Collision mapping enables accurate localization of the slow pathway in atrioventricular nodal reentrant tachycardia

Abstract Introduction Atrioventricular Node Reentry Tachycardia (AVNRT) is commonly treated with catheter ablation, with high success and low complication rates. However a small risk of complete AV block still remains. Recent studies could show that using collision map is a feasible approach in mapping the slow pathway. The aim of the current study is to show a reduction of the total ablation points needed to modify/ablate the slow pathway using the collision mapping compared to conventional 3D mapping guided slow pathway modulation/ablation and therefore minimize the risk of a complete heart block. Methods Patients diagnosed with AVNRT (n = 24) underwent collision mapping for slow pathway identification, compared to a historical cohort (n=76) using conventional mapping. For collision mapping a dynamic visualization of atrial propagation during sinus rhythm was condcted. Two propagation fronts were observed to collide at the triangle of Koch, one propagation through the slow and one through the fast pathway. The designated collision zone was considered ideal for catheter ablation (Figure 1). The endpoint after ablation in both groups was non-inducibility of AVNRTs. Results After propensity score matching the collision mapping group needed significantly fewer ablation impulses (2 (IQR 1 - 5) vs. 6 (IQR 2,5 - 11,5) p = 0.002) and shorter ablation time (p < 0.001) compared to the conventional group (Table 1). No significant differences were observed in procedure time (p = 0.209), fluoroscopy time (p = 0.296), or dose area product (p = 0.391). Conclusion Collision Mapping in AVNRT ablation showed a notable reduction in ablation points, suggesting enhanced procedural efficiency and safety.Figure 1Table1

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.635
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Collision mapping enables accurate localization of the slow pathway in atrioventricular nodal reentrant tachycardia

M Deserio, T Seewoester, Patrick Dilk, Sotirios Nedios et al.
European Heart Journal
Cardiac Arrhythmias and Treatments
article

Collision mapping enables accurate localization of the slow pathway in atrioventricular nodal reentrant tachycardia

M Deserio, T Seewoester, Patrick Dilk, Sotirios Nedios, Sabrina Oebel, Frank Lindemann, Andreas Bollmann, Kerstin Bode, Michael Feher
article en

Abstract

Abstract Introduction Atrioventricular Node Reentry Tachycardia (AVNRT) is commonly treated with catheter ablation, with high success and low complication rates. However a small risk of complete AV block still remains. Recent studies could show that using collision map is a feasible approach in mapping the slow pathway. The aim of the current study is to show a reduction of the total ablation points needed to modify/ablate the slow pathway using the collision mapping compared to conventional 3D mapping guided slow pathway modulation/ablation and therefore minimize the risk of a complete heart block. Methods Patients diagnosed with AVNRT (n = 24) underwent collision mapping for slow pathway identification, compared to a historical cohort (n=76) using conventional mapping. For collision mapping a dynamic visualization of atrial propagation during sinus rhythm was condcted. Two propagation fronts were observed to collide at the triangle of Koch, one propagation through the slow and one through the fast pathway. The designated collision zone was considered ideal for catheter ablation (Figure 1). The endpoint after ablation in both groups was non-inducibility of AVNRTs. Results After propensity score matching the collision mapping group needed significantly fewer ablation impulses (2 (IQR 1 - 5) vs. 6 (IQR 2,5 - 11,5) p = 0.002) and shorter ablation time (p < 0.001) compared to the conventional group (Table 1). No significant differences were observed in procedure time (p = 0.209), fluoroscopy time (p = 0.296), or dose area product (p = 0.391). Conclusion Collision Mapping in AVNRT ablation showed a notable reduction in ablation points, suggesting enhanced procedural efficiency and safety.Figure 1Table1

European Heart JournalVol. 45(Supplement_1)
Leipzig Heart Institute (DE)
Openalex Percentile: Top 66%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.