Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter

3DStent is a novel rotational angiography imaging capable of 3D reconstruction and measuring stent area and diameter, without need for intravascular imaging. To compare 3DStent and OCT-derived stent area and diameter after PCI. Patients with de novo coronary lesions who underwent treatment with a single DES and evaluated by OCT and 3DStent were included. Stent area and diameter were measured by 3DStent, at abluminal, mid and endoluminal side and by OCT. From September 2023 to February 2024 six coronary lesions were analyzed. Post-PCI stent area measured by OCT was (mean ± standard deviation) 7.03 ± 2.85 mm<sup>2</sup> and by 3DStent 9.41 ± 2.79 mm<sup>2</sup>, 7.21 ± 2.23 mm<sup>2</sup> and 5.63 ± 1.83 mm<sup>2</sup> at abluminal, mid and endoluminal side, respectively. Stent diameter by OCT was 2.93 ± 0.58 mm, and by 3DStent 3.27 ± 0.50 mm, 2.86 ± 0.49 mm and 2.52 ± 0.45 mm at abluminal, mid and endoluminal side, respectively. Significant correlation was observed between OCT and 3DStent in relation to stent area (Exp(B) 3.35, mean of difference 0.19 ± 1.01 mm<sup>2</sup>, 95%CI -1.80-2.17 mm<sup>2</sup>, p < 0.001) and diameter (Exp(B) 3.18, mean difference - 0.07 ± 0.18 mm, 95%CI -0.43-0.30 mm, p < 0.001), particularly when 3DStent measurements performed at the mid side. Very high reproducibility was demonstrated by intra- and inter-observer analysis (r = 0.92 and r = 0.93 respectively). 3DStent appears to be an easy and reproducible tool to assess post-PCI stent area and diameter as compared to OCT.

Authors

Institutions

Publication Details

Journal
The International Journal of Cardiovascular Imaging
Published
2024-10-28
DOI
https://doi.org/10.1007/s10554-024-03268-8
Citations
2
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
1.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter

Giovanni Occhipinti, Manel Sabaté, Giulio Guagliumi, Andrea Alberto Ruberti et al.
2 citations
The International Journal of Cardiovascular Imaging
Coronary Interventions and Diagnostics
1.15
article

Agreement and reproducibility between 3DStent vs. Optical Coherence Tomography for evaluation of stent area and diameter

Giovanni Occhipinti, Manel Sabaté, Giulio Guagliumi, Andrea Alberto Ruberti, Liliane Ramus, Salvatore Brugaletta, Riccardo Rinaldi
article en
2 citations

Abstract

3DStent is a novel rotational angiography imaging capable of 3D reconstruction and measuring stent area and diameter, without need for intravascular imaging. To compare 3DStent and OCT-derived stent area and diameter after PCI. Patients with de novo coronary lesions who underwent treatment with a single DES and evaluated by OCT and 3DStent were included. Stent area and diameter were measured by 3DStent, at abluminal, mid and endoluminal side and by OCT. From September 2023 to February 2024 six coronary lesions were analyzed. Post-PCI stent area measured by OCT was (mean ± standard deviation) 7.03 ± 2.85 mm<sup>2</sup> and by 3DStent 9.41 ± 2.79 mm<sup>2</sup>, 7.21 ± 2.23 mm<sup>2</sup> and 5.63 ± 1.83 mm<sup>2</sup> at abluminal, mid and endoluminal side, respectively. Stent diameter by OCT was 2.93 ± 0.58 mm, and by 3DStent 3.27 ± 0.50 mm, 2.86 ± 0.49 mm and 2.52 ± 0.45 mm at abluminal, mid and endoluminal side, respectively. Significant correlation was observed between OCT and 3DStent in relation to stent area (Exp(B) 3.35, mean of difference 0.19 ± 1.01 mm<sup>2</sup>, 95%CI -1.80-2.17 mm<sup>2</sup>, p < 0.001) and diameter (Exp(B) 3.18, mean difference - 0.07 ± 0.18 mm, 95%CI -0.43-0.30 mm, p < 0.001), particularly when 3DStent measurements performed at the mid side. Very high reproducibility was demonstrated by intra- and inter-observer analysis (r = 0.92 and r = 0.93 respectively). 3DStent appears to be an easy and reproducible tool to assess post-PCI stent area and diameter as compared to OCT.

The International Journal of Cardiovascular ImagingVol. 40(12)
Departament de Salut (ES), Istituto Clinico Sant'Ambrogio (IT), Hospital Clínic de Barcelona (ES), Consorci Institut D'Investigacions Biomediques August Pi I Sunyer (ES), Universitat de Barcelona (ES)
Universitat de Barcelona
Openalex Percentile: Top 20%
Coronary Interventions and Diagnostics
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.