Feasibility and early outcomes of atrial septal defect prostheses use for percutaneous closure of widely open patent foramen ovale

Abstract Background The efficient closure of patent foramen ovale (PFO) with short canal length and large width, usually associated with atrial septal aneurysm (ASA), remains challenging. These cases frequently require the use of larger PFO devices to avoid the risk of device embolism at the cost of a higher rate of residual shunting, mostly due to interdisk spacing. The use of atrial septal defect (ASD) prosthesis could be useful in these patients. Purpose To describe feasibility and early outcomes of the use of ASD device for percutaneous closure of widely open PFO representing an "ASD-like anatomy". Methods Since January 2022 in a high volume French university center, we started to use ASD device for percutaneous closure of selected cases of PFO with complex anatomy as mainly defined by a sheathed width of PFO ≥ 5 mm and sheathed canal length ≤ 10 mm (Figure 1) facing major per-operative residual shunt with PFO prostheses in some patients. In addition to the descriptive results, we compared this ASD device subgroup with a cohort of patients with similar anatomy but previously treated in our center with PFO device. All available transesophageal echocardiography (TEE) examinations were reviewed. The main objective was to describe the feasibility of the procedure (success and safety), the secondary endpoint was immediate post-procedural moderate to severe residual right-to-left shunt (RLS), defined as ≥ 10 bubbles in the left atrium within 3 cardiac cycles after transfemoral agitated saline injection. Results A total of 65 patients was treated with ASD devices, procedural success was achieved in all patients with a low rate (4,2%) of intrahospital complications (two supraventricular arrythmia, one anaphylactic shock and one minor laryngeal injury) and without device embolism. As compared with a cohort of 127 patients of similar anatomy treated with PFO device, patients in the ASD device group had more complex characteristics especially higher mean sheathed PFO width and shorter mean sheathed PFO canal length. Immediate post-procedural residual moderate to severe RLS did not differ significatively between groups (Table 1). No or minimal shunting was observed in 91% and 92% of cases (p=NS) but the three patients with severe RLS were all in the PFO device group. Conclusion Percutaneous closure of "ASD-like" PFO with ASD prostheses is feasible and safe. Larger studies and longer follow-ups are now required to confirm the expected improved sealing effect with this strategy.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2478
Citations
1
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility and early outcomes of atrial septal defect prostheses use for percutaneous closure of widely open patent foramen ovale

G Montalescot, Paul Guedeney, Nadjib Hammoudi, T Wallet et al.
1 citations
European Heart Journal
Cardiovascular and Diving-Related Complications
0.42
article

Feasibility and early outcomes of atrial septal defect prostheses use for percutaneous closure of widely open patent foramen ovale

G Montalescot, Paul Guedeney, Nadjib Hammoudi, T Wallet, Johanne Silvain, Perrine Devos, N Bouziri, Michel Zeitouni, Niki Procopi, M. Dupuy
article en
1 citations

Abstract

Abstract Background The efficient closure of patent foramen ovale (PFO) with short canal length and large width, usually associated with atrial septal aneurysm (ASA), remains challenging. These cases frequently require the use of larger PFO devices to avoid the risk of device embolism at the cost of a higher rate of residual shunting, mostly due to interdisk spacing. The use of atrial septal defect (ASD) prosthesis could be useful in these patients. Purpose To describe feasibility and early outcomes of the use of ASD device for percutaneous closure of widely open PFO representing an "ASD-like anatomy". Methods Since January 2022 in a high volume French university center, we started to use ASD device for percutaneous closure of selected cases of PFO with complex anatomy as mainly defined by a sheathed width of PFO ≥ 5 mm and sheathed canal length ≤ 10 mm (Figure 1) facing major per-operative residual shunt with PFO prostheses in some patients. In addition to the descriptive results, we compared this ASD device subgroup with a cohort of patients with similar anatomy but previously treated in our center with PFO device. All available transesophageal echocardiography (TEE) examinations were reviewed. The main objective was to describe the feasibility of the procedure (success and safety), the secondary endpoint was immediate post-procedural moderate to severe residual right-to-left shunt (RLS), defined as ≥ 10 bubbles in the left atrium within 3 cardiac cycles after transfemoral agitated saline injection. Results A total of 65 patients was treated with ASD devices, procedural success was achieved in all patients with a low rate (4,2%) of intrahospital complications (two supraventricular arrythmia, one anaphylactic shock and one minor laryngeal injury) and without device embolism. As compared with a cohort of 127 patients of similar anatomy treated with PFO device, patients in the ASD device group had more complex characteristics especially higher mean sheathed PFO width and shorter mean sheathed PFO canal length. Immediate post-procedural residual moderate to severe RLS did not differ significatively between groups (Table 1). No or minimal shunting was observed in 91% and 92% of cases (p=NS) but the three patients with severe RLS were all in the PFO device group. Conclusion Percutaneous closure of "ASD-like" PFO with ASD prostheses is feasible and safe. Larger studies and longer follow-ups are now required to confirm the expected improved sealing effect with this strategy.

European Heart JournalVol. 45(Supplement_1)
Sorbonne Université (FR), Pitié-Salpêtrière Hospital (FR)
Good health and well-being
Openalex Percentile: Top 31%
Cardiovascular and Diving-Related Complications
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.