Shocking. Expectations and beliefs on life with a defibrillator

Abstract Introduction Although implantable cardioverter defibrillator (ICD) and implantable cardiac resynchronization therapy defibrillator (CRT-D) play a life-saving role, patient’s understanding of their device warrants a thorough analysis and implementation of educational programs. Purpose To study patient’s understanding and expectations regarding ICDs and CRT-Ds. Methods Using convenience sampling method, this cross-sectional study was conducted on a sample of 129 patients referred to the pacing clinic or emergency department of a tertiary hospital, from October to November of 2023. The data were collected directly from the patient's clinical files and through in person or phone interviews conducted according to a pre-specified inquiry form, that included Florida Shock Anxiety Scale and the Implantable Cardioverter-Defibrillator Concerns questionnaire. Statistical analysis was performed using SPSS 29. Results Among the 129 patients that agreed to answer the full inquiry: the majority were male (79.8%) and the average age was 63.3 ± 10.6 years [25; 80]. Comorbidities were: 89.1% heart failure, 81.4% dyslipidemia, 77.5% hypertension, 55.0% ischemic heart disease, 51.9% atrial fibrillation. Device was an ICD in 59.7% or a CRT-D in 40.3% of the patients; the majority (84.5%) received the device in primary prevention, among these, ischemic disease (48.1%) and dilated myocardiopathy (36.4%) were the top substrates. Of the study patients, 70.5% claim to have never experienced any device shocks. Regarding the Florida Shock Anxiety Scale, the average score was 1.9 ± 0.6; among the 10 items queried, the sentences with the higher score (more worried) were: "I worry about the ICD not firing sometime when it should" (2.7 ± 1.1) and "When I notice my heart beating rapidly, I worry that the ICD will fire" (2.5 ± 1.0); while those with lower score (less worried) were: "I am afraid to touch others for fear I’ll shock them if the ICD fires" (1.4 ± 0.6) and "I do not engage in sexual activities because it may cause my ICD to fire" (1.4 ± 0.6). On the Implantable Cardioverter-Defibrillator Concerns questionnaire, the average score was 2.0 ± 0.5; among the 20 items queried, those with the higher score (more worried) were: "My ICD not working when I need it to" (2.8 ± 0.9) and "Problems occurring with my ICD, eg, battery failure" (2.7 ± 0.8); while those with lower score (less worried) were: "The amount of time I spend thinking about my heart condition and having an ICD" (1.3 ± 0.5) and "Being a burden on my partner / family" (1.2 ± 0.5). Conclusion The results obtained from this analysis are of particular interest to better define patient’s expectations regarding defibrillator devices; ranking higher on aspects that worry patients are those related with device malfunction and physical activity leading to shock firing; on the other end of the spectrum, patients seldom worry about shock transmission to others and the time spent thinking about their disease.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.430
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shocking. Expectations and beliefs on life with a defibrillator

B Gracia, Fausto José Pinto, José Honório de Almeida Palma da Fonseca, A M Martins et al.
European Heart Journal
Cardiac pacing and defibrillation studies
article

Shocking. Expectations and beliefs on life with a defibrillator

B Gracia, Fausto José Pinto, José Honório de Almeida Palma da Fonseca, A M Martins, David Ferreira, João de Sousa, Caroline Barros Oliveira, Andreia Magalhães, Pedro Marques, M Raposo, C Gregorio
article en

Abstract

Abstract Introduction Although implantable cardioverter defibrillator (ICD) and implantable cardiac resynchronization therapy defibrillator (CRT-D) play a life-saving role, patient’s understanding of their device warrants a thorough analysis and implementation of educational programs. Purpose To study patient’s understanding and expectations regarding ICDs and CRT-Ds. Methods Using convenience sampling method, this cross-sectional study was conducted on a sample of 129 patients referred to the pacing clinic or emergency department of a tertiary hospital, from October to November of 2023. The data were collected directly from the patient's clinical files and through in person or phone interviews conducted according to a pre-specified inquiry form, that included Florida Shock Anxiety Scale and the Implantable Cardioverter-Defibrillator Concerns questionnaire. Statistical analysis was performed using SPSS 29. Results Among the 129 patients that agreed to answer the full inquiry: the majority were male (79.8%) and the average age was 63.3 ± 10.6 years [25; 80]. Comorbidities were: 89.1% heart failure, 81.4% dyslipidemia, 77.5% hypertension, 55.0% ischemic heart disease, 51.9% atrial fibrillation. Device was an ICD in 59.7% or a CRT-D in 40.3% of the patients; the majority (84.5%) received the device in primary prevention, among these, ischemic disease (48.1%) and dilated myocardiopathy (36.4%) were the top substrates. Of the study patients, 70.5% claim to have never experienced any device shocks. Regarding the Florida Shock Anxiety Scale, the average score was 1.9 ± 0.6; among the 10 items queried, the sentences with the higher score (more worried) were: "I worry about the ICD not firing sometime when it should" (2.7 ± 1.1) and "When I notice my heart beating rapidly, I worry that the ICD will fire" (2.5 ± 1.0); while those with lower score (less worried) were: "I am afraid to touch others for fear I’ll shock them if the ICD fires" (1.4 ± 0.6) and "I do not engage in sexual activities because it may cause my ICD to fire" (1.4 ± 0.6). On the Implantable Cardioverter-Defibrillator Concerns questionnaire, the average score was 2.0 ± 0.5; among the 20 items queried, those with the higher score (more worried) were: "My ICD not working when I need it to" (2.8 ± 0.9) and "Problems occurring with my ICD, eg, battery failure" (2.7 ± 0.8); while those with lower score (less worried) were: "The amount of time I spend thinking about my heart condition and having an ICD" (1.3 ± 0.5) and "Being a burden on my partner / family" (1.2 ± 0.5). Conclusion The results obtained from this analysis are of particular interest to better define patient’s expectations regarding defibrillator devices; ranking higher on aspects that worry patients are those related with device malfunction and physical activity leading to shock firing; on the other end of the spectrum, patients seldom worry about shock transmission to others and the time spent thinking about their disease.

European Heart JournalVol. 45(Supplement_1)
Centro Hospitalar Lisboa Norte (PT), Hospital de Santa Maria (PT)
Openalex Percentile: Top 66%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.