Artificial intelligence-enhanced electrocardiography predicts 10-year risk of atherosclerotic cardiovascular disease

Abstract Background The ACC/AHA pooled cohort equations (PCE) calculates the 10-year primary risk of atherosclerotic cardiovascular disease (ASCVD), an indication to initiate primary prevention statin therapy in international guidelines. The validity of PCE is limited by its overestimation of risk in high-risk cohorts and an ethnic heterogeneity. Electrocardiography (ECG) has not been incorporated in current ASCVD risk estimation tools. Artificial Intelligence (AI)-based models are capable to capture patterns that are informative for cardiovascular prognosis. Purpose We explored the predictive value of a discrete-time survival model in 10-year ASCVD risk in comparison to PCE. Methods We developed an AI-ECG model to predict the 10-year ASCVD risk in an unselected secondary care population from the USA comprised of 1,163,401 ECGs from 189,539 patients. Data was split into training/validation and hold-out test sets by patient ID. Our AI-ECG model uses deep learning with a residual convolutional neural network with a discrete-time survival loss function to output subject-specific survival curves, accounting for both time to event and censorship (i.e., loss to follow up). We compared the performance of out AI-ECG model using a subset of outpatient data (n=4590) of the BIDMC dataset to PCE and ASCVD risk factors including systolic blood pressure, total cholesterol, HDL cholesterol, hypertension, smoking history, diabetes mellitus, and ethnicity. Performances were evaluated using cox survival analysis. Our AI-ECG model was externally validated in the UKB Biobank (UKB), where we compared the performance of our AI-ECG model to predictions of existing AI-ECG models such as the Stanford Estimator of Electrocardiogram Risk (SEER) model. Results Our AI-ECG successfully predicted future ASCVD events in individuals (C-index 0.721 (0.719-0.723), 5-year AUC 0.761 (0.758-0.763), and differentiated between high and low risk group with an adjusted HR of 2.33 (2.26-2.41). Upon internal validation our AI-ECG model showed a superior performance (C-index 0.679 (0.651-0.708)) than PCE (0.605 (0.577-0.634)) and all risk factors combined (C index 0.642 (0.613-0.672)). When combining AI-ECG predictions with all risk factors, the model showed additional predictive value (0.686 (0.657-0.715)) (Figure 1). Our AI-ECG model showed modest predictive value within the UKB dataset (C-index 0.655 (0.637-0.673)), but significantly outperformed the SEER model (C-index 0.547 (0.527-0.567), p <0.0001 for comparison with AIRE). Conclusion We have shown the potential of AI-ECG models in predicting future ASCVD risks. AI-ECG models demonstrated accurate discrete time survival prediction and good classification performance superior to that of the SEER model, as well as PCE and ASCVD risk factors. . Accurate risk assessment of ASCVD may help prevent adverse events in high risk subjects and save unnecessary pharmacological interventios in low risk subjects.Figure 1

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.3499
Citations
1
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence-enhanced electrocardiography predicts 10-year risk of atherosclerotic cardiovascular disease

Yixiu Liang, Joseph Barker, Konstantinos Patlatzoglou, Libor Pastika et al.
1 citations
European Heart Journal
Cardiovascular Disease and Adiposity
0.40
article

Artificial intelligence-enhanced electrocardiography predicts 10-year risk of atherosclerotic cardiovascular disease

Yixiu Liang, Joseph Barker, Konstantinos Patlatzoglou, Libor Pastika, Ewa Sieliwończyk, Daniel B. Kramer, Arunashis Sau, Fu Siong Ng, Jonathan W. Waks, H Zhang, Mehak Gurnani, Boroumand Zeidaabadi, Krzysztof Macierzanka, Nils Peters
article en
1 citations

Abstract

Abstract Background The ACC/AHA pooled cohort equations (PCE) calculates the 10-year primary risk of atherosclerotic cardiovascular disease (ASCVD), an indication to initiate primary prevention statin therapy in international guidelines. The validity of PCE is limited by its overestimation of risk in high-risk cohorts and an ethnic heterogeneity. Electrocardiography (ECG) has not been incorporated in current ASCVD risk estimation tools. Artificial Intelligence (AI)-based models are capable to capture patterns that are informative for cardiovascular prognosis. Purpose We explored the predictive value of a discrete-time survival model in 10-year ASCVD risk in comparison to PCE. Methods We developed an AI-ECG model to predict the 10-year ASCVD risk in an unselected secondary care population from the USA comprised of 1,163,401 ECGs from 189,539 patients. Data was split into training/validation and hold-out test sets by patient ID. Our AI-ECG model uses deep learning with a residual convolutional neural network with a discrete-time survival loss function to output subject-specific survival curves, accounting for both time to event and censorship (i.e., loss to follow up). We compared the performance of out AI-ECG model using a subset of outpatient data (n=4590) of the BIDMC dataset to PCE and ASCVD risk factors including systolic blood pressure, total cholesterol, HDL cholesterol, hypertension, smoking history, diabetes mellitus, and ethnicity. Performances were evaluated using cox survival analysis. Our AI-ECG model was externally validated in the UKB Biobank (UKB), where we compared the performance of our AI-ECG model to predictions of existing AI-ECG models such as the Stanford Estimator of Electrocardiogram Risk (SEER) model. Results Our AI-ECG successfully predicted future ASCVD events in individuals (C-index 0.721 (0.719-0.723), 5-year AUC 0.761 (0.758-0.763), and differentiated between high and low risk group with an adjusted HR of 2.33 (2.26-2.41). Upon internal validation our AI-ECG model showed a superior performance (C-index 0.679 (0.651-0.708)) than PCE (0.605 (0.577-0.634)) and all risk factors combined (C index 0.642 (0.613-0.672)). When combining AI-ECG predictions with all risk factors, the model showed additional predictive value (0.686 (0.657-0.715)) (Figure 1). Our AI-ECG model showed modest predictive value within the UKB dataset (C-index 0.655 (0.637-0.673)), but significantly outperformed the SEER model (C-index 0.547 (0.527-0.567), p <0.0001 for comparison with AIRE). Conclusion We have shown the potential of AI-ECG models in predicting future ASCVD risks. AI-ECG models demonstrated accurate discrete time survival prediction and good classification performance superior to that of the SEER model, as well as PCE and ASCVD risk factors. . Accurate risk assessment of ASCVD may help prevent adverse events in high risk subjects and save unnecessary pharmacological interventios in low risk subjects.Figure 1

European Heart JournalVol. 45(Supplement_1)
Beth Israel Deaconess Medical Center (US), Lung Institute (US), Imperial College London (GB)
Openalex Percentile: Top 31%
Cardiovascular Disease and Adiposity
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.