Cuff-less wearable biosensor in continuous noninvasive human radial artery pulse waveform and blood pressure measurement using self-mixing interferometry

In this paper, we propose a compact, wearable biosensor for the noninvasive measurement of human radial artery pulse waveform curve (PWC) and blood pressure (BP). In this system, self-mixing interferometry (SMI) technology is employed to measure the weak arterial vascular deformation, enabling accurate PWC retrieval. Based on the reconstructed PWC features, BP values are precisely estimated by means of deep learning method. Here continuous wavelet transform (CWT), enabling visualization of the relationship between the SMI signal temporal frequency components and the PWC characteristics, is highlighted for PWC flipping points seeking and convolutional neural network (CNN) input parameter acquisition. For the first time, a novel deep learning network preprocessing method is proposed that allows direct feature extraction from the CWT scalogram of SMI signal without the complicated PWC reconstruction algorithm. The robustness and accuracy of our device are validated by a series of clinical measurements, mean absolute error (MAE) and standard deviation (STD) values are calculated and compared with the existing models. We approach minimal BP estimation results (MAE ± STD) of 1.41 ± 1.89 mmHg for systolic blood pressure (SBP) and 1.78 ± 2.01 mmHg for diastolic blood pressure (DBP), respectively. The luxuriant novelties and remarkable performance clearly demonstrate our wearable sensor’s great potential in BP monitoring, and other clinical applications.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-10-28
DOI
https://doi.org/10.1364/oe.534566
Citations
4
Primary Topic
Semiconductor Lasers and Optical Devices
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cuff-less wearable biosensor in continuous noninvasive human radial artery pulse waveform and blood pressure measurement using self-mixing interferometry

Jian Hu, Zihua Zhang, Tao Chen, Yu Zhao et al.
4 citations
Optics Express
Semiconductor Lasers and Optical Devices
0.83
article

Cuff-less wearable biosensor in continuous noninvasive human radial artery pulse waveform and blood pressure measurement using self-mixing interferometry

Jian Hu, Zihua Zhang, Tao Chen, Yu Zhao, Xiaobo Yao
article en
4 citations

Abstract

In this paper, we propose a compact, wearable biosensor for the noninvasive measurement of human radial artery pulse waveform curve (PWC) and blood pressure (BP). In this system, self-mixing interferometry (SMI) technology is employed to measure the weak arterial vascular deformation, enabling accurate PWC retrieval. Based on the reconstructed PWC features, BP values are precisely estimated by means of deep learning method. Here continuous wavelet transform (CWT), enabling visualization of the relationship between the SMI signal temporal frequency components and the PWC characteristics, is highlighted for PWC flipping points seeking and convolutional neural network (CNN) input parameter acquisition. For the first time, a novel deep learning network preprocessing method is proposed that allows direct feature extraction from the CWT scalogram of SMI signal without the complicated PWC reconstruction algorithm. The robustness and accuracy of our device are validated by a series of clinical measurements, mean absolute error (MAE) and standard deviation (STD) values are calculated and compared with the existing models. We approach minimal BP estimation results (MAE ± STD) of 1.41 ± 1.89 mmHg for systolic blood pressure (SBP) and 1.78 ± 2.01 mmHg for diastolic blood pressure (DBP), respectively. The luxuriant novelties and remarkable performance clearly demonstrate our wearable sensor’s great potential in BP monitoring, and other clinical applications.

Optics ExpressVol. 32(24)
Beijing University of Technology (CN)
National Natural Science Foundation of China
Zero hunger
Openalex Percentile: Top 26%
Semiconductor Lasers and Optical Devices
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.