Long-term outcomes of aortic stenosis patients with different flow/gradient patterns undergoing transcatheter aortic valve implantation

Abstract Background Few data exist on the comparative long-term outcomes of severe aortic stenosis (AS) patients with different flow-gradient patterns undergoing transcatheter aortic valve implantation (TAVI). This study sought to evaluate the impact of the pre-TAVI flow-gradient pattern on long-term clinical outcomes after TAVI. Methods Consecutive patients with severe AS undergoing TAVI in our institution were screened and prospectively enrolled. Patients were divided into four subgroups according to pre-TAVI flow/gradient pattern: (i) low flow—low gradient (LF-LG): stroke volume indexed (SVi) ≤ 35 mL/m2 and mean gradient (MG) < 40 mmHg); (ii) normal flow—low gradient (NF-LG): SVi > 35 mL/m2 and MG < 40 mmHg; (iii) low flow—high gradient (LF-HG): Svi 35 mL/m2 and MG ≥ 40 mmHg and (iv) normal flow—high gradient (NF-HG): SVi > 35 mL/m2 and MG ≥ 40 mmHg. Clinical follow-up was obtained at 12 months, and yearly thereafter until 5-year follow-up was complete for all patients. Results A total of 272 patients with complete echocardiographic and clinical follow-up were included in our analysis. Their mean age was 80 ± 7 years and the majority of patients (N = 138, 50.8%) were women. 62 patients (22.8% of the study population) were distributed in the LF-LG group, 98 patients (36%) were LF-HG patients, 95 patients (34.9%) were NF-HG, and 17 patients (6.3%) were NF-LG. There was a greater prevalence of comorbidities among LF-LG AS patients. One-year all-cause mortality differed significantly between the four subgroups of AS patients (log-rank p: 0.022) and was more prevalent among LF-LG patients (25.8%) compared to LF-HG (11.3%), NF-HG (6.3%) and NF-LG patients (18.8%). At 5-year follow-up, global mortality remained persistently higher among LF-LG patients (64.5%) compared to LF-HG (47.9%), NF-HG (42.9%), and NF-LG patients (58.8%) (log-rank p: 0.029) (Figure 1). At multivariable Cox hazard regression analysis, baseline SVi (HR: 0.951, 95% C.I.; 0.918–0.984), the presence of at least moderate tricuspid regurgitation at baseline (HR: 3.091, 95% C.I: 1.645–5.809) and at least moderate paravalvular leak (PVL) post-TAVI (HR: 1.456, 95% C.I.: 1.106–1.792) were significant independent predictors of late global mortality. Conclusions Patients with LF-LG AS have acceptable 1-year outcomes, but exhibit exceedingly high 5-year mortality following TAVI. The presence of low transvalvular flow and at least moderate tricuspid regurgitation at baseline and significant paravalvular leak post-TAVI were associated with poorer long-term outcomes in the entire cohort of AS patients.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1835
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-term outcomes of aortic stenosis patients with different flow/gradient patterns undergoing transcatheter aortic valve implantation

Konstantinos P. Toutouzas, George Latsios, Maria Xanthopoulou, Anastasiοs Apostolos et al.
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Long-term outcomes of aortic stenosis patients with different flow/gradient patterns undergoing transcatheter aortic valve implantation

Konstantinos P. Toutouzas, George Latsios, Maria Xanthopoulou, Anastasiοs Apostolos, Maria I. Drakopoulou, P Toskas, Konstantinos Stathogiannis, G Oikonomou, Maria Karmpalioti, N Ktenopoulos, C Simopoulou, Andreas Synetos, C Tsioufis
article en

Abstract

Abstract Background Few data exist on the comparative long-term outcomes of severe aortic stenosis (AS) patients with different flow-gradient patterns undergoing transcatheter aortic valve implantation (TAVI). This study sought to evaluate the impact of the pre-TAVI flow-gradient pattern on long-term clinical outcomes after TAVI. Methods Consecutive patients with severe AS undergoing TAVI in our institution were screened and prospectively enrolled. Patients were divided into four subgroups according to pre-TAVI flow/gradient pattern: (i) low flow—low gradient (LF-LG): stroke volume indexed (SVi) ≤ 35 mL/m2 and mean gradient (MG) < 40 mmHg); (ii) normal flow—low gradient (NF-LG): SVi > 35 mL/m2 and MG < 40 mmHg; (iii) low flow—high gradient (LF-HG): Svi 35 mL/m2 and MG ≥ 40 mmHg and (iv) normal flow—high gradient (NF-HG): SVi > 35 mL/m2 and MG ≥ 40 mmHg. Clinical follow-up was obtained at 12 months, and yearly thereafter until 5-year follow-up was complete for all patients. Results A total of 272 patients with complete echocardiographic and clinical follow-up were included in our analysis. Their mean age was 80 ± 7 years and the majority of patients (N = 138, 50.8%) were women. 62 patients (22.8% of the study population) were distributed in the LF-LG group, 98 patients (36%) were LF-HG patients, 95 patients (34.9%) were NF-HG, and 17 patients (6.3%) were NF-LG. There was a greater prevalence of comorbidities among LF-LG AS patients. One-year all-cause mortality differed significantly between the four subgroups of AS patients (log-rank p: 0.022) and was more prevalent among LF-LG patients (25.8%) compared to LF-HG (11.3%), NF-HG (6.3%) and NF-LG patients (18.8%). At 5-year follow-up, global mortality remained persistently higher among LF-LG patients (64.5%) compared to LF-HG (47.9%), NF-HG (42.9%), and NF-LG patients (58.8%) (log-rank p: 0.029) (Figure 1). At multivariable Cox hazard regression analysis, baseline SVi (HR: 0.951, 95% C.I.; 0.918–0.984), the presence of at least moderate tricuspid regurgitation at baseline (HR: 3.091, 95% C.I: 1.645–5.809) and at least moderate paravalvular leak (PVL) post-TAVI (HR: 1.456, 95% C.I.: 1.106–1.792) were significant independent predictors of late global mortality. Conclusions Patients with LF-LG AS have acceptable 1-year outcomes, but exhibit exceedingly high 5-year mortality following TAVI. The presence of low transvalvular flow and at least moderate tricuspid regurgitation at baseline and significant paravalvular leak post-TAVI were associated with poorer long-term outcomes in the entire cohort of AS patients.

European Heart JournalVol. 45(Supplement_1)
Hippocration General Hospital (GR)
Openalex Percentile: Top 66%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.