The optimal cut-off value for the one-minute sit-to-stand test to determine functional impairment in patients with pulmonary hypertension

Abstract Introduction Pulmonary hypertension (PH) often leads to reduced functional capacity, commonly assessed by the six-minute walk test (6MWT). The 1-min sit-to-stand test (1-min STST) is a shorter test with smaller space requirements. Despite its potential utility, to our knowledge no studies have determined the optimal cut-off value for the 1-min STST in patients with PH. Aim This study aimed to assess the optimal cut-off value for the 1-min STST by utilizing three established 6MWT thresholds (165m, 320m, and 440m) recommended in current European PH guidelines published by Humbert et al. (1). Methods A receiver operating characteristics (ROC) curve analysis was conducted to identify a threshold for the 1-min STST, aligning with the three 6MWT cut-offs. Clinical parameters and health-related quality of life (HRQoL) assessed through the Cambridge Pulmonary Hypertension Outcome Review (CAMPHOR) questionnaire were evaluated. Results A total number of 114 patients with PH (mean age 66±14 years, 57% female) were included in the analysis. Patients performed a mean number of 17±7 repetitions in the 1-min STST and achieved a mean 6MWT distance of 351±137m. The <165m 6MWT threshold revealed the highest area under the curve (AUC=0.90; 95%-CI 0.84-0.97). The optimal cut-off for the 1-min STST was 14.5 repetitions, exhibiting 69% sensitivity and 100% specificity. Patients below this threshold demonstrated significantly worse clinical parameters and reported worse HRQoL (p<0.001), as shown in Table 1. Conclusion A 1-min STST cut-off of 14.5 repetitions identified PH patients with functional impairment, suggesting its potential utility for risk stratification.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2965
Primary Topic
Pulmonary Hypertension Research and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The optimal cut-off value for the one-minute sit-to-stand test to determine functional impairment in patients with pulmonary hypertension

Christoph Krall, Nikita Ermolaev, Roza Badr Eslam, Robin Willixhofer et al.
European Heart Journal
Pulmonary Hypertension Research and Treatments
article

The optimal cut-off value for the one-minute sit-to-stand test to determine functional impairment in patients with pulmonary hypertension

Christoph Krall, Nikita Ermolaev, Roza Badr Eslam, Robin Willixhofer, Brigitte Litschauer, Nima Rassoulpour, Michael Poledniczek, Christina Kronberger, Musa Kaya
article en

Abstract

Abstract Introduction Pulmonary hypertension (PH) often leads to reduced functional capacity, commonly assessed by the six-minute walk test (6MWT). The 1-min sit-to-stand test (1-min STST) is a shorter test with smaller space requirements. Despite its potential utility, to our knowledge no studies have determined the optimal cut-off value for the 1-min STST in patients with PH. Aim This study aimed to assess the optimal cut-off value for the 1-min STST by utilizing three established 6MWT thresholds (165m, 320m, and 440m) recommended in current European PH guidelines published by Humbert et al. (1). Methods A receiver operating characteristics (ROC) curve analysis was conducted to identify a threshold for the 1-min STST, aligning with the three 6MWT cut-offs. Clinical parameters and health-related quality of life (HRQoL) assessed through the Cambridge Pulmonary Hypertension Outcome Review (CAMPHOR) questionnaire were evaluated. Results A total number of 114 patients with PH (mean age 66±14 years, 57% female) were included in the analysis. Patients performed a mean number of 17±7 repetitions in the 1-min STST and achieved a mean 6MWT distance of 351±137m. The <165m 6MWT threshold revealed the highest area under the curve (AUC=0.90; 95%-CI 0.84-0.97). The optimal cut-off for the 1-min STST was 14.5 repetitions, exhibiting 69% sensitivity and 100% specificity. Patients below this threshold demonstrated significantly worse clinical parameters and reported worse HRQoL (p<0.001), as shown in Table 1. Conclusion A 1-min STST cut-off of 14.5 repetitions identified PH patients with functional impairment, suggesting its potential utility for risk stratification.

European Heart JournalVol. 45(Supplement_1)
Medical University of Vienna (AT)
Openalex Percentile: Top 65%
Pulmonary Hypertension Research and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.