A novel device for electrocardiographic imaging

Abstract Background Electrocardiographic imaging (ECGi) is a non-invasive imaging tool that allows 3D visualization and characterization of the electrical activity of the heart from measurements on the body surface by solving the so called "inverse problem of electrocardiography". This method helps overcome the limitations of the conventional12-lead ECG in diagnosing and locating heart arrythmias. We developed a textile 34-electrode imageless device (with no need for MRI or CT-scan). Purpose We aim to evaluate the feasibility and safety of the use of a novel textile imageless 34-electrode device for recording ECGi for identification of electrical activity of the heart. Methods and results The performance of a prototype data acquisition system (DAS) was evaluated in 158 individuals. Tests were conducted in three hospitals. The mean age was 43.32 years old (±17.44); mean height 167.31cm (±18.33); mean weight 70kg (±15.68). Almost 88% of the patients were in sinus rhythm. The relative frequencies of the targeted pathologies are listed in Figure 1. The collection of cardiac signals and posterior representation in virtual reality of a stereoscopic, holographic 3D-360º map, was achieved in 100% of the patients. Figure 2 shows the textile hardware with the silver dry electrodes and a screenshot of the software with an example of a voltage map in a patient in sinus rhythm. There were no adverse effects reported. The DAS is composed of 34 electrodes, being their distribution representative of the electrical activity on the torso. Several studies have discussed the minimum number of electrodes on the torso of the patient required to characterize the heart potentials from the electrical potentials on the torso surface through the inverse problem (1,2). We highlight that the representativeness condition of the electrical activity on the torso is crucial to appropriately estimate cardiac activity with the minimum number of leads on the DAS. Conclusion The use of a novel textile imageless 34-electrode device for recording ECGi for identification of electrical activity of the heart is feasible and safe.Targeted rhythmHardware and software

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.358
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel device for electrocardiographic imaging

Victoria Galizia Brito, Frelyn Ocampo, Camilo Pineda, P. Bravo et al.
European Heart Journal
Non-Invasive Vital Sign Monitoring
article

A novel device for electrocardiographic imaging

Victoria Galizia Brito, Frelyn Ocampo, Camilo Pineda, P. Bravo, J A Cabrera Rodriguez, J.M. Segui, Carlos Grande Morales, Tomás Datino, V Gallego Sanchez
article en

Abstract

Abstract Background Electrocardiographic imaging (ECGi) is a non-invasive imaging tool that allows 3D visualization and characterization of the electrical activity of the heart from measurements on the body surface by solving the so called "inverse problem of electrocardiography". This method helps overcome the limitations of the conventional12-lead ECG in diagnosing and locating heart arrythmias. We developed a textile 34-electrode imageless device (with no need for MRI or CT-scan). Purpose We aim to evaluate the feasibility and safety of the use of a novel textile imageless 34-electrode device for recording ECGi for identification of electrical activity of the heart. Methods and results The performance of a prototype data acquisition system (DAS) was evaluated in 158 individuals. Tests were conducted in three hospitals. The mean age was 43.32 years old (±17.44); mean height 167.31cm (±18.33); mean weight 70kg (±15.68). Almost 88% of the patients were in sinus rhythm. The relative frequencies of the targeted pathologies are listed in Figure 1. The collection of cardiac signals and posterior representation in virtual reality of a stereoscopic, holographic 3D-360º map, was achieved in 100% of the patients. Figure 2 shows the textile hardware with the silver dry electrodes and a screenshot of the software with an example of a voltage map in a patient in sinus rhythm. There were no adverse effects reported. The DAS is composed of 34 electrodes, being their distribution representative of the electrical activity on the torso. Several studies have discussed the minimum number of electrodes on the torso of the patient required to characterize the heart potentials from the electrical potentials on the torso surface through the inverse problem (1,2). We highlight that the representativeness condition of the electrical activity on the torso is crucial to appropriately estimate cardiac activity with the minimum number of leads on the DAS. Conclusion The use of a novel textile imageless 34-electrode device for recording ECGi for identification of electrical activity of the heart is feasible and safe.Targeted rhythmHardware and software

European Heart JournalVol. 45(Supplement_1)
Hospital Universitario Quirónsalud Madrid (ES), Hospital Universitario Son Espases (ES)
Openalex Percentile: Top 83%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.