Feasibility and efficacy assessment of a novel size-adjustable cryoballoon for ablation of atrial fibrillation in a multicenter clinical setting

Abstract Background The POLARx-FIT cryoballoon (CB) system introduces a unique feature, allowing the selection of two distinct balloon sizes within a single catheter. This innovation holds promise for treating larger pulmonary veins (PV), providing increased flexibility to achieve optimal occlusions. However, there is a scarcity of clinical data supporting its application in this context. Purpose To compare the benefits and safety of the new POLARx-FIT system to those of the existing POLARx system currently in use for PV isolation (PVI) in patients with atrial fibrillation (AF). Methods The first 140 consecutive patients who underwent CB-based PVI with the POLARx-FIT system were retrospectively compared with 300 consecutive patients treated with the POLARx system. Protocol-directed cryoablation was delivered for 180 sec or 240 sec according to operator’s preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation was not available. The ablation endpoint was PVI as assessed by entrance and exit block. In the POLARx-FIT group the choice of balloon size (28 or 31 mm) was determined during the procedure while attempting to occlude each vein. Results Two-thousand one-hundred fifty-five cryo-applications (CBA) from 440 patients were analysed (300, 68.2% POLARx; 140, 31.8% POLARx-FIT). PVI was achieved with cryoablation only in all patients. The mean number of freeze applications per patient was similar between groups (5.0±1.4 in the POLARx-FIT vs 5.3±1.8 in the POLARx group, p=0.207) whereas the number of PVs treated in a single-shot fashion was higher in the POLARx-FIT group (444, 80.7% with one shot; 75, 13.7% with 2 shots; 31, 5.6% with more than 2 shots) than in the POLARx one (1168, 70.2% with one shot, p=0.0002; 294, 17.7% with two shots and 143, 8.6% with more than two shots). Among the POLARx-FIT cases, in 54.2% (n=298) of applications, the 31-mm diameter was employed as a first choice, while in the remaining 45.8% (n=252) of applications, the 28-mm diameter was adopted. A switch to a different balloon diameter was applied in 11.6% of cases. The first pass isolation (i.e. a single shot CBA to achieve PVI) was slightly higher when using a 31 mm diameter (n=250, 83.9%) than a 28 mm diameter (n=194, 77.0%, p=0.05). Three (0.7%) transient phrenic nerve palsy were observed (all in the POLARx group, 0.9%, p=0.554), with full recovery in the 48-h post procedure; no major procedure-related adverse events were reported at 30 days post-procedure. Conclusion In this first multicentric experience in a clinical practice setting, this novel cryo-balloon system proved to be safe and effective and resulted in a high proportion of successful single-freeze isolation. The intraprocedural flexibility of balloon size contributed to its versatility, leading to a variation in balloon diameter in about 12% of freeze applications.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.547
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and efficacy assessment of a novel size-adjustable cryoballoon for ablation of atrial fibrillation in a multicenter clinical setting

Maria Lucia Narducci, Christian B. Albano, M Malacrida, M Schiavone et al.
European Heart Journal
Atrial Fibrillation Management and Outcomes
article

Feasibility and efficacy assessment of a novel size-adjustable cryoballoon for ablation of atrial fibrillation in a multicenter clinical setting

Maria Lucia Narducci, Christian B. Albano, M Malacrida, M Schiavone, Antonio De Simone, M Moltrasio, Gianluigi Bencardino, Claudio Tondo, Domenico Pecora, Stefano Bianchi, Manuel Cerini, Riccardo Ricciolino, Gemma Pelargonio, A Agresta, Antonio Curnis
article en

Abstract

Abstract Background The POLARx-FIT cryoballoon (CB) system introduces a unique feature, allowing the selection of two distinct balloon sizes within a single catheter. This innovation holds promise for treating larger pulmonary veins (PV), providing increased flexibility to achieve optimal occlusions. However, there is a scarcity of clinical data supporting its application in this context. Purpose To compare the benefits and safety of the new POLARx-FIT system to those of the existing POLARx system currently in use for PV isolation (PVI) in patients with atrial fibrillation (AF). Methods The first 140 consecutive patients who underwent CB-based PVI with the POLARx-FIT system were retrospectively compared with 300 consecutive patients treated with the POLARx system. Protocol-directed cryoablation was delivered for 180 sec or 240 sec according to operator’s preference for isolation achieved in ≤60 sec, or 240 sec if isolation occurred >60 sec or when time to isolation was not available. The ablation endpoint was PVI as assessed by entrance and exit block. In the POLARx-FIT group the choice of balloon size (28 or 31 mm) was determined during the procedure while attempting to occlude each vein. Results Two-thousand one-hundred fifty-five cryo-applications (CBA) from 440 patients were analysed (300, 68.2% POLARx; 140, 31.8% POLARx-FIT). PVI was achieved with cryoablation only in all patients. The mean number of freeze applications per patient was similar between groups (5.0±1.4 in the POLARx-FIT vs 5.3±1.8 in the POLARx group, p=0.207) whereas the number of PVs treated in a single-shot fashion was higher in the POLARx-FIT group (444, 80.7% with one shot; 75, 13.7% with 2 shots; 31, 5.6% with more than 2 shots) than in the POLARx one (1168, 70.2% with one shot, p=0.0002; 294, 17.7% with two shots and 143, 8.6% with more than two shots). Among the POLARx-FIT cases, in 54.2% (n=298) of applications, the 31-mm diameter was employed as a first choice, while in the remaining 45.8% (n=252) of applications, the 28-mm diameter was adopted. A switch to a different balloon diameter was applied in 11.6% of cases. The first pass isolation (i.e. a single shot CBA to achieve PVI) was slightly higher when using a 31 mm diameter (n=250, 83.9%) than a 28 mm diameter (n=194, 77.0%, p=0.05). Three (0.7%) transient phrenic nerve palsy were observed (all in the POLARx group, 0.9%, p=0.554), with full recovery in the 48-h post procedure; no major procedure-related adverse events were reported at 30 days post-procedure. Conclusion In this first multicentric experience in a clinical practice setting, this novel cryo-balloon system proved to be safe and effective and resulted in a high proportion of successful single-freeze isolation. The intraprocedural flexibility of balloon size contributed to its versatility, leading to a variation in balloon diameter in about 12% of freeze applications.

European Heart JournalVol. 45(Supplement_1)
Agostino Gemelli University Polyclinic (IT), Centro Cardiologico Monzino (IT), Casa di Cura San Michele (IT), Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (IT), Fatebenefratelli Hospital (IT), Mylan (Switzerland) (CH), Fondazione Poliambulanza Istituto Ospedaliero (IT)
Openalex Percentile: Top 66%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.