AI-enabled cardiac chambers volumetry in non-contrast coronary artery calcium CT scans vs. contrast-enhanced coronary CT angiography scans in the same patients

Abstract Introduction We have developed an AI-enabled automated volumetry of cardiac chambers (AutoChamber) that works both on non-contrast ECG-gated cardiac CT scans used for coronary artery calcium (CAC) score, and non-contrast non-gated lung cancer screening CT scans. We have recently reported the agreement between AutoChamber measurements vs cardiac MRI measurements. Here we report AutoChamber results on non-contrast CAC scans and contrast enhanced coronary CT angiography (CTA). Methods We have obtained CT images from a previously published study in which 131 cases underwent non-contrast CAC and contrast enhanced CCTA at research institute. The cases consisted of 52.4% women with ages 55.0 ± 10.1 years. The cardiac chambers volume in 131 cases of contrast enhanced CCTA were measured using automated chamber volumetry by Philips Brilliance Volume v 4.5; Philips Healthcare. Results The correlations between Philips’ automated chamber volumetry in contrast enhanced CCTA scans versus AutoChamber automated volumetry in non-contrast CAC scans for left atrium (LA), left ventricle (LV), right atrium (RA), right ventricle (RV), and left ventricular wall (LVW) volume were 0.73, 0.65, 0.85, 0.93, 0.90, respectively (P for all <0.01). Conclusion AI-enabled AutoChamber volumetry based on non-contrast cardiac scans is feasible, and correlates reasonably well with contrast-enhanced cardiac CT scans. Further studies are warranted to reproduce these results and explore the add-on value of AutoChamber to CAC scans.

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.206
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AI-enabled cardiac chambers volumetry in non-contrast coronary artery calcium CT scans vs. contrast-enhanced coronary CT angiography scans in the same patients

Morteza Naghavi, S. S. Mao, Cornelia Henschke, David F. Yankelevitz et al.
European Heart Journal
Advanced X-ray and CT Imaging
article

AI-enabled cardiac chambers volumetry in non-contrast coronary artery calcium CT scans vs. contrast-enhanced coronary CT angiography scans in the same patients

Morteza Naghavi, S. S. Mao, Cornelia Henschke, David F. Yankelevitz, Anthony P. Reeves, Matthew Jay Budoff, Kyle Atlas, Chenyu Zhang
article en

Abstract

Abstract Introduction We have developed an AI-enabled automated volumetry of cardiac chambers (AutoChamber) that works both on non-contrast ECG-gated cardiac CT scans used for coronary artery calcium (CAC) score, and non-contrast non-gated lung cancer screening CT scans. We have recently reported the agreement between AutoChamber measurements vs cardiac MRI measurements. Here we report AutoChamber results on non-contrast CAC scans and contrast enhanced coronary CT angiography (CTA). Methods We have obtained CT images from a previously published study in which 131 cases underwent non-contrast CAC and contrast enhanced CCTA at research institute. The cases consisted of 52.4% women with ages 55.0 ± 10.1 years. The cardiac chambers volume in 131 cases of contrast enhanced CCTA were measured using automated chamber volumetry by Philips Brilliance Volume v 4.5; Philips Healthcare. Results The correlations between Philips’ automated chamber volumetry in contrast enhanced CCTA scans versus AutoChamber automated volumetry in non-contrast CAC scans for left atrium (LA), left ventricle (LV), right atrium (RA), right ventricle (RV), and left ventricular wall (LVW) volume were 0.73, 0.65, 0.85, 0.93, 0.90, respectively (P for all <0.01). Conclusion AI-enabled AutoChamber volumetry based on non-contrast cardiac scans is feasible, and correlates reasonably well with contrast-enhanced cardiac CT scans. Further studies are warranted to reproduce these results and explore the add-on value of AutoChamber to CAC scans.

European Heart JournalVol. 45(Supplement_1)
Cornell University (US), Mount Sinai Hospital (US)
Openalex Percentile: Top 83%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.