Novel parameters for micra transcatheter pacing system implantation on the right ventricular mid-septum

Abstract Background No procedural parameters for Micra transcatheter pacing system (Micra TPS) implantation on the right ventricular mid-septum have been established though it is encouraged for safety. Purpose We aimed to investigate procedural predictors for Micra TPS implantation on the ventricular mid-septum. Methods This is a single-center, retrospective and observational study. Eighty-two patients who underwent Micra TPS implantation were enrolled. The implantation sites of the ventricular septum were classified into basal, mid and apical-septum in the right anterior oblique 35° image. Predictors for mid-septal implantation were evaluated using univariable and multivariable logistic regression analysis which involved explanatory variables considered clinically important. The explanatory variables included the angle between the axis of a device cup of a delivery catheter and the tangent of the ventricular septum in the left anterior oblique 45° image (defined as angle θ). The diagnostic cut-off value of the significant predictor for mid-septal Micra implantation was assessed using receiver operating characteristic (ROC) curve analysis. Results Micra TPS was implanted on the ventricular mid-septum in 61 patients (74.4%), the apical-septum in 21 patients (25.6%), and the basal-septum in no patients. In univariable logistic regression analysis, each angle θ and α-loop shape appearance of a delivery catheter was significantly associated with mid-septal implantation (Odds ratio [OR], 1.1; 95% confidential interval [CI], 1.02-1.10; P=0.002, and OR, 4.6; 95% CI, 1.63-13.6; P=0.005, respectively). After multivariable adjustment, both angle θ and α-loop shape appearance were independently associated with mid-septal implantation (adjusted OR, 1.1; 95% CI, 1.01-1.09; P=0.010, and adjusted OR, 3.3; 95% CI, 1.01-11.4; P=0.048, respectively). Because no Micra TPS was implanted on the basal-septum, an ROC curve for binary outcome of mid-septal and apical-septal implantation was drawn. The ROC curve showed a cut-off value of angle θ for Micra TPS implantation on the ventricular mid-septum was 22° with high sensitivity and specificity at 80.0% and 70.0% (area under the curve= 0.781). Conclusion The angle θ ≧ 22°and the α-loop shape appearance of a delivery catheter may be useful predictors for Micra TPS implantation on the ventricular mid-septum.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.427
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel parameters for micra transcatheter pacing system implantation on the right ventricular mid-septum

М. Б. Пак, Takashi Yamasaki, Ken Kakita, Takashi Hattori
European Heart Journal
Cardiac pacing and defibrillation studies
article

Novel parameters for micra transcatheter pacing system implantation on the right ventricular mid-septum

М. Б. Пак, Takashi Yamasaki, Ken Kakita, Takashi Hattori
article en

Abstract

Abstract Background No procedural parameters for Micra transcatheter pacing system (Micra TPS) implantation on the right ventricular mid-septum have been established though it is encouraged for safety. Purpose We aimed to investigate procedural predictors for Micra TPS implantation on the ventricular mid-septum. Methods This is a single-center, retrospective and observational study. Eighty-two patients who underwent Micra TPS implantation were enrolled. The implantation sites of the ventricular septum were classified into basal, mid and apical-septum in the right anterior oblique 35° image. Predictors for mid-septal implantation were evaluated using univariable and multivariable logistic regression analysis which involved explanatory variables considered clinically important. The explanatory variables included the angle between the axis of a device cup of a delivery catheter and the tangent of the ventricular septum in the left anterior oblique 45° image (defined as angle θ). The diagnostic cut-off value of the significant predictor for mid-septal Micra implantation was assessed using receiver operating characteristic (ROC) curve analysis. Results Micra TPS was implanted on the ventricular mid-septum in 61 patients (74.4%), the apical-septum in 21 patients (25.6%), and the basal-septum in no patients. In univariable logistic regression analysis, each angle θ and α-loop shape appearance of a delivery catheter was significantly associated with mid-septal implantation (Odds ratio [OR], 1.1; 95% confidential interval [CI], 1.02-1.10; P=0.002, and OR, 4.6; 95% CI, 1.63-13.6; P=0.005, respectively). After multivariable adjustment, both angle θ and α-loop shape appearance were independently associated with mid-septal implantation (adjusted OR, 1.1; 95% CI, 1.01-1.09; P=0.010, and adjusted OR, 3.3; 95% CI, 1.01-11.4; P=0.048, respectively). Because no Micra TPS was implanted on the basal-septum, an ROC curve for binary outcome of mid-septal and apical-septal implantation was drawn. The ROC curve showed a cut-off value of angle θ for Micra TPS implantation on the ventricular mid-septum was 22° with high sensitivity and specificity at 80.0% and 70.0% (area under the curve= 0.781). Conclusion The angle θ ≧ 22°and the α-loop shape appearance of a delivery catheter may be useful predictors for Micra TPS implantation on the ventricular mid-septum.

European Heart JournalVol. 45(Supplement_1)
Ijinkai Takeda General Hospital (JP)
Openalex Percentile: Top 66%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.