Comparison of ICD implantation approach in children. The IChilDren study

Abstract Background Without dedicated device, implantable cardioverter defibrillators (ICD) implantation in children is a real challenge for physicians. Types of implantation include transvenous, surgical and subcutaneous-ICD approach, but with a lack of reliable data comparing their respective efficacy and safety. Objective We here aim to compare the results of these 3 ICD implantation approaches in children. Methods Consecutive children (<16yo) implanted with an ICD from 2005 to 2021 in 19 french tertiary centers of the French Pediatric and Congenital heart disease network, were retrospectively enrolled in the study. The primary endpoints were the occurrence of lead failure, device infection or inappropriate shock. Results Among 306 patients (mean age 12,6 yo), 34% received a transvenous ICD, 28% a S-ICD and 38% a surgical ICD. During a median follow-up of 4.7 years, endpoints occurred in 24.2% of the total population, more often in the surgical group (p<0.05). After adjustment for age, ICD type and stratification by heart disease, there was an excess risk of lead failure or infection with the surgical ICD compared with the S-ICD (HR 7.54, 95% CI 1.73;32.91, p<0.05). However, when inappropriate shocks were included, the difference was reduced (HR 2.28, 95% CI 1.03;5.04, p>0.05). In addition, no significant difference between transvenous and surgical ICDs was observed in the multivariate analysis. Conclusions We demonstrate a high rate of complication in children implanted with an ICD. The transvenous and surgical approaches are quite similar. S-ICD appears as a promising approach with the lowest serious adverse event rate. Limitation of inappropriate shock remain the main challenge of this technique.Late complications

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.367
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of ICD implantation approach in children. The IChilDren study

Jean‐Baptiste Gourraud, Linda Koutbi, Alice Maltret, Victor Waldmann et al.
European Heart Journal
Cardiac pacing and defibrillation studies
article

Comparison of ICD implantation approach in children. The IChilDren study

Jean‐Baptiste Gourraud, Linda Koutbi, Alice Maltret, Victor Waldmann, Hugues Blangy, Rui Martins, Pierre Bordachar, Pascal Amédro, Vanessa Suziane Probst, Philippe Maury, Aurélien Clédel, Laurence Jesel, Christelle Marquié
article en

Abstract

Abstract Background Without dedicated device, implantable cardioverter defibrillators (ICD) implantation in children is a real challenge for physicians. Types of implantation include transvenous, surgical and subcutaneous-ICD approach, but with a lack of reliable data comparing their respective efficacy and safety. Objective We here aim to compare the results of these 3 ICD implantation approaches in children. Methods Consecutive children (<16yo) implanted with an ICD from 2005 to 2021 in 19 french tertiary centers of the French Pediatric and Congenital heart disease network, were retrospectively enrolled in the study. The primary endpoints were the occurrence of lead failure, device infection or inappropriate shock. Results Among 306 patients (mean age 12,6 yo), 34% received a transvenous ICD, 28% a S-ICD and 38% a surgical ICD. During a median follow-up of 4.7 years, endpoints occurred in 24.2% of the total population, more often in the surgical group (p<0.05). After adjustment for age, ICD type and stratification by heart disease, there was an excess risk of lead failure or infection with the surgical ICD compared with the S-ICD (HR 7.54, 95% CI 1.73;32.91, p<0.05). However, when inappropriate shocks were included, the difference was reduced (HR 2.28, 95% CI 1.03;5.04, p>0.05). In addition, no significant difference between transvenous and surgical ICDs was observed in the multivariate analysis. Conclusions We demonstrate a high rate of complication in children implanted with an ICD. The transvenous and surgical approaches are quite similar. S-ICD appears as a promising approach with the lowest serious adverse event rate. Limitation of inappropriate shock remain the main challenge of this technique.Late complications

European Heart JournalVol. 45(Supplement_1)
Hôpital Necker-Enfants Malades (FR), Université de Lille (FR), Centre Hospitalier Régional et Universitaire de Nancy (FR), Hôpital Marie Lannelongue (FR), Hôpital Pontchaillou (FR), Hôpital Arnaud de Villeneuve (FR), Hôpital de la Timone (FR), Université de Strasbourg (FR)
Openalex Percentile: Top 66%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.