Plasma apixaban levels and thrombin generation assay in patients with atrial fibrillation with dose reduction criteria of apixaban

Abstract Background Off-label reduced-dose apixaban is commonly prescribed in patients with atrial fibrillation (AF). However, the pharmacokinetic data of apixaban according to the dosage and label is limited especially in those with dose reduction criteria of apixaban. Purpose We investigated the apixaban plasma concentration (PC) and thrombin generation assay (TGA) parameters across different apixaban dose settings. Methods We enrolled 398 non-valvular AF patients with more than single-dose reduction criteria of apixaban and divided them into three groups: (1) on-label standard dose (single dose-reduction criterion with standard-dose of apixaban 5mg twice daily, n=173); (2) off-label reduced-dose (single dose-reduction criterion with apixaban 2.5mg twice daily, n=61); and (3) on-label reduced-dose (two or more dose-reduction criteria with apixaban 2.5mg twice daily, n=164). Apixaban PC by anti-Xa assay and TGA parameters of these three groups were compared at the trough level. Results The on-label standard dose group showed a higher PC than the on-label reduced dose (124.7 vs. 80.3 ng/mL, p<0.001), and the on-label reduced dose exhibited a higher PC than the off-label reduced dose (80.3 vs. 53.2 ng/mL, p=0.031) (Figure). The TGA parameters displayed a similar pattern of differences, with the on-label standard dose group tends to show the least thrombogenic profiles (Figure). Lower creatinine clearance (CrCl), older age, and female sex were statistically significant predictors for a higher apixaban PC by multivariable regression model (p<0.001, p=0.043, and 0.023, respectively), and CrCl was the most influential variable to dichotomize apixaban PC in all three groups (Figure). Conclusions Off-label reduced-dose apixaban group exhibited significantly lower apixaban level than both on-label standard dose and on-label reduced-dose apixaban groups, suggesting the importance of adhering to current dose-reduction criteria for maintaining appropriate apixaban levels. Caution is particularly advised in off-label under-dosing for patients with high creatinine clearance. Further investigation into the impact of off-label under-dosing on clinical outcomes is essential to guide optimal therapeutic strategies.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.611
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plasma apixaban levels and thrombin generation assay in patients with atrial fibrillation with dose reduction criteria of apixaban

Eunsuk Choi, Seil Oh, Hyo‐Jeong Ahn, Soonil Kwon et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

Plasma apixaban levels and thrombin generation assay in patients with atrial fibrillation with dose reduction criteria of apixaban

Eunsuk Choi, Seil Oh, Hyo‐Jeong Ahn, Soonil Kwon, Min-Ju Yeo, S R Lee
article en

Abstract

Abstract Background Off-label reduced-dose apixaban is commonly prescribed in patients with atrial fibrillation (AF). However, the pharmacokinetic data of apixaban according to the dosage and label is limited especially in those with dose reduction criteria of apixaban. Purpose We investigated the apixaban plasma concentration (PC) and thrombin generation assay (TGA) parameters across different apixaban dose settings. Methods We enrolled 398 non-valvular AF patients with more than single-dose reduction criteria of apixaban and divided them into three groups: (1) on-label standard dose (single dose-reduction criterion with standard-dose of apixaban 5mg twice daily, n=173); (2) off-label reduced-dose (single dose-reduction criterion with apixaban 2.5mg twice daily, n=61); and (3) on-label reduced-dose (two or more dose-reduction criteria with apixaban 2.5mg twice daily, n=164). Apixaban PC by anti-Xa assay and TGA parameters of these three groups were compared at the trough level. Results The on-label standard dose group showed a higher PC than the on-label reduced dose (124.7 vs. 80.3 ng/mL, p<0.001), and the on-label reduced dose exhibited a higher PC than the off-label reduced dose (80.3 vs. 53.2 ng/mL, p=0.031) (Figure). The TGA parameters displayed a similar pattern of differences, with the on-label standard dose group tends to show the least thrombogenic profiles (Figure). Lower creatinine clearance (CrCl), older age, and female sex were statistically significant predictors for a higher apixaban PC by multivariable regression model (p<0.001, p=0.043, and 0.023, respectively), and CrCl was the most influential variable to dichotomize apixaban PC in all three groups (Figure). Conclusions Off-label reduced-dose apixaban group exhibited significantly lower apixaban level than both on-label standard dose and on-label reduced-dose apixaban groups, suggesting the importance of adhering to current dose-reduction criteria for maintaining appropriate apixaban levels. Caution is particularly advised in off-label under-dosing for patients with high creatinine clearance. Further investigation into the impact of off-label under-dosing on clinical outcomes is essential to guide optimal therapeutic strategies.

European Heart JournalVol. 45(Supplement_1)
Seoul National University (KR), New Generation University College (ET), Seoul National University Hospital (KR)
Good health and well-being
Openalex Percentile: Top 66%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.