TAVI-related vascular access complications: are Viabahn stents a good option?
Abstract Background Vascular access complications (VACs) remain one of the biggest challenges when performing transcatheter aortic valve implantation (TAVI). Historically, concerns regarding stent placement in flexing points have been a deterrent to the percutaneous treatment of VACs, due to the potential development of claudication over time. The Viabahn stent, being a covered stent that offers flexibility and conformability, may be well-suited for deployment in these anatomies. Purpose This study aimed to evaluate the safety and efficacy of the iliofemoral Viabahn stenting for treating TAVI-related VACs. Methods Retrospective analysis of patients submitted to Viabahn stenting in the iliofemoral sector for TAVI-related VACs in a single tertiary centre between January 2017 and October 2023. Baseline characteristics, procedure data and complications were noted according to the Valve Academic Research Consortium-2. Results A total of 722 patients were submitted to transfemoral TAVI during the study period. Of these, 25 (3.6%) underwent Viabahn stenting to treat TAVI-related VACs and were included in this study. Patient mean age was 82.1±6.13 years, 61.2% were male. At the baseline, patients had a mean Euroscore II of 2.73±1.91. A unilateral access approach was used in 40% of cases. The median size of the main access sheath was 14 Fr [IQ 14-16], and the closure devices deployed were Manta® in 72%, and Perclose® in 28%. The Viabahn stent treated different types of VACS, including vessel rupture in 56%, acute dissection in 28% (12% with no antegrade flow), and failed sealing in 16%. The complicated artery was the common femoral in 82%, and the external iliac in 18%. Percutaneous treatment with Viabahn stenting was successful in 92% of cases. In two cases (8%), one of acute occlusion and one of vessel rupture, vascular surgery was required. During the hospital stay, there were no further vascular or hemorrhagic complications. After a mean follow-up of 15 months, 20% of patients were evaluated by Doppler which showed no signs of restenosis or stent complications. Only one patient experienced lower limb claudication at 1 year due to stent restenosis detected in the CT scan, which was managed with medical therapy. There were no other adverse vascular events during follow-up. Conclusion Our study suggests that Viabahn stenting emerges as a valuable therapeutic option, ensuring long-term safety and efficacy, in the complex realm of TAVI-related vascular complications.
Authors
- A Grazina (ORCID: https://orcid.org/0000-0003-0748-0046)
- Bernardo Corrêa de Almeida Teixeira (ORCID: https://orcid.org/0000-0003-4769-6562)
- Leonardo Fiúsa de Morais (ORCID: https://orcid.org/0000-0002-3368-4213)
- Rúben Ramos (ORCID: https://orcid.org/0000-0003-0736-3878)
- A Castelo (ORCID: https://orcid.org/0000-0002-5117-7151)
- R Teixeira (ORCID: https://orcid.org/0000-0001-8358-861X)
- Duarte Cacela (ORCID: https://orcid.org/0009-0007-6597-5633)
- António José Fiarresga (ORCID: https://orcid.org/0000-0003-1912-4989)
- Inês Rodrigues (ORCID: https://orcid.org/0000-0002-2240-428X)
- T Mendonca (ORCID: https://orcid.org/0009-0009-2729-6597)
- R Cruz Ferreira
- A Ferreira (ORCID: https://orcid.org/0000-0002-9965-2265)
Institutions
- Hospital de Santa Marta (PT)
Publication Details
- Journal
- European Heart Journal
- Published
- 2024-10-01
- DOI
- https://doi.org/10.1093/eurheartj/ehae666.2441
- Primary Topic
- Vascular Procedures and Complications
- Type
- article
- Field-Weighted Citation Impact
- 0.00