. Careful monitoring of biophysics is paramount when attempting this technique.

European Heart JournalVol. 45(Supplement_1)
Mayo Clinic Hospital (US), University of Colorado Anschutz Medical Campus (US)
Openalex Percentile: Top 66%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.