Impact on preoperative estimation of atrial mechanical amplitudes with vdd leadless pacemaker

Abstract Background It would be useful to determine whether the device can sense the mechanical atrial amplitude (A4) before the implantation of a VDD leadless pacemaker (Micra AV^RT, Medtronic, US). Purpose To evaluate whether identifiable A4 is associated with preoperative echocardiographic parameters. Methods Echocardiographic measurements were performed to quantify atrial motion of the interventricular septum in patients who received a leadless pacemaker implantation. We visually divided the septum into five segments from the base to the apex. As shown in Figure 1, the myocardial velocity of each segment measured on tissue doppler imaging (TDI) was defined as EV1, EV2, EV3, EV4, and EV5 (m/s), respectively. After the implantation, amplitude of A4 was compared to the local EV. Results We retrospectively analyzed 30 patients who had Micra AV implanted into the right ventricular septum by imaging examination and had measurable EV for each segment. The mean age was 82.3±7.8 years, 15 (50%) patients were female, 11 (37%) patients had organic heart disease, and 23 (77%) patients had atrial ventricular block. The mean LVEF and A4 amplitude were 60.4 ± 8.9% and 2.7 ± 1.8 m/s^2, respectively, and the mean atrial mechanical sensing rate (AMSR) was 79.9±24.0%. The A4 amplitude was positively correlated to the AMSR (r=0.48), while the AMSR was significantly better in patients with A4 amplitude over 1.0 m/s^2 (88.0 ± 10.4% vs. 41.0 ± 33.6%, p=0.04). The A4 amplitude was correlated to the EV of the implantation site estimated from fluoroscopy and echocardiography (r=0.62) in Figure 2. 24 patients had local EV over 3.0 cm/s, and among them, 22 (92%) patients had A4 amplitude over 1.0 m/s^2. Conclusion Local EV over 3.0 cm/s, as determined by preoperative echocardiography, might predict high-frequency AMSR.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.710
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact on preoperative estimation of atrial mechanical amplitudes with vdd leadless pacemaker

Toshinori Chiba, Yoshinobu Komai, Yutaka Yoshino, Satoko Ryuzaki et al.
European Heart Journal
Cardiovascular Function and Risk Factors
article

Impact on preoperative estimation of atrial mechanical amplitudes with vdd leadless pacemaker

Toshinori Chiba, Yoshinobu Komai, Yutaka Yoshino, Satoko Ryuzaki, Yukiko Takanashi, Takatsugu Kajiyama, Makiko Nakano, Ryo Ito, Yusuke Kondo, Yohei Kobayashi
article en

Abstract

Abstract Background It would be useful to determine whether the device can sense the mechanical atrial amplitude (A4) before the implantation of a VDD leadless pacemaker (Micra AV^RT, Medtronic, US). Purpose To evaluate whether identifiable A4 is associated with preoperative echocardiographic parameters. Methods Echocardiographic measurements were performed to quantify atrial motion of the interventricular septum in patients who received a leadless pacemaker implantation. We visually divided the septum into five segments from the base to the apex. As shown in Figure 1, the myocardial velocity of each segment measured on tissue doppler imaging (TDI) was defined as EV1, EV2, EV3, EV4, and EV5 (m/s), respectively. After the implantation, amplitude of A4 was compared to the local EV. Results We retrospectively analyzed 30 patients who had Micra AV implanted into the right ventricular septum by imaging examination and had measurable EV for each segment. The mean age was 82.3±7.8 years, 15 (50%) patients were female, 11 (37%) patients had organic heart disease, and 23 (77%) patients had atrial ventricular block. The mean LVEF and A4 amplitude were 60.4 ± 8.9% and 2.7 ± 1.8 m/s^2, respectively, and the mean atrial mechanical sensing rate (AMSR) was 79.9±24.0%. The A4 amplitude was positively correlated to the AMSR (r=0.48), while the AMSR was significantly better in patients with A4 amplitude over 1.0 m/s^2 (88.0 ± 10.4% vs. 41.0 ± 33.6%, p=0.04). The A4 amplitude was correlated to the EV of the implantation site estimated from fluoroscopy and echocardiography (r=0.62) in Figure 2. 24 patients had local EV over 3.0 cm/s, and among them, 22 (92%) patients had A4 amplitude over 1.0 m/s^2. Conclusion Local EV over 3.0 cm/s, as determined by preoperative echocardiography, might predict high-frequency AMSR.

European Heart JournalVol. 45(Supplement_1)
Chiba University (JP)
Openalex Percentile: Top 66%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.