Procedure-related radiation and contrast use during TAVI procedures with balloon-expandable versus self-expanding devices

Abstract Background Transcatheter aortic valve implantation (TAVI) procedures show some fundamental differences, depending on the use of balloon-expandable (BEV) or self-expanding (SEV) devices. We aimed to assess, how it translates into contrast use and radiation exposure. Methods From five high volume European centers consecutive patients were included, who underwent transfemoral TAVI procedure. Patient- and procedural characteristics were recorded and compared in relation to the used TAVI device. Results In total 3131 patients were included. 53% were male and the mean age was 80±9 years. 1273 (41%) patients were treated with BEV, while 1858 (59%) with a SEV system. Patients, receiving SEV were older (81±9 vs 79±9 years, respectively; p<0.01) and were more often females (57% vs 33%, respectively; p<0.01). There was also a trend for less peripheral artery disease (14% vs 17%, respectively; p=0.06). Overall total radiation time was 15±9 min., that was markedly shorter for BEV than for SEV (13±8 vs. 17±10 min., respectively; p<0.01). On average 130±65 mL contrast media was used, that was less for BEV than for SEV (104±52 vs. 148±67 mL, respectively; p<0.01) In terms of contrast use, retrievable- and non-retrievable SEVs were comparable (148±71 vs. 146±63 mL, respectively; p=0.41), but both markedly higher, than for BEVs (p<0.01 for both). Non-retrievable SEVs required less radiation (14±7 vs. 18±10 mins, respectively; p<0.01), but still markedly more than BEVs (p<0.01). Conclusion TAVI procedures with BEV require shorter radiation exposure for the team and markedly less contrast, than with SEV. This might be reasonable to consider during patient-tailored procedure planning.Radiation and contrast usage during TAVI

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.2443
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Procedure-related radiation and contrast use during TAVI procedures with balloon-expandable versus self-expanding devices

Judit Andréka, Michael Adamaszek, Alexander Wolf, Robertas Pranevičius et al.
European Heart Journal
Cardiac Valve Diseases and Treatments
article

Procedure-related radiation and contrast use during TAVI procedures with balloon-expandable versus self-expanding devices

Judit Andréka, Michael Adamaszek, Alexander Wolf, Robertas Pranevičius, Albrecht Schmidt, Ander Regueiro, S Schnur, C. N. Stark, Pierre Deharo, Salvatore Brugaletta, Heiko Bugger, Dan Prunea, Gábor G. Tóth, T. Cuisset
article en

Abstract

Abstract Background Transcatheter aortic valve implantation (TAVI) procedures show some fundamental differences, depending on the use of balloon-expandable (BEV) or self-expanding (SEV) devices. We aimed to assess, how it translates into contrast use and radiation exposure. Methods From five high volume European centers consecutive patients were included, who underwent transfemoral TAVI procedure. Patient- and procedural characteristics were recorded and compared in relation to the used TAVI device. Results In total 3131 patients were included. 53% were male and the mean age was 80±9 years. 1273 (41%) patients were treated with BEV, while 1858 (59%) with a SEV system. Patients, receiving SEV were older (81±9 vs 79±9 years, respectively; p<0.01) and were more often females (57% vs 33%, respectively; p<0.01). There was also a trend for less peripheral artery disease (14% vs 17%, respectively; p=0.06). Overall total radiation time was 15±9 min., that was markedly shorter for BEV than for SEV (13±8 vs. 17±10 min., respectively; p<0.01). On average 130±65 mL contrast media was used, that was less for BEV than for SEV (104±52 vs. 148±67 mL, respectively; p<0.01) In terms of contrast use, retrievable- and non-retrievable SEVs were comparable (148±71 vs. 146±63 mL, respectively; p=0.41), but both markedly higher, than for BEVs (p<0.01 for both). Non-retrievable SEVs required less radiation (14±7 vs. 18±10 mins, respectively; p<0.01), but still markedly more than BEVs (p<0.01). Conclusion TAVI procedures with BEV require shorter radiation exposure for the team and markedly less contrast, than with SEV. This might be reasonable to consider during patient-tailored procedure planning.Radiation and contrast usage during TAVI

European Heart JournalVol. 45(Supplement_1)
Lithuanian University of Health Sciences (LT), Medical University of Graz (AT), St. Elisabeth-Hospital Bochum (DE), Hospital Clínic de Barcelona (ES), Hôpital de la Timone (FR)
Openalex Percentile: Top 66%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.