Comparing cerebral microembolisation patterns between high power short duration and pulsed field ablation techniques using artificial intelligence based robotic transcranial doppler monitoring

Abstract Thromboembolism is a rare (<1%) complication of atrial fibrillation (AF) ablation , but the incidence of silent ischaemic lesions (SIL) is 5-15% (1). Artificial intelligence (AI)-based robotic transcranial Doppler (r-TCD) enables real-time cerebral embolisation detection. We aimed to investigate the cerebral microembolization signal (MES) load with r-TCD of patients undergoing PF ablation, comparing the number of detected MES-s between 90 W radiofrequency (RFA) "very high power short duration (vHPSD) ablation" and "pulsed field ablation (PFA)" techniques. Our interim analysis included r-TCD registratums of 26 patients. 16 interventions were performed with VHPSD, 10 with PFA, during which we recorded the flow curve of the arteria cerebri media (ACM) bilaterally with r-TCD and analyzed the MES-s quantitatively and qualitatively with AI-based embolisation detection software. Postoperative cranial MRI exams were performed. Continuous variables were compared between the groups using a two-sample t-test, and categorical variables were compared using a Fisher exact test. The MES load by the different pulmonary veins was compared using Wilcoxon test and Bonferroni correction. A p-value below 0,05 was considered significant. The two groups were comparable regarding baseline parameters (mean age: 63 vs.58 p=0,253; EF:59% vs.62 .2% p=0,33). Ablations with vHPSD were significantly longer compared to PFA (88,7 min vs. 54,7 min p<0,001), left atrial time was significantly shorter with PFA (52,1 min vs. 29 min p<0 001), but the fluoroscopic time was significantly longer (5,4 min vs. 9,3 min p=0,009) during ablation with PFA. Neither solid emboli, nor ischaemic lesion or neurological deficit was detected. During the ablations, we saw an average of 246 gas MES-s with PFA and 138 with RFA (p=0,216). During PFA we analyzed the MES load per pulmonary vein: by the left superior vein we detected a median of 56,5 (IQR: 21,5-116,5), by the left inferior there were a median of 23 MES-s (IQR: 4,5 115,5), by the right inferior a median of 32 (IQR: 12-84,5), and by the right superior a median of 22,5(IQR: 8,5-70) respectively, p=0,03. While comparing each veins to each other, by the right vs. left superior vein, the p value resulted 0,01. On an initial sample,we detected known differences in the procedural parameters of the two interventions. There tended to be more MES-s during PFA, but this difference was not significant. Regarding the MES load by the ablation of different pulmonary veins, we found a significant overall difference between the MES load by the four veins, especially between the left and right superior vein. A larger number of interventions and r-TCD registratums is needed to determine the cerebral safety of PFA compared to RFA.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.384
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing cerebral microembolisation patterns between high power short duration and pulsed field ablation techniques using artificial intelligence based robotic transcranial doppler monitoring

Péter Vámosi, Henriette Mészáros, Nándor Szegedi, László Gellér et al.
1 citations
European Heart Journal
Medical Imaging Techniques and Applications
0.40
article

Comparing cerebral microembolisation patterns between high power short duration and pulsed field ablation techniques using artificial intelligence based robotic transcranial doppler monitoring

Péter Vámosi, Henriette Mészáros, Nándor Szegedi, László Gellér, Klaudia Vivien Nagy, F Komlosi, Péter Tóth, Zoltán Salló, Sándor Nardai, Pál Perge, Zs. Simon
article en
1 citations

Abstract

Abstract Thromboembolism is a rare (<1%) complication of atrial fibrillation (AF) ablation , but the incidence of silent ischaemic lesions (SIL) is 5-15% (1). Artificial intelligence (AI)-based robotic transcranial Doppler (r-TCD) enables real-time cerebral embolisation detection. We aimed to investigate the cerebral microembolization signal (MES) load with r-TCD of patients undergoing PF ablation, comparing the number of detected MES-s between 90 W radiofrequency (RFA) "very high power short duration (vHPSD) ablation" and "pulsed field ablation (PFA)" techniques. Our interim analysis included r-TCD registratums of 26 patients. 16 interventions were performed with VHPSD, 10 with PFA, during which we recorded the flow curve of the arteria cerebri media (ACM) bilaterally with r-TCD and analyzed the MES-s quantitatively and qualitatively with AI-based embolisation detection software. Postoperative cranial MRI exams were performed. Continuous variables were compared between the groups using a two-sample t-test, and categorical variables were compared using a Fisher exact test. The MES load by the different pulmonary veins was compared using Wilcoxon test and Bonferroni correction. A p-value below 0,05 was considered significant. The two groups were comparable regarding baseline parameters (mean age: 63 vs.58 p=0,253; EF:59% vs.62 .2% p=0,33). Ablations with vHPSD were significantly longer compared to PFA (88,7 min vs. 54,7 min p<0,001), left atrial time was significantly shorter with PFA (52,1 min vs. 29 min p<0 001), but the fluoroscopic time was significantly longer (5,4 min vs. 9,3 min p=0,009) during ablation with PFA. Neither solid emboli, nor ischaemic lesion or neurological deficit was detected. During the ablations, we saw an average of 246 gas MES-s with PFA and 138 with RFA (p=0,216). During PFA we analyzed the MES load per pulmonary vein: by the left superior vein we detected a median of 56,5 (IQR: 21,5-116,5), by the left inferior there were a median of 23 MES-s (IQR: 4,5 115,5), by the right inferior a median of 32 (IQR: 12-84,5), and by the right superior a median of 22,5(IQR: 8,5-70) respectively, p=0,03. While comparing each veins to each other, by the right vs. left superior vein, the p value resulted 0,01. On an initial sample,we detected known differences in the procedural parameters of the two interventions. There tended to be more MES-s during PFA, but this difference was not significant. Regarding the MES load by the ablation of different pulmonary veins, we found a significant overall difference between the MES load by the four veins, especially between the left and right superior vein. A larger number of interventions and r-TCD registratums is needed to determine the cerebral safety of PFA compared to RFA.

European Heart JournalVol. 45(Supplement_1)
Semmelweis University (HU), National Institute of Mental Health (JP)
Openalex Percentile: Top 33%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.