Impact of Cavity Length Non-uniformity on Reaction Rate Extraction in Strong Coupling Experiments

Reports of altered chemical phenomena under vibrational strong coupling, including reaction rates, product distributions, intermolecular forces, and cavity-mediated vibrational energy transfer, have been met with a great deal of skepticism due to several irreproducible results and the lack of an accepted theoretical framework. In this work, we add some insight by identifying a UV-vis measurement artifact that distorts observed absorption peak positions, amplitudes, and consequently, chemical reaction rates extracted in optical microcavities. We predict and characterize the behavior of this artifact using the Transfer Matrix (TM) method and confirm its presence experimentally. We then present a correction technique whereby an effective molar absorption coefficient is assigned to an absorbing species within the cavity. These revelations have important implications for many existing examples of cavity-modified chemistry and establishing best practices for carrying out robust future investigations.

Authors

Institutions

Publication Details

Journal
Journal of the American Chemical Society
Published
2024-10-28
DOI
https://doi.org/10.1021/jacs.4c12269
Citations
20
Primary Topic
Strong Light-Matter Interactions
Type
article
Field-Weighted Citation Impact
6.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Cavity Length Non-uniformity on Reaction Rate Extraction in Strong Coupling Experiments

Michael A. Michon, Blake S. Simpkins
20 citations
Journal of the American Chemical Society
Strong Light-Matter Interactions
6.75
article

Impact of Cavity Length Non-uniformity on Reaction Rate Extraction in Strong Coupling Experiments

Michael A. Michon, Blake S. Simpkins
article en
20 citations

Abstract

Reports of altered chemical phenomena under vibrational strong coupling, including reaction rates, product distributions, intermolecular forces, and cavity-mediated vibrational energy transfer, have been met with a great deal of skepticism due to several irreproducible results and the lack of an accepted theoretical framework. In this work, we add some insight by identifying a UV-vis measurement artifact that distorts observed absorption peak positions, amplitudes, and consequently, chemical reaction rates extracted in optical microcavities. We predict and characterize the behavior of this artifact using the Transfer Matrix (TM) method and confirm its presence experimentally. We then present a correction technique whereby an effective molar absorption coefficient is assigned to an absorbing species within the cavity. These revelations have important implications for many existing examples of cavity-modified chemistry and establishing best practices for carrying out robust future investigations.

Journal of the American Chemical SocietyVol. 146(44)
Naval Research Laboratory Chemistry Division
Openalex Percentile: Top 2%
Strong Light-Matter Interactions
6.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.