Design methodology and performance analysis of a novel cooling system for dense array CPV receivers

• The methodology to analyze the cooling system of a CPV receiver is presented. • A two-dimensional jet impingement cooling schema is used. • Three receivers’ sizes are analyzed and compared against microchannels system. • Larger receivers’ sizes are 0.6 % more efficient using the proposed scheme. • Maximum receiver temperature is 26 % lower than in microchannel systems. The electrical performance of a dense array concentrating photovoltaics (CPV) receiver is reduced by the increase of average temperature, and by a non-uniform temperature map due to a non-uniform illumination profile. This can be reversed by an effective cooling system that allows the CPV cells to operate at nominal temperatures, as well as by optimal cell control at electrical level. An analysis that considers the interdependence between thermal and electrical behavior is essential for obtaining realistic performance results. Hence, this study presents a methodology for analyzing the performance of a CPV receiver controlled with DC-DC converters which considers the interaction between thermal and electrical behavior. The methodology allows to optimize the design of a novel jet impingement cooling system used in the receiver. Additionally, the efficiency of three different sizes of CPV receivers cooled by two technologies, microchannels and jet impingement, are analyzed. The results show that maximum receiver efficiency did not coincide with the maximum heat extraction coefficient. The study confirmed that larger receiver sizes had lower efficiency due to the mismatch losses and resulted more efficient (0.6 %) using the proposed jet impingement cooling system compared to microchannels.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2024-10-28
DOI
https://doi.org/10.1016/j.solener.2024.113011
Citations
3
Primary Topic
solar cell performance optimization
Type
article
Field-Weighted Citation Impact
0.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design methodology and performance analysis of a novel cooling system for dense array CPV receivers

Alicia Crespo, Jérôme Barrau, Desideri Regany, Joan Rosell
3 citations
Solar Energy
solar cell performance optimization
0.63
article

Design methodology and performance analysis of a novel cooling system for dense array CPV receivers

Alicia Crespo, Jérôme Barrau, Desideri Regany, Joan Rosell
article en
3 citations

Abstract

• The methodology to analyze the cooling system of a CPV receiver is presented. • A two-dimensional jet impingement cooling schema is used. • Three receivers’ sizes are analyzed and compared against microchannels system. • Larger receivers’ sizes are 0.6 % more efficient using the proposed scheme. • Maximum receiver temperature is 26 % lower than in microchannel systems. The electrical performance of a dense array concentrating photovoltaics (CPV) receiver is reduced by the increase of average temperature, and by a non-uniform temperature map due to a non-uniform illumination profile. This can be reversed by an effective cooling system that allows the CPV cells to operate at nominal temperatures, as well as by optimal cell control at electrical level. An analysis that considers the interdependence between thermal and electrical behavior is essential for obtaining realistic performance results. Hence, this study presents a methodology for analyzing the performance of a CPV receiver controlled with DC-DC converters which considers the interaction between thermal and electrical behavior. The methodology allows to optimize the design of a novel jet impingement cooling system used in the receiver. Additionally, the efficiency of three different sizes of CPV receivers cooled by two technologies, microchannels and jet impingement, are analyzed. The results show that maximum receiver efficiency did not coincide with the maximum heat extraction coefficient. The study confirmed that larger receiver sizes had lower efficiency due to the mismatch losses and resulted more efficient (0.6 %) using the proposed jet impingement cooling system compared to microchannels.

Solar EnergyVol. 283
Universitat de Lleida (ES), Universitat Rovira i Virgili (ES)
Affordable and clean energy
Openalex Percentile: Top 31%
solar cell performance optimization
0.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design methodology and performance analysis of a novel cooling system for dense array CPV receivers — Alicia Crespo, Jérôme Barrau, et al. · Solar Energy (2024) | TGRS Research Map | TGRS