Clinical features of infective endocarditis affecting cardiac implantable electronic devices

Abstract Introduction Infective endocarditis (IE) is a serious condition with high rates of serious complications and mortality. Furthermore, implantation of cardiac electronic devices (peacemakers, ICD, CRT) has been increasing in recent years, with technique-associated infections being one of the main adverse events. Our goal was to analise clinical features of IE as associated with cardiac implantable electronic devices (IE-CIED) and its prognostic impact. Methods Prospective study of a cohort of patients diagnosed with IE in our centre from 1987 to 2022. A comparative analysis was performed between patients with IE not associated with cardiac implantable electronic devices (group 1) and those who did (group 2). Clinical, microbiological, echocardiographic and therapeutic variables were analysed and the prognostic impact was evaluated in terms of mortality. Results 569 patients were analysed, of which 540 (94,9%) belonged to group 1, while 29 (5,1%) belonged to group 2. The mean age was higher in group 2 (65,1 years ±12,9 vs 55,7 years ± 18,7; p=0,011) with male predominance in both populations (67.5% overall). Patients with IE-CIED had a higher proportion of staphylococcus aureus (48.3% vs 19.7%; p<0.001) and staphylococcus epidermidis (34.5% vs 15.6%; p<0.001) infections; nosohusial endocarditis (56.5% vs 20.9%; p<0.001); and underlying heart disease (89.7% vs 67.3%; p=0.012). Furthermore, these patients had a higher proportion of tricuspid valve involvement (18.2% vs 81.8%; p<0.001). Regarding the approach, a higher percentage of surgery was performed in patients with IE-CIED (75.9% vs52.7%; p=0.015). On the other hand, patients with IE not associated to cardiac implantable electronic devices had a higher prevalence of cardiac complications (51.5%vs25.7%;p=0.003), defined as valvular rupture or perforation, pseudoaneurysm, abscess or intracardiac fistula; and central nervous system complications (17.2%vs2.9%;p=0.29). No significative differences were found in terms of echocardiographic findings compatibles with IE, nor were there any differences in severe complications or early, late or total mort ality. Conclusions Infective endocarditis affecting cardiac implantable electronic devices is associated to higher prevalence of staphylococci, underlying heart disease and less involvement of the left heart chambers. Surgery was used to a greater extent in this patients. This entity does not imply a worse prognosis in terms of severe complications or mortality.Table 1.Proportion of IE-CIEDTable 2.Microbiology, mortality

Authors

Institutions

Publication Details

Journal
European Heart Journal
Published
2024-10-01
DOI
https://doi.org/10.1093/eurheartj/ehae666.1974
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical features of infective endocarditis affecting cardiac implantable electronic devices

Rafael González Manzanares, Ana Almodóvar, Liliana Mesa, A Roldan Guerra et al.
1 citations
European Heart Journal
Cardiac pacing and defibrillation studies
0.40
article

Clinical features of infective endocarditis affecting cardiac implantable electronic devices

Rafael González Manzanares, Ana Almodóvar, Liliana Mesa, A Roldan Guerra, José López Aguilera, N. Cano, C Urbano Sanchez, Manuel Crespín Crespín, Manuel Pan, Martín Ruiz Ortiz, F Esteban Martinez, D Mesa Rubio, Mónica Delgado Ortega
article en
1 citations

Abstract

Abstract Introduction Infective endocarditis (IE) is a serious condition with high rates of serious complications and mortality. Furthermore, implantation of cardiac electronic devices (peacemakers, ICD, CRT) has been increasing in recent years, with technique-associated infections being one of the main adverse events. Our goal was to analise clinical features of IE as associated with cardiac implantable electronic devices (IE-CIED) and its prognostic impact. Methods Prospective study of a cohort of patients diagnosed with IE in our centre from 1987 to 2022. A comparative analysis was performed between patients with IE not associated with cardiac implantable electronic devices (group 1) and those who did (group 2). Clinical, microbiological, echocardiographic and therapeutic variables were analysed and the prognostic impact was evaluated in terms of mortality. Results 569 patients were analysed, of which 540 (94,9%) belonged to group 1, while 29 (5,1%) belonged to group 2. The mean age was higher in group 2 (65,1 years ±12,9 vs 55,7 years ± 18,7; p=0,011) with male predominance in both populations (67.5% overall). Patients with IE-CIED had a higher proportion of staphylococcus aureus (48.3% vs 19.7%; p<0.001) and staphylococcus epidermidis (34.5% vs 15.6%; p<0.001) infections; nosohusial endocarditis (56.5% vs 20.9%; p<0.001); and underlying heart disease (89.7% vs 67.3%; p=0.012). Furthermore, these patients had a higher proportion of tricuspid valve involvement (18.2% vs 81.8%; p<0.001). Regarding the approach, a higher percentage of surgery was performed in patients with IE-CIED (75.9% vs52.7%; p=0.015). On the other hand, patients with IE not associated to cardiac implantable electronic devices had a higher prevalence of cardiac complications (51.5%vs25.7%;p=0.003), defined as valvular rupture or perforation, pseudoaneurysm, abscess or intracardiac fistula; and central nervous system complications (17.2%vs2.9%;p=0.29). No significative differences were found in terms of echocardiographic findings compatibles with IE, nor were there any differences in severe complications or early, late or total mort ality. Conclusions Infective endocarditis affecting cardiac implantable electronic devices is associated to higher prevalence of staphylococci, underlying heart disease and less involvement of the left heart chambers. Surgery was used to a greater extent in this patients. This entity does not imply a worse prognosis in terms of severe complications or mortality.Table 1.Proportion of IE-CIEDTable 2.Microbiology, mortality

European Heart JournalVol. 45(Supplement_1)
Instituto Maimónides de Investigación Biomédica de Córdoba (ES), Hospital Universitario Reina Sofía (ES)
Openalex Percentile: Top 31%
Cardiac pacing and defibrillation studies
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.