Conduction-System pacing Italian Network Group (C-SING): insights from a Nationwide Multicenter Observational Study

Abstract Background/Introduction Conduction system pacing (CSP), encompassing His bundle pacing (HBP) and left bundle branch area pacing (LBBAP), has gained prominence in treating bradycardia and heart failure in recent years. Despite its increasing utilization, data on real-world adoption of CSP are limited. Purpose The C-SING study aimed at assessing patient characteristics, implant success, procedural details, and safety of CSP when performed in routine clinical practice. Methods Periprocedural data from 27 experienced CSP centers across Italy were collected on patients undergoing CSP implantation for various indications between January 2021 and January 2024. Results The study comprised 1,317 patients (median age 78 years [interquartile range, 71-83], male 66.2%). Leading indications included atrioventricular (AV) block (40.8%), sinus node dysfunction (12.1%), atrial fibrillation with bradycardia (9.7%), AV node ablation (9.5%), and heart failure (12.5%). Pacemakers were implanted in 77.3% of patients, cardiac resynchronization devices in 21.7%, and implantable cardioverter-defibrillators in 1.0%. Stylet-driven and lumenless CSP leads were utilized in 64.7% and 35.3% of procedures, respectively. Final 12-lead ECG assessment revealed LBBAP capture in 88.7% patients, HBP in 8.4% (selective 4.2%, non-selective 4.2%), and no CSP capture in 3.0%, resulting in a 97.0% CSP lead implantation success rate. In patients with LBBAP, predominant capture types were left bundle branch pacing (19.6%), left posterior fascicular pacing (19.2%), and left septal fascicular pacing (14.8%). Comparing HBP to LBBAP, the latter showed shorter procedural time (60 minutes [45-80] vs. 70 minutes [60-95], p=0.003), but similar fluoroscopy time (6.0 minutes [3.3-10.8] vs. 6.1 minutes [4-10], p=0.735). Paced QRS duration was longer in LBBAP (118 ms [105-130]) compared to HBP (110 ms [101-122], p<0.001). LBBAP showed lower capture thresholds (0.6 V [0.5-0.9] @0.4 ms vs. 0.8 V [0.5-1.5] @1.0 ms, p<0.001) and higher R-wave sensing (10.7 mV [8-16] vs. 4.5 mV [2.4-9.9], p<0.001). The rate of periprocedural complications was higher in patients with LBBAP than HBP (7.3% vs. 1.8%, p=0.03), with the most frequent events being intraprocedural perforation into the left ventricular cavity during lead screwing (2.6%) and CSP lead dislodgment before hospital discharge (1.4%). These occurrences necessitated lead repositioning without additional complications. Conclusion CSP demonstrated feasibility as a primary pacing strategy for various indications in a real-world, multicenter setting. LBBAP, more frequently used than HBP, exhibited shorter procedural time and superior acute electrical parameters. LBBAP revealed a higher rate of minor procedural complications than HBP. Further investigations, supported by additional long-term outcome data, are essential to comprehensively assess CSP performance.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.701
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Conduction-System pacing Italian Network Group (C-SING): insights from a Nationwide Multicenter Observational Study

M Magnano, Luca Tomasi, Matteo Bertini, Giuseppe Patti et al.
European Heart Journal
Cardiac pacing and defibrillation studies
article

Conduction-System pacing Italian Network Group (C-SING): insights from a Nationwide Multicenter Observational Study

M Magnano, Luca Tomasi, Matteo Bertini, Giuseppe Patti, Matteo Baroni, Alessandro Paoletti Perini, Antonio Rapacciuolo, Mario Volpicelli, Lidia Poggio, P Palmisano, Umberto Startari, Luca De Mattia, Gabriele Dell’Era, P. Donateo, Giovanni Rovaris
article en

Abstract

Abstract Background/Introduction Conduction system pacing (CSP), encompassing His bundle pacing (HBP) and left bundle branch area pacing (LBBAP), has gained prominence in treating bradycardia and heart failure in recent years. Despite its increasing utilization, data on real-world adoption of CSP are limited. Purpose The C-SING study aimed at assessing patient characteristics, implant success, procedural details, and safety of CSP when performed in routine clinical practice. Methods Periprocedural data from 27 experienced CSP centers across Italy were collected on patients undergoing CSP implantation for various indications between January 2021 and January 2024. Results The study comprised 1,317 patients (median age 78 years [interquartile range, 71-83], male 66.2%). Leading indications included atrioventricular (AV) block (40.8%), sinus node dysfunction (12.1%), atrial fibrillation with bradycardia (9.7%), AV node ablation (9.5%), and heart failure (12.5%). Pacemakers were implanted in 77.3% of patients, cardiac resynchronization devices in 21.7%, and implantable cardioverter-defibrillators in 1.0%. Stylet-driven and lumenless CSP leads were utilized in 64.7% and 35.3% of procedures, respectively. Final 12-lead ECG assessment revealed LBBAP capture in 88.7% patients, HBP in 8.4% (selective 4.2%, non-selective 4.2%), and no CSP capture in 3.0%, resulting in a 97.0% CSP lead implantation success rate. In patients with LBBAP, predominant capture types were left bundle branch pacing (19.6%), left posterior fascicular pacing (19.2%), and left septal fascicular pacing (14.8%). Comparing HBP to LBBAP, the latter showed shorter procedural time (60 minutes [45-80] vs. 70 minutes [60-95], p=0.003), but similar fluoroscopy time (6.0 minutes [3.3-10.8] vs. 6.1 minutes [4-10], p=0.735). Paced QRS duration was longer in LBBAP (118 ms [105-130]) compared to HBP (110 ms [101-122], p<0.001). LBBAP showed lower capture thresholds (0.6 V [0.5-0.9] @0.4 ms vs. 0.8 V [0.5-1.5] @1.0 ms, p<0.001) and higher R-wave sensing (10.7 mV [8-16] vs. 4.5 mV [2.4-9.9], p<0.001). The rate of periprocedural complications was higher in patients with LBBAP than HBP (7.3% vs. 1.8%, p=0.03), with the most frequent events being intraprocedural perforation into the left ventricular cavity during lead screwing (2.6%) and CSP lead dislodgment before hospital discharge (1.4%). These occurrences necessitated lead repositioning without additional complications. Conclusion CSP demonstrated feasibility as a primary pacing strategy for various indications in a real-world, multicenter setting. LBBAP, more frequently used than HBP, exhibited shorter procedural time and superior acute electrical parameters. LBBAP revealed a higher rate of minor procedural complications than HBP. Further investigations, supported by additional long-term outcome data, are essential to comprehensively assess CSP performance.

European Heart JournalVol. 45(Supplement_1)
Università degli Studi del Piemonte Orientale “Amedeo Avogadro” (IT), University of Ferrara (IT), Santa Maria Nuova Hospital (IT), Cardinal Health (Australia) (AU), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), Ospedale Maggiore (IT), AULSS 2 Marca Trevigiana (IT), Provincia Autonoma di Trento (IT), Azienda Ospedaliera San Gerardo (IT), CTO Andrea Alesini (IT), Federico II University Hospital (IT), Azienda Ospedaliero Universitaria Maggiore della Carita (IT), National Research Council (RO), Metropolitana Milanese (Italy) (IT), Piedmont University (US)
Good health and well-being
Openalex Percentile: Top 66%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.