The evolution of endothelial dysfunction according to the length of the implanted stent on the background of nebivolol therapy

Abstract Introduction The development of atherosclerosis is the driving cause for arterial interventions using coronary stents. Long-stent implantation can increase the vascular injury thereby contributing to the progression of endothelial dysfunction (ED) by the degradation and reduction bioavailability of the nitric oxide (NO) - thus increasing the risk of major cardiovascular events. Purpose Evaluation the evolution of endothelial dysfunction biomarker depending on the length of the stent implanted on the background of nebivolol therapy. Methods The study included 100 patients with stable angina pectoris II–III functional class (age 59.72±0.59 years) undergoing PCI with stent implantation who started the treatment with nebivolol 5mg per day tangent to the conventional treatment and were exposed to PCI with stent implantation, depending on the stent’s length they were divided in three groups: I group - 14 patients with implanted stent’s length ≤15 mm, II group - 57 subjects with implanted stent’s length =15-30 mm and the III group -29 cases where the implanted stent’s length was ≥30 mm. In all the groups was appreciated in blood the endothelial dysfunction’s marker - NO. This marker was assessed preprocedural, postprocedural (after 24 hours) and at intervals of one month, 3,6,12 months after coronary angioplasty, the NO level being compared between these groups and the reference pattern consisting of 20 healthy people. Results The circulating level of nitric oxide determined in I group -61,28±6,92 μM/L and in the II group -56.6±3.03 μM/L and the III group52.39±3.35 was compromised at the preprocedural stage versus the reference pattern - 78.67±2.72 μM/L. During the post- PCI period (first 24 hours), the biomarker level’s was reduced in I group -52.35±1.66 μM/ L, II group -53.74±2.77 μM/L and III group - 52.98±2.91 μM/L. After one month after the intervention on the backroung of the treatment with nebivolol, was recorded a gaing of the NO value in I group - 64.97±5.35 μM/L, II group -63.15±3.99 μM /L and the III group-59.38±4.46 μM/L. The NO serum concentration during the period 3 and 6 months continued to increase in all groups vs the reference pattern. At the 12-month period, the NO level remained high in all the studied groups versus the baseline: I group 99.2±1.1 μM / L (p>0.05), II group-97.96±2.2 μM/L (p<0.001) and the III group -97.65±1.9 μM/L (p<0.001). Conclusion The stent’s length = 15-30 mm and ≥30 mm reveals the presence of an expanded atherosclerotic process, the substrate of which is constituted by the endothelial dysfunction, this being confirmed by the low preprocedural level of NO. The stent implantation procedure induced the accentuation of endothelial dysfunction, and the 12-month nebivolol treatment favored the increase of NO serum concentraon in all groups by 24.9% vs the reference pattern and by 73.3% vs baseline.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2375
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The evolution of endothelial dysfunction according to the length of the implanted stent on the background of nebivolol therapy

L. Simionov, В. М. Иванов, Alexandr Ceasovschih, Dumanschi Carolina et al.
European Heart Journal
Cardiovascular Health and Disease Prevention
article

The evolution of endothelial dysfunction according to the length of the implanted stent on the background of nebivolol therapy

L. Simionov, В. М. Иванов, Alexandr Ceasovschih, Dumanschi Carolina, V Dolghi
article en

Abstract

Abstract Introduction The development of atherosclerosis is the driving cause for arterial interventions using coronary stents. Long-stent implantation can increase the vascular injury thereby contributing to the progression of endothelial dysfunction (ED) by the degradation and reduction bioavailability of the nitric oxide (NO) - thus increasing the risk of major cardiovascular events. Purpose Evaluation the evolution of endothelial dysfunction biomarker depending on the length of the stent implanted on the background of nebivolol therapy. Methods The study included 100 patients with stable angina pectoris II–III functional class (age 59.72±0.59 years) undergoing PCI with stent implantation who started the treatment with nebivolol 5mg per day tangent to the conventional treatment and were exposed to PCI with stent implantation, depending on the stent’s length they were divided in three groups: I group - 14 patients with implanted stent’s length ≤15 mm, II group - 57 subjects with implanted stent’s length =15-30 mm and the III group -29 cases where the implanted stent’s length was ≥30 mm. In all the groups was appreciated in blood the endothelial dysfunction’s marker - NO. This marker was assessed preprocedural, postprocedural (after 24 hours) and at intervals of one month, 3,6,12 months after coronary angioplasty, the NO level being compared between these groups and the reference pattern consisting of 20 healthy people. Results The circulating level of nitric oxide determined in I group -61,28±6,92 μM/L and in the II group -56.6±3.03 μM/L and the III group52.39±3.35 was compromised at the preprocedural stage versus the reference pattern - 78.67±2.72 μM/L. During the post- PCI period (first 24 hours), the biomarker level’s was reduced in I group -52.35±1.66 μM/ L, II group -53.74±2.77 μM/L and III group - 52.98±2.91 μM/L. After one month after the intervention on the backroung of the treatment with nebivolol, was recorded a gaing of the NO value in I group - 64.97±5.35 μM/L, II group -63.15±3.99 μM /L and the III group-59.38±4.46 μM/L. The NO serum concentration during the period 3 and 6 months continued to increase in all groups vs the reference pattern. At the 12-month period, the NO level remained high in all the studied groups versus the baseline: I group 99.2±1.1 μM / L (p>0.05), II group-97.96±2.2 μM/L (p<0.001) and the III group -97.65±1.9 μM/L (p<0.001). Conclusion The stent’s length = 15-30 mm and ≥30 mm reveals the presence of an expanded atherosclerotic process, the substrate of which is constituted by the endothelial dysfunction, this being confirmed by the low preprocedural level of NO. The stent implantation procedure induced the accentuation of endothelial dysfunction, and the 12-month nebivolol treatment favored the increase of NO serum concentraon in all groups by 24.9% vs the reference pattern and by 73.3% vs baseline.

European Heart JournalVol. 45(Supplement_1)
Grigore T. Popa University of Medicine and Pharmacy (RO), Institute of Cardiology (RU)
Openalex Percentile: Top 66%
Cardiovascular Health and Disease Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.