Surgical reduction of a high-flow dialysis fistula has long-term positive effects of the heart

Abstract Introduction Part of chronic haemodialysis patients develop a high-flow arteriovenous fistula (AVF). The volume overload caused by the presence of a high-flow AVF leads to increased cardiac output, dilation of cardiac chambers, increased pulmonary artery pressure or even to the development of high-output heart failure. Our previous data showed a positive effect of AVF flow-reducing surgery in 6 weeks follow-up. Purpose The purpose of this study was to analyse the long-term effect of AVF blood flow (Qa) reduction on cardiac structure and function. Methods We included patients with high-flow AVFs (defined as Qa over 1500 mL/min) indicated for blood flow reduction surgery for heart failure symptoms or pre-defined echocardiographic changes (left ventricular hypertrophy, severe secondary valvular regurgitations, or pulmonary hypertension). Echocardiography was performed one day before the surgery, the 6 weeks, 6 months, and 12 months thereafter. Qa was measured by ultrasound during the same visits. Results 27 patients were included, 20 men and 7 women, aged 57 ± 13 years. The procedure led to an immediate decrease in Qa. However, we observed failure of the procedure within 1 year in 8 (= 30%) patients defined by increased Qa back to pre-surgery values. Detailed results are displayed in Table 1. Estimated pulmonary arterial systolic pressure and left atrial volume remained significantly lower after 1 year despite the Qa rise. Effective cardiac output (= difference of cardiac output and Qa) rose immediately and remained increased during the follow-up period despite the increase in AVF blood flow. Conclusions We observed a long-time positive effect of AVF blood flow reduction surgery on the heart despite a significant Qa rise. The effective cardiac output remained increased despite the gradual increase of Qa, probably due to the adaptation of systemic arterioles.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.3273
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Surgical reduction of a high-flow dialysis fistula has long-term positive effects of the heart

Anna Valeriánová, Jan Malík, Kristína Burýšková Salajová
European Heart Journal
Central Venous Catheters and Hemodialysis
article

Surgical reduction of a high-flow dialysis fistula has long-term positive effects of the heart

Anna Valeriánová, Jan Malík, Kristína Burýšková Salajová
article en

Abstract

Abstract Introduction Part of chronic haemodialysis patients develop a high-flow arteriovenous fistula (AVF). The volume overload caused by the presence of a high-flow AVF leads to increased cardiac output, dilation of cardiac chambers, increased pulmonary artery pressure or even to the development of high-output heart failure. Our previous data showed a positive effect of AVF flow-reducing surgery in 6 weeks follow-up. Purpose The purpose of this study was to analyse the long-term effect of AVF blood flow (Qa) reduction on cardiac structure and function. Methods We included patients with high-flow AVFs (defined as Qa over 1500 mL/min) indicated for blood flow reduction surgery for heart failure symptoms or pre-defined echocardiographic changes (left ventricular hypertrophy, severe secondary valvular regurgitations, or pulmonary hypertension). Echocardiography was performed one day before the surgery, the 6 weeks, 6 months, and 12 months thereafter. Qa was measured by ultrasound during the same visits. Results 27 patients were included, 20 men and 7 women, aged 57 ± 13 years. The procedure led to an immediate decrease in Qa. However, we observed failure of the procedure within 1 year in 8 (= 30%) patients defined by increased Qa back to pre-surgery values. Detailed results are displayed in Table 1. Estimated pulmonary arterial systolic pressure and left atrial volume remained significantly lower after 1 year despite the Qa rise. Effective cardiac output (= difference of cardiac output and Qa) rose immediately and remained increased during the follow-up period despite the increase in AVF blood flow. Conclusions We observed a long-time positive effect of AVF blood flow reduction surgery on the heart despite a significant Qa rise. The effective cardiac output remained increased despite the gradual increase of Qa, probably due to the adaptation of systemic arterioles.

European Heart JournalVol. 45(Supplement_1)
General University Hospital in Prague (CZ)
Všeobecná Fakultní Nemocnice v Praze
Openalex Percentile: Top 67%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Surgical reduction of a high-flow dialysis fistula has long-term positive effects of the heart — Anna Valeriánová, Jan Malík, et al. · European Heart Journal (2024) | TGRS Research Map | TGRS