A meta-analysis of the safety and efficacy of pulsed-field versus conventional thermal ablation for atrial fibrillation

Abstract Background Since pulsed-field ablation (PFA) specifically targets myocardial tissue, it has become a cutting-edge substitute for radiofrequency (RF) and cryoablation. Purpose We aim to compare the safety and efficacy of PFA vs thermal ablation for AF ablation. Methods We conducted a systematic review and meta-analysis synthesizing randomized controlled trials (RCTs) and observational comparative studies, which were retrieved by systematically searching: PubMed, EMBASE, Web of Science, SCOPUS, and Cochrane through September 2023. RevMan version 5.4 software was used to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD) with a 95% confidence interval (CI). Results Seventeen studies with a total of 2,255 patients were included. PFA was significantly associated with a decreased AF recurrence (RR: 0.65, 95% CI [0.51, 0.84], P= 0.0010) but not any arrhythmia recurrence (RR: 0.87, 95% CI [0.69, 1.09], P= 0.22). Also, PFA was significantly associated with decreased total procedure time (MD: -15.15, 95% CI [-20.23, -10.07], P< 0.00001) and heart rate (MD: -7.56, 95% CI [-12.78, -2.34], P= 0.005); however, there was no significant difference between PFA and thermal ablation in fluoroscopy time (MD: 2.83, 95% CI [-0.38, 6.04], P= 0.08). PFA decreased phrenic nerve palsy (RR: 0.38, 95% CI [0.15, 0.98], P= 0.05) and esophageal lesions (RR: 0.09, 95% CI [0.01, 0.69], P= 0.02); however, PFA was significantly associated with increased pericardial tamponade (RR: 6.14 with 95% CI [1.43, 26.33], P= 0.01). Conclusion PFA was significantly associated with decreased AF recurrence, heart rate, total procedure time, phrenic nerve palsy, esophageal lesion, and increased incidence of pericardial tamponade compared with thermal ablation. However, current evidence is mainly weighted by observational studies, requiring further large-scale randomized trials.Figure

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.361
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A meta-analysis of the safety and efficacy of pulsed-field versus conventional thermal ablation for atrial fibrillation

Mohamed A. Ellabban, Mohamed Abuelazm, M. Amin Arnaout, Basel Abdelazeem et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

A meta-analysis of the safety and efficacy of pulsed-field versus conventional thermal ablation for atrial fibrillation

Mohamed A. Ellabban, Mohamed Abuelazm, M. Amin Arnaout, Basel Abdelazeem, Ahmed Abdelmoniem Ibrahim, Aamir Nazir, Aya Moustafa Aboutaleb, A. M. Amin, Mohamed Abouzid, Hossam Elbenawi
article en

Abstract

Abstract Background Since pulsed-field ablation (PFA) specifically targets myocardial tissue, it has become a cutting-edge substitute for radiofrequency (RF) and cryoablation. Purpose We aim to compare the safety and efficacy of PFA vs thermal ablation for AF ablation. Methods We conducted a systematic review and meta-analysis synthesizing randomized controlled trials (RCTs) and observational comparative studies, which were retrieved by systematically searching: PubMed, EMBASE, Web of Science, SCOPUS, and Cochrane through September 2023. RevMan version 5.4 software was used to pool dichotomous data using risk ratio (RR) and continuous data using mean difference (MD) with a 95% confidence interval (CI). Results Seventeen studies with a total of 2,255 patients were included. PFA was significantly associated with a decreased AF recurrence (RR: 0.65, 95% CI [0.51, 0.84], P= 0.0010) but not any arrhythmia recurrence (RR: 0.87, 95% CI [0.69, 1.09], P= 0.22). Also, PFA was significantly associated with decreased total procedure time (MD: -15.15, 95% CI [-20.23, -10.07], P< 0.00001) and heart rate (MD: -7.56, 95% CI [-12.78, -2.34], P= 0.005); however, there was no significant difference between PFA and thermal ablation in fluoroscopy time (MD: 2.83, 95% CI [-0.38, 6.04], P= 0.08). PFA decreased phrenic nerve palsy (RR: 0.38, 95% CI [0.15, 0.98], P= 0.05) and esophageal lesions (RR: 0.09, 95% CI [0.01, 0.69], P= 0.02); however, PFA was significantly associated with increased pericardial tamponade (RR: 6.14 with 95% CI [1.43, 26.33], P= 0.01). Conclusion PFA was significantly associated with decreased AF recurrence, heart rate, total procedure time, phrenic nerve palsy, esophageal lesion, and increased incidence of pericardial tamponade compared with thermal ablation. However, current evidence is mainly weighted by observational studies, requiring further large-scale randomized trials.Figure

European Heart JournalVol. 45(Supplement_1)
University of Aleppo (SY), Poznan University of Medical Sciences (PL), Mayo Clinic (US), King Edward Medical University (PK), Mansoura University (EG), Zagazig University (EG), Tanta University (EG), West Virginia University Hospitals (US), Al-Azhar University (ID), Menoufia University (EG)
Openalex Percentile: Top 66%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.