Predictor of A4-amplitude using preprocedural electrocardiography in patients with leadless pacemakers

Abstract Background Based on the historical studies of leadless pacemakers (LP), high atrio-ventricular synchrony (AVS) with mechanical sensing-based VDD pacing is largely influenced by A4-amplitude. A limited study investigated the predictors of A4-amplitude using clinical and echocardiographic parameters. Objective This study aimed to investigate the predictors of A4-amplitude preoperatively to select patients who could benefit the most from AVS among patients with VDD LPs. Methods Data from patients who received VDD LP implantations from November 2021 to August 2023 at our institution were analyzed. Twelve-lead electrocardiography and transthoracic echocardiography were performed before VDD LP implantations. To assess the electrical indices associated with the A4-signal, the electrocardiographic morphological P-wave parameters were analyzed including the P-wave duration, P-wave amplitude, maximum deflection index (MDI), and P-wave dispersion. Results A total of 50 patients who underwent VDD LP implantations (median age, 84 years; 64% male) were included and divided into two groups based on the median value of A4-amplitude, the high-A4 group (A4-amplitude >2.5m/s2, n=26) and low-A4 group (A4-amplitude ≤2.5m/s2, n=24). There was a significant difference between the high-A4 and low-A4 groups in the LVEF (P=0.01), P-wave dispersion (P=0.01), and MDI (P<0.001). A multivariate logistic analysis revealed that a lower MDI was an independent predictor of a high A4-amplitude (odds ratio: 0.78, 95% confidence interval: 0.67 to 0.92; P=0.003). Conclusion Preoperative electrocardiographic evaluations of the P-wave morphology may be useful for predicting A4-amplitude. The MDI was the only independent A4-amplitude predictor that seemed promising for selecting VDD LP patients.abstract figure

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.644
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Predictor of A4-amplitude using preprocedural electrocardiography in patients with leadless pacemakers

Takuya Tomomori, Aiko Okamura, Kazuyoshi Yamamoto, Kazufumi Nakamura et al.
European Heart Journal
Cardiac Imaging and Diagnostics
article

Predictor of A4-amplitude using preprocedural electrocardiography in patients with leadless pacemakers

Takuya Tomomori, Aiko Okamura, Kazuyoshi Yamamoto, Kazufumi Nakamura, Akinori Takami, Masahiko Kato, S Kawatani, Yasuhito Kotake
article en

Abstract

Abstract Background Based on the historical studies of leadless pacemakers (LP), high atrio-ventricular synchrony (AVS) with mechanical sensing-based VDD pacing is largely influenced by A4-amplitude. A limited study investigated the predictors of A4-amplitude using clinical and echocardiographic parameters. Objective This study aimed to investigate the predictors of A4-amplitude preoperatively to select patients who could benefit the most from AVS among patients with VDD LPs. Methods Data from patients who received VDD LP implantations from November 2021 to August 2023 at our institution were analyzed. Twelve-lead electrocardiography and transthoracic echocardiography were performed before VDD LP implantations. To assess the electrical indices associated with the A4-signal, the electrocardiographic morphological P-wave parameters were analyzed including the P-wave duration, P-wave amplitude, maximum deflection index (MDI), and P-wave dispersion. Results A total of 50 patients who underwent VDD LP implantations (median age, 84 years; 64% male) were included and divided into two groups based on the median value of A4-amplitude, the high-A4 group (A4-amplitude >2.5m/s2, n=26) and low-A4 group (A4-amplitude ≤2.5m/s2, n=24). There was a significant difference between the high-A4 and low-A4 groups in the LVEF (P=0.01), P-wave dispersion (P=0.01), and MDI (P<0.001). A multivariate logistic analysis revealed that a lower MDI was an independent predictor of a high A4-amplitude (odds ratio: 0.78, 95% confidence interval: 0.67 to 0.92; P=0.003). Conclusion Preoperative electrocardiographic evaluations of the P-wave morphology may be useful for predicting A4-amplitude. The MDI was the only independent A4-amplitude predictor that seemed promising for selecting VDD LP patients.abstract figure

European Heart JournalVol. 45(Supplement_1)
Tottori University Hospital (JP), Tottori Prefectural Central Hospital (JP)
Medtronic Japan
Openalex Percentile: Top 68%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.